Search results for "compounding"

showing 10 items of 112 documents

Process parameters of microsphere preparation based on propylene carbonate emulsion-precursors.

2020

This study aimed for a detailed understanding of the impact of different process parameters involved during celecoxib-loaded microsphere preparation based on propylene carbonate emulsion-precursors.Microspheres were prepared by a modified emulsification-solvent extraction method. Performed investigations included polymer solubility and viscosity, microsphere size, morphology and stability, propylene carbonate content as well as celecoxib solid state, content and release.Rough-walled round microspheres with sizes between 21 µm and 122 µm and an internal sponge-like structure filled with residual propylene carbonate (content between 1.9 ± 0.1% and 6.7 ± 0.5% w/w) were obtained. Encapsulation …

Materials sciencePolymersSurface PropertiesChemistry PharmaceuticalDrug CompoundingPharmaceutical ScienceBioengineering02 engineering and technologyPolypropylenes030226 pharmacology & pharmacyMicrosphere03 medical and health scienceschemistry.chemical_compound0302 clinical medicineColloid and Surface ChemistryLactic AcidPhysical and Theoretical ChemistryParticle SizeDrug CarriersCalorimetry Differential ScanningViscosityOrganic Chemistry021001 nanoscience & nanotechnologyMicrospheresPLGADrug LiberationchemistryChemical engineeringSolubilityCelecoxibScientific methodPropylene carbonateEmulsionMicroscopy Electron ScanningSolventsEmulsions0210 nano-technologyPolyglycolic AcidJournal of microencapsulation
researchProduct

Morphology, interfacial interaction, and thermal degradation of polycarbonate/MCM-41 (nano)composites

2017

ABSTRACTThis article reports on the morphology, interfacial interaction, thermal stability, and thermal degradation kinetics of polycarbonate (PC)/mesoporous silica (MCM-41) composites with various MCM-41 contents, prepared by melt compounding. The composites with low filler loadings (<0.3 wt%) maintained their transparency because of the well dispersed MCM-41 particles, but at higher filler loadings the composites lost their transparency due to the presence of agglomerates. The presence of agglomerates decreased the thermal stability of PC due to the reduced effectiveness of the particles to immobilize the polymer chains, free radicals, and volatile degradation products.

Mesoporous silica; nanocomposites; polycarbonate; structure–property relationship; thermal degradation; Analytical Chemistry; Chemical Engineering (all); Polymers and PlasticsMaterials sciencePolymers and PlasticsGeneral Chemical Engineering02 engineering and technologystructure–property relationship010402 general chemistry01 natural sciencesAnalytical ChemistryMCM-41nanocompositesChemical Engineering (all)Thermal stabilitythermal degradationPolycarbonateComposite materialchemistry.chemical_classificationNanocompositenanocompositePolymerMesoporous silica021001 nanoscience & nanotechnology0104 chemical sciencespolycarbonatechemistryAgglomerateCompoundingvisual_artvisual_art.visual_art_medium0210 nano-technologyMesoporous silicaInternational Journal of Polymer Analysis and Characterization
researchProduct

Evaluation of drug-polymer solubility curves through formal statistical analysis: comparison of preparation techniques.

2014

ABSTRACT: In this study, the influence of the preparation technique (ball milling, spray drying, and film casting) of a supersaturated amorphous dispersion on the quality of solubility determinations of indomethacin in polyvinylpyrrolidone was investigated by means of statistical analysis. After annealing of the amorphous dispersions above the crystallization temperature for 2 h, the solubility curve was derived from the glass transition temperature of the demixed material using the Gordon–Taylor relationship and fitting with the Flory–Huggins model. The study showed that the predicted solubility from the ball-milled mixtures was not consistent with those from spray drying and film casting,…

Models MolecularMaterials scienceHot TemperatureChemistry PharmaceuticalDrug CompoundingIndomethacinAnalytical chemistryPharmaceutical SciencemedicinePharmaceutic AidsSolubilitySupersaturationReproducibilityPolyvinylpyrrolidoneCalorimetry Differential ScanningAnti-Inflammatory Agents Non-SteroidalPovidoneReproducibility of ResultsCastingAmorphous solidChemical engineeringSolubilitySpray dryingEmulsionsGlass transitionPowder Diffractionmedicine.drugJournal of pharmaceutical sciences
researchProduct

EVA-montmorillonite nanocomposites: effect of processing condition

2004

The aim of this study is to examine the effect of the compounding apparatus and of processing conditions on the properties of an organoclay-poly[ethylene-co-(vinyl acetate)] (EVA) nanocomposite. The filled materials were prepared using either a discontinuous batch mixer, a single screw extruder, a counter rotating intermeshing twin-screw compounder or a corotating intermeshing twin-screw extruder. The characterization of the obtained nanocomposites was performed by XRD, thermogravimetry, mechanical and rheological measurements. The study has shown the possibility of producing nanocomposites based on EVA and a commercial organoclay (Cloisite 15A) by several mixing equipments. In fact all the…

NanocompositeMaterials sciencePolymers and PlasticsGeneral Chemical EngineeringOrganic ChemistryPlastics extrusionMineralogyThermogravimetrychemistry.chemical_compoundMontmorillonitechemistryCompoundingMaterials ChemistryVinyl acetateOrganoclayComposite materialElastic modulus
researchProduct

Nanoassemblies Based on Supramolecular Complexes of Nonionic Amphiphilic Cyclodextrin and Sorafenib as Effective Weapons to Kill Human HCC Cells

2015

Sorafenib (Sor), an effective chemiotherapeutic drug utilized against hepatocellular carcinoma (HOC), robustly interacts with nonionic amphiphilic cyclodextrin (aCD, SC6OH), forming, in aqueous solution, supramolecular complexes that behave as building blocks of highly water-dispersible colloidal nanoassemblies. SC6OH/Sor complex has been characterized by complementary spectroscopic techniques, such as UV-vis, steady-state fluorescence and anisotropy, resonance light scattering and H-1 NMR. The spectroscopic evidences and experiments carried out in the presence of an adamantane derivative, which competes with drug for CD cavity, agree with the entrapment of Sor in aCD, pointing out the role…

NiacinamideErythrocytesPolymers and PlasticsCell SurvivalAdamantaneDrug CompoundingSupramolecular chemistryBioengineeringNanotechnologyAdamantaneAntineoplastic AgentsBinding CompetitiveHemolysisAmphiphilic Cyclodextrins; Nanoparticles; Sorafenib; HCC cellsHCC cellsBiomaterialschemistry.chemical_compoundSurface-Active AgentsIn vivoCell Line TumorAmphiphileMaterials ChemistryHumanschemistry.chemical_classificationCyclodextrinsAqueous solutionCyclodextrinPhenylurea CompoundsSorafenibFluorescenceCombinatorial chemistrydigestive system diseasesNanostructuresBINDING INTERACTION THERAPY PHARMACOKINETICS BIOAVAILABILITY NANOPARTICLESDrug LiberationKineticsnanoassembliecyclodextrinchemistryDelayed-Action PreparationsProton NMRHepatocytes
researchProduct

Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media

2016

Purpose The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. Methods DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70–150 µm ( = DC bead M1) or bead size 100–300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml…

Non ionicChemistry PharmaceuticalDrug CompoundingContrast Media01 natural sciences03 medical and health scienceschemistry.chemical_compound0302 clinical medicineDrug StabilityMedicinePharmacology (medical)Chromatography High Pressure LiquidEpirubicinPolypropyleneDrug CarriersEpirubicin InjectionChromatographyDrug eluting beadsbusiness.industrySyringes010401 analytical chemistryMicrospheres0104 chemical sciencesOncologychemistry030220 oncology & carcinogenesisCompatibility (mechanics)PowdersbusinessEpirubicinmedicine.drugJournal of Oncology Pharmacy Practice
researchProduct

Designing robust immediate release tablet formulations avoiding food effects for BCS class 3 drugs

2019

Abstract Food induced viscosity in the gastrointestinal tract is reported to reduce the bioavailability of tablets containing BCS class 3 drugs, mainly by retarding their disintegration and dissolution of the active pharmaceutical ingredient. The role of formulation factors in minimizing this negative food effect is largely unknown. Combinations of disintegrants were studied together with soluble and insoluble fillers and trospium chloride as model drug substance. Different batches of tablets were compressed at 10 kN and 30 kN, by incorporating different combinations of croscarmellose sodium (CSS), cross-linked (CPD) and sodium starch glycolate (SSG) at low level i.e, 2% + 2% and high level…

NortropanesChemistry PharmaceuticalDrug CompoundingPharmaceutical Science02 engineering and technologyBenzilates030226 pharmacology & pharmacyExcipientsFood-Drug Interactions03 medical and health sciencesViscositychemistry.chemical_compound0302 clinical medicineFood scienceSolubilityLactoseDissolutionActive ingredientCroscarmellose sodiumViscosityChemistryGeneral Medicine021001 nanoscience & nanotechnologyBioavailabilityMicrocrystalline celluloseDrug LiberationSolubilityDrug Design0210 nano-technologyTabletsBiotechnologyEuropean Journal of Pharmaceutics and Biopharmaceutics
researchProduct

Extemporaneous formulations in Germany – relevance for everyday clinical practice

2017

Background Extemporaneous formulations broaden the spectrum of therapeutic options for topical treatment in particular and thus improve patient care. The latest amendment to the Regulation on the Operation of Pharmacies issued in 2012 brought about changes in prescribing and manufacturing practices. The aim of the present study was to assess the relevance of extemporaneous formulations in everyday clinical practice. Methods We used data from the German Institute for Drug Use Evaluation (DAPI) to analyze the prescribing practice for compounded preparations in Germany between the fourth quarter of 2011 and the third quarter of 2014. In doing so, we determined the total cost associated with ex…

Pharmaciesmedicine.medical_specialtybusiness.industryAdministration TopicalDrug CompoundingPharmacyDermatologyClinical Practice030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineAmbulatory careGermany030220 oncology & carcinogenesisFamily medicineHealth careHealth insuranceHumansRelevance (law)MedicineMedical prescriptionbusinessDrug use evaluationJDDG: Journal der Deutschen Dermatologischen Gesellschaft
researchProduct

In-use physicochemical and microbiological stability of biological parenteral products

2015

Pharmaceutical scientists in the biotechnology industry have traditionally focused on achieving acceptable shelf lives of drug products in their original, unopened product unit configuration (e.g., two years stored at 2–8 °C). However, it is now clear that stability considerations extend beyond

PharmacologyBiological ProductsBacteriabusiness.industryChemistry PharmaceuticalDrug CompoundingHealth PolicyProteinsBiotechnologyPharmaceutical SolutionsDrug StabilityHumansInfusions ParenteralBusinessBiochemical engineeringProduct (category theory)Drug ContaminationDrug PackagingBiotechnology industryAmerican Journal of Health-System Pharmacy
researchProduct

Relevance of air-to-liquid mass ratio effect on final granule properties of an Enalapril maleate formulation.

2011

In the production of enalapril maleate tablets, the granulation process is the most crucial step. Numerous variables are known to influence the fluid bed granulation process and thus the final granule quality. In this study a novel descriptor for the nozzle parameter "air-to-liquid mass ratio" is presented. Granules manufacturing processes were designed by application of statistical experimental design.The influence of the critical process parameter (CPP)--air-to-liquid mass ratio--on pharmaceutic properties of granules was studied. Air-to-liquid mass ratio can be considered as important variable influencing the droplet size of atomized liquid binder solution.A significant influence of air-…

PharmacologyChemistryAirChemistry PharmaceuticalDrug CompoundingOrganic ChemistryNozzleGranule (cell biology)Analytical chemistryPharmaceutical ScienceProcess variableMass ratioGranulationChemical engineeringEnalaprilEnalapril MaleateDrug DiscoveryParticle-size distributionParticle SizePowdersFluid Bed GranulationTabletsDrug development and industrial pharmacy
researchProduct