Search results for "detection"

showing 10 items of 2543 documents

Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.

2019

A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…

AnalyteClinical Biochemistrypartition equilibriumUrine030226 pharmacology & pharmacy01 natural sciencesBiochemistryAnalytical Chemistrymicellar chromatographyMatrix (chemical analysis)03 medical and health scienceschemistry.chemical_compound0302 clinical medicineRivaroxabanLimit of Detectiondirect injectionHumansMicellesvalidationChromatographyElutionanticoagulant010401 analytical chemistryExtraction (chemistry)biological fluidReproducibility of ResultsCell BiologyGeneral MedicinePhosphate0104 chemical scienceschemistryMicellar liquid chromatographyPartition equilibriumLinear ModelsChromatography LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Affinity Sensors for the Diagnosis of COVID-19

2021

The coronavirus disease 2019 (COVID-19) outbreak caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was proclaimed a global pandemic in March 2020. Reducing the dissemination rate, in particular by tracking the infected people and their contacts, is the main instrument against infection spreading. Therefore, the creation and implementation of fast, reliable and responsive methods suitable for the diagnosis of COVID-19 are required. These needs can be fulfilled using affinity sensors, which differ in applied detection methods and markers that are generating analytical signals. Recently, nucleic acid hybridization, antigen-antibody interaction, and change of reactive oxyge…

AnalyteCoronavirus disease 2019 (COVID-19)Computer scienceimmune complexSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)lcsh:Mechanical engineering and machinerySARS-CoV-2 virus02 engineering and technologyReviewelectrochemical immunosensors03 medical and health sciencesCOVID-19 ; SARS-CoV-2 virus ; RNA analysis ; bioelectrochemistry ; biosensors ; electro- chemical immunosensors ; antigen-antibody interaction ; immune complex ; molecularly imprinted polymers (MIPs) ; surface modification by immobilization of biomoleculesElectrochemical biosensorDetection theorylcsh:TJ1-1570Electrical and Electronic EngineeringSurface plasmon resonance030304 developmental biologysurface modification by immobilization of biomolecule0303 health sciencesMechanical EngineeringbioelectrochemistryCOVID-19surface modification by immobilization of biomoleculesRNA analysis021001 nanoscience & nanotechnologybiosensorsAntigen-antibody interactionControl and Systems Engineeringmolecularly imprinted polymers (MIPs)antigen-antibody interaction0210 nano-technologyBiological systemBiosensorMicromachines
researchProduct

Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.

2007

The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…

AnalyteCorrelation coefficientAnalytical chemistryFresh WaterAlkaliesAnalytical Chemistrylaw.inventionlawOxidizing agentWater Pollution ChemicalHumansPhotodegradationChemiluminescenceBenzofuransDetection limitReproducibilityChromatographyPhotolysisMolecular StructureChemistryHerbicidesVolumetric flow rateFlow Injection AnalysisLuminescent MeasurementsMineral WatersSulfonic AcidsAcidsTalanta
researchProduct

Development of a Rapid Method for the Determination of Phenolic Antioxidants in Dark Chocolate Using Ultra Performance Liquid Chromatography Coupled …

2017

Development of a new comprehensive method based on one-step liquid-liquid extraction (LLE) combined with ultra-high-performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) for the determination of eight phenolic compounds in dark chocolate is demonstrated. The study focuses on the optimization of sample preparation, chromatographic separation and Orbitrap-HRMS detection parameters to adjust selectivity and sensitivity of the method. The LLE mixture of formic acid-water-acetonitrile (2:58:40, v/v) and hexane at the component ratio of 1:1 (v/v) was applied for sample preparation. The inter-day and intra-day precision expressed from the relative stand…

AnalyteDark chocolateOrbitrapMass spectrometry01 natural sciencesAntioxidantsMass SpectrometryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundfoodPhenolsLimit of DetectionlawLiquid–liquid extractionSample preparationChocolateChromatography High Pressure LiquidChromatography010405 organic chemistryChemistry010401 analytical chemistryExtraction (chemistry)General Medicinefood.food0104 chemical sciencesHexaneJournal of Chromatographic Science
researchProduct

Rapid determination of pharmaceuticals in wastewater by direct infusion HRMS using target and suspect screening analysis

2021

Abstract A wide-scope screening of active pharmaceutical ingredients (APIs) and their transformation products (TPs) in wastewater can yield valuable insights and pinpoint emerging contaminants that have not been previously reported. Such information is relevant to investigate their occurrence and fate in various environmental compartments. In this study, we explored the applicability of direct infusion high resolution mass spectrometry (DI-HRMS) for comprehensive and rapid detection of APIs and their TPs in wastewater samples. The method was developed using a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) system and incorporated both wide-scope suspect screening and…

AnalyteEnvironmental EngineeringChromatography010504 meteorology & atmospheric sciencesWastewater010501 environmental sciencesQuechers01 natural sciencesPollutionRapid detectionFourier transform ion cyclotron resonanceScreening analysisPharmaceutical PreparationsWastewaterNorth AmericaEnvironmental ChemistryEnvironmental scienceSewage treatmentWaste Management and DisposalEffluentWater Pollutants ChemicalChromatography Liquid0105 earth and related environmental sciencesScience of The Total Environment
researchProduct

Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…

2019

Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…

AnalyteEnvironmental EngineeringMaterials scienceFood SafetyHalogenationHealth Toxicology and Mutagenesis0208 environmental biotechnologyAtmospheric-pressure chemical ionization02 engineering and technology010501 environmental sciences01 natural sciencesFourier transform ion cyclotron resonanceGas Chromatography-Mass SpectrometryMass SpectrometryCalibrationHalogenated Diphenyl EthersEnvironmental ChemistryHumans0105 earth and related environmental sciencesFlame RetardantsDetection limitChromatographyFourier AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityCyclotronsPollution020801 environmental engineeringFoodFood productsGas chromatographyFood AnalysisChemosphere
researchProduct

Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

2017

A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…

AnalyteIon-mobility spectrometry02 engineering and technologyMass spectrometry01 natural sciencesBiochemistryAnalytical ChemistryMatrix (chemical analysis)Cocaine-Related DisordersCocaineHumansSolid phase extractionSalivaDetection limitChromatographyChemistryElutionSpectrum Analysis010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Solid Phase ExtractionGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciences0210 nano-technologyJournal of chromatography. A
researchProduct

Experimental Study of the Oriented Immobilization of Antibodies on Photonic Sensing Structures by Using Protein A as an Intermediate Layer

2018

[EN] A proper antibody immobilization on a biosensor is a crucial step in order to obtain a high sensitivity to be able to detect low target analyte concentrations. In this paper, we present an experimental study of the immobilization process of antibodies as bioreceptors on a photonic ring resonator sensor. A protein A intermediate layer was created on the sensor surface in order to obtain an oriented immobilization of the antibodies, which enhances the interaction with the target antigens to be detected. The anti-bovine serum albumin (antiBSA)-bovine serum albumin (BSA) pair was used as a model for our study. An opto-fluidic setup was developed in order to flow the different reagents and,…

AnalyteMaterials scienceIntegrated photonicsSerum albuminBiosensing TechniquesRing resonator02 engineering and technologylcsh:Chemical technologyBiotecnologia01 natural sciencesBiochemistryAntibodiesArticleAnalytical Chemistry010309 opticsResonatorring resonatorsensorQUIMICA ANALITICATEORIA DE LA SEÑAL Y COMUNICACIONES0103 physical scienceslcsh:TP1-1185Electrical and Electronic EngineeringStaphylococcal Protein AInstrumentationIntegrated photonics; ring resonator; sensor; biosensingSensorDetection limitPhotonsChromatographybiologyBiosensingbusiness.industrySerum Albumin BovineRepeatabilityÒptica021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Opticsbiology.proteinbiosensingPhotonics0210 nano-technologybusinessProtein ABiosensorSensors
researchProduct

Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor

2012

We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…

AnalyteMaterials sciencegas detection; optical sensor; Bragg grating; cyclodextrin; aromatic hydrocarbonsTransducersaromatic hydrocarbonsAnalytical chemistryPhysics::OpticsNaphthaleneslcsh:Chemical technologyBiochemistryNoise (electronics)gas detectionArticleAnalytical ChemistryFiber Bragg gratinglcsh:TP1-1185Electrical and Electronic Engineeringoptical sensorInstrumentationDetection limitCyclodextrinsEquipment DesignAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryWavelengthTransducercyclodextrinSolventsBragg gratingGasesRefractometryRefractive indexSensors
researchProduct

Plasmonic Nanosensor Array for Multiplexed DNA-based Pathogen Detection

2019

In this research we introduce a plasmonic nanoparticle based optical biosensor for monitoring of molecular binding events. The sensor utilizes spotted gold nanoparticle arrays as sensing platform. The nanoparticle spots are functionalized with capture DNA sequences complementary to the analyte (target) DNA. Upon incubation with the target sequence, it will bind on the respectively complementary functionalized particle spot. This binding changes the local refractive index, which is detected spectroscopically as the resulting changes of the localized surface plasmon resonance (LSPR) peak wavelength. In order to increase the signal, a small gold nanoparticle label is introduced. The binding ca…

AnalyteMaterials scienceta221Molecular bindingMetal NanoparticlesNanoparticleBioengineering02 engineering and technologybiosensorit01 natural sciencesSensor arrayLimit of DetectionNanosensorplasmonic arrayNanotechnologyLSPR sensingSurface plasmon resonanceDNA FungalInstrumentationPlasmonCandidaDNA detectionFluid Flow and Transfer ProcessesPlasmonic nanoparticlesBase Sequenceta114business.industryProcess Chemistry and Technology010401 analytical chemistryta1182Fourier-transform-imaging spectroscopynanobiotekniikkaDNASurface Plasmon Resonance021001 nanoscience & nanotechnologyplasmonic nanoparticles0104 chemical sciencesAspergillusOptoelectronicsnanohiukkasetGoldDNA Probes0210 nano-technologybusinessACS Sensors
researchProduct