Search results for "cornea"
showing 10 items of 404 documents
Influence of Corneal Opacity on Intraocular Pressure Assessment in Patients with Lysosomal Storage Diseases
2017
Aims To investigate an influence of mucopolysaccharidosis (MPS)- and Morbus Fabry-associated corneal opacities on intraocular pressure (IOP) measurements and to evaluate the concordance of the different tonometry methods. Methods 25 MPS patients with or without corneal clouding, 25 Fabry patients with cornea verticillata ≥ grade 2 and 25 healthy age matched controls were prospectively included into this study. Outcome measures: Goldmann applanation tonometry (GAT); palpatory assessment of IOP; Goldmann-correlated intraocular pressure (IOPg), corneal-compensated intraocular pressure (IOPcc), corneal resistance factor (CRF) and corneal hysteresis (CH) assessed by Ocular Response Analyzer (ORA…
A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma
2014
Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…
The Heidelberg retina tomograph ancillary study to the European glaucoma prevention study: study design and baseline factors.
2013
Purpose: To describe the study design and baseline factors of the Heidelberg Retina Tomograph ancillary study within the EGPS. Furthermore, to examine the relationship between HRT optic disc topographic measurements and baseline demographic and ocular factors. Methods: Four hundred and eighty-nine ocular hypertensive participants were included. Each participant completed HRT imaging at least annually. The associations between HRT measurements and IOP, central corneal thickness (CCT), baseline photographic estimates of vertical CDR ratio (CDR), asymmetry between the two eyes in CDR ratio and baseline visual field indices were assessed using regression analysis. Results: Associations between …
Prevalence of corneal arcus and associated factors in a German population-Results from the Gutenberg Health Study.
2021
Purpose We aimed to determine the prevalence of corneal arcus and to identify associated factors in the general population of Germany. Methods The Gutenberg Health Study (GHS) is a population-based cohort study in Germany, which includes an ophthalmological assessment. Refraction, distance-corrected visual acuity, non-contact tonometry and anterior segment imaging were performed for the five-year follow-up examination. Anterior segment photographs were graded for the presence of corneal arcus. Prevalence estimates were computed, and multivariable logistic regression analysis was applied to determine associated factors for corneal arcus including sex, age, spherical equivalent, central corn…
Genome-wide analysis of multi-ancestry cohorts identifies new loci influencing intraocular pressure and susceptibility to glaucoma
2014
Elevated intraocular pressure (IOP) is an important risk factor in developing glaucoma, and variability in IOP might herald glaucomatous development or progression. We report the results of a genome-wide association study meta-analysis of 18 population cohorts from the International Glaucoma Genetics Consortium (IGGC), comprising 35,296 multi-ancestry participants for IOP. We confirm genetic association of known loci for IOP and primary open-angle glaucoma (POAG) and identify four new IOP-associated loci located on chromosome 3q25.31 within the FNDC3B gene (P = 4.19 x 10(-8) for rs6445055), two on chromosome 9 (P = 2.80 x 10(-11) for rs2472493 near ABCA1 and P = 6.39 x 10(-11) for rs8176693…
Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.
2017
Purpose: We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. Methods: A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a s…
Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.
2020
OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…
Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes
2009
Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…
Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted descemet stripping auto…
2013
During donor tissue preparation for Descemet stripping automated endothelial keratoplasty (DSAEK), either microkeratome or femtosecond laser can be used for intrastromal cutting. We compared morphological and functional outcomes after DSAEK using both cutting techniques.In this retrospective study, 22 uneventful DSAEK surgeries were reviewed. Eight donor corneas were prepared for DSAEK using the VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany). Fourteen corneas were processed using an Amadeus II microkeratome (Ziemer Ophthalmic Systems AG, Port, Switzerland). The postoperative best spectacle-corrected visual acuity was measured. Furthermore, corneal optical coherence tomogra…
Effects Of COOH-terminal tripeptide alpha-MSH (11-13) on corneal epithelial wound healing:role of nitric oxide
2006
It is known that alpha-melanocyte stimulating hormone (alpha-MSH) may exert anti-inflammatory effects and facilitate reparative processes in different tissues. The effective message sequence of alpha-MSH resides in the COOH-terminal tripeptide alpha-MSH(11-13). This study was undertaken to investigate the effects of topical administration of the COOH-terminal tripeptide sequence of alpha-MSH (alpha-MSH(11-13), KPV) on corneal epithelial wound healing in rabbits and the possible role of nitric oxide (NO) in these effects. The whole corneal epithelium was denuded in both eyes by mechanical abrasion. The area of the corneal epithelial defect was stained with fluorescein, photographed, and then…