Search results for "biosensor"
showing 10 items of 236 documents
Multicomponent bionanocomposites based on clay nanoarchitectures for electrochemical devices
2019
[EN] Based on the unique ability of defibrillated sepiolite (SEP) to form stable and homogeneous colloidal dispersions of diverse types of nanoparticles in aqueous media under ultrasonication, multicomponent conductive nanoarchitectured materials integrating halloysite nanotubes (HNTs), graphene nanoplatelets (GNPs) and chitosan (CHI) have been developed. The resulting nanohybrid suspensions could be easily formed into films or foams, where each individual component plays a critical role in the biocomposite: HNTs act as nanocontainers for bioactive species, GNPs provide electrical conductivity (enhanced by doping with MWCNTs) and, the CHI polymer matrix introduces mechanical and membrane pr…
Biosensor Analysis of β2-Glycoprotein I–Reactive Autoantibodies: Evidence for Isotype-Specific Binding and Differentiation of Pathogenic from Infecti…
2007
Abstract Background: For the laboratory diagnosis of the antiphospholipid syndrome (APS) we developed a biosensor with the ability to distinguish between disease-relevant anti-β2-glycoprotein I (β2GPI) autoantibodies (anti-β2GPI) and pathogen-specific β2GPI cross-reactive antibodies that occur transiently during infections. Methods: We used a surface plasmon resonance (SPR) biosensor device. For the detection of anti-β2GPI in serum samples, affinity-purified human β2GPI was covalently attached to a functionalized n-alkanethiol self-assembling monolayer on the biosensor chip. After verifying the specificity of the biosensor system with a panel of monoclonal antibodies to β2GPI, we analyzed s…
Changes in surface stress at the liquid/solid interface measured with a microcantilever
2000
Abstract The bending of microfabricated silicon nitride cantilevers was used to determine surface stress changes at solid–liquid interfaces. The radius of curvature of the bent cantilever is directly proportional to changes in the differential surface stress between its opposite sides. To demonstrate the possibilities and limitations of the technique, cantilevers coated on both sides with gold and densely packed monolayers of different thiols were put in a constant flow of aqueous electrolyte solution and the deflection was measured using a optical lever technique. Changes in the surface stress for the different thiol monolayers due to specific proton adsorption are presented. Possible appl…
Characteristic ERK1/2 signaling dynamics distinguishes necroptosis from apoptosis
2021
International audience; ERK1/2 involvement in cell death remains unclear, although many studies have demonstrated the importance of ERK1/2 dynamics in determining cellular re- sponses. To untangle how ERK1/2 contributes to two cell death programs, we investigated ERK1/2 signaling dynamics during hFasL-induced apoptosis and TNF-induced necroptosis in L929 cells. We observed that ERK1/2 inhibition sensi- tizes cells to apoptosis while delaying necroptosis. By monitoring ERK1/2 activity by live-cell imaging using an improved ERK1/2 biosensor (EKAR4.0), we reported differential ERK1/2 signaling dynamics between cell survival, apoptosis, and nec- roptosis. We also decrypted a temporally shifted …
Switchable assembly of stable, ordered molecular layers
1999
Bisamidines can be assembled on self-assembled monolayers of mercaptoalkanoic acids on gold to form stable and ordered but pH-switchable layers (see diagram). At basic pH the layers are stable and charge selective towards charged surfactants and plasma proteins. The system can potentially be used to reversibly introduce new surface properties for given applications that use one single substrate.
Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor.
2003
An electrochemical methodology for bio-molecule sensing using an array of well-defined nanostructures is presented. We describe the fabrication by e-beam lithography of nanoelectrodes consisting of a 100 micro m x 50 micro m area containing interdigitated electrodes of 100 nm in width and interelectrode distance of 200 nm. Sensitivity and response time of the nanoelectrodes are compared to the responses of macro- and microelectrodes. The specificity of the sensor is studied by modifying the gold electrodes with DNA. The technique enables to characterize both single and double-stranded DNA of 15 nucleotides. A special electrochemical cell is adapted to control the temperature and measure the…
Scanning Force Microscopy of Artificial Membranes
2002
Visualization of biological membranes by scanning force microscopy (SFM) has tremendously improved the current understanding of protein ‐ lipid interactions under physiological conditions. SFM is the only tool to directly image processes on surfaces in aqueous solution at molecular resolution. Besides being a supportive means to confirm results on lipid phases and domains obtained from fluorescence spectroscopy, calorimetry, and X-ray crystallography, SFM has contributed distinct aspects on the formation of 2D crystals of various membrane-confined proteins and morphological changes of membranes due to the interaction of peptides and proteins. This review will focus on recent results in SFM …
Solution Processed Micro- and Nano-Bioarrays for Multiplexed Biosensing
2012
This Feature article reports on solution dispensing methodologies which enable the realization of multiplexed arrays at the micro- and nanoscale for relevant biosensing applications such as drug screening or cellular chips.
Novel biosensor-based analytic device for the detection of anti-double-stranded DNA antibodies.
2007
AbstractBackground: Patients with systemic lupus erythematosus (SLE) develop a wide variety of serologic manifestations, including double-stranded DNA autoantibodies (anti-dsDNA). The determination of the potentially pathogenic autoantibodies is diagnostically relevant.Methods: We developed a novel surface plasmon resonance (SPR) biosensor chip for studies of dsDNA and anti-dsDNA binding. A synthetic oligonucleotide was coupled to biotinylated human transferrin, hybridized with the complementary antistrand, and ligated with a human recombinant dsDNA fragment 233 bp in length. After surface immobilization of this antigenic construct, diluted sera from SLE patients and healthy donors were ana…
Optical systems for non-invasive cardiovascular biosensing
2005
Three portable prototype devices for cardiovascular biosensing based on reflection-type photoplethysmography (PPG) principle have been designed and clinically tested. The single-channel PPG finger sensor provides real-time measurements with fast calculation of the mean single-period PPG signal shape ("cardiovascular fingerprint", potentially useful for recognition). The dual-channel PPG system gives additional possibility to monitor on-line the arterial pulse wave transit time and its responses to physical exercises. The four-channel PPG system proved to be applicable for fast detection of cardiovascular pathologies, e.g. arterial occlusions in extremities. Design principles and software al…