Search results for "detector"

showing 10 items of 3491 documents

The decay of 133mXe.

2007

The decay of (133m)Xe has been re-measured using an electron-transporter spectrometer and a planar HPGe detector. The sample of (133m)Xe was produced by means of proton-induced fission using an ion-guide based on-line mass separator. The deduced K and L+M+... shell conversion coefficients, alpha(Kappa)=6.5(9) and alpha(L+M+...)=2.9(4), agree within the uncertainty limits with the theoretical values and remove the inconsistencies between the previous experimental studies of (133m)Xe.

RadiationSpectrometer010308 nuclear & particles physicsChemistryFissionAnalytical chemistrychemistry.chemical_element01 natural sciencesXenon0103 physical sciencesConversion coefficientsAtomic physicsNuclear Experiment010306 general physicsHpge detectorApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

A combined 148Gd/244Cm source for energy calibration of α-spectrometers

2005

For high-resolution alpha-particle spectroscopy, detector calibration sources of highest performance are required concerning thickness and homogeneity. In addition, the alpha-emitting radionuclides must have adequate half-lives and alpha-emission energies. This paper describes a new type of alpha-emitting calibration source, represented by a mixture of 148Gd and 244Cm. This system covers an alpha-energy range from 3.18 MeV (148Gd) to 5.76 and 5.80 MeV (244Cm). The source has been prepared by electrolytic deposition and has good performance in terms of thickness and homogeneity.

RadiationSpectrometerChemistryHomogeneity (physics)Detector calibrationAnalytical chemistrySpectroscopyApplied Radiation and Isotopes
researchProduct

Diagnostics of capillary mercury–argon high-frequency electrodeless discharge using line shapes

2005

Abstract The profiles of the 253.7 nm spectral line, emitted from the capillary argon–mercury isotope high-frequency electrodeless discharge, are measured by means of a pressure-scanned Fabry–Perot spectrometer. Spectral line profiles are collected from two lamps at the argon pressure of 2 and 10 Torr, in dependence on the discharge current and Hg vapor densities corresponding to the cold spot temperatures of 25–80 °C. By means of a multi-parameter non-linear line profile fitting procedure of multiple overlapping self-reversed Voigt profiles, the temperature of the radiating atoms and the optical density were estimated. The capillary and spherical discharge conditions were compared. The opt…

RadiationZeeman effectMaterials scienceArgonCold spotSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryInstrument functionCapillary actionchemistry.chemical_elementAtomic and Molecular Physics and OpticsSpectral lineMercury (element)symbols.namesakeOpticschemistrysymbolsAtomic physicsbusinessSpectroscopyJournal of Quantitative Spectroscopy and Radiative Transfer
researchProduct

The Miniball spectrometer

2013

The Miniball germanium detector array has been operational at the REX (Radioactive ion beam EXperiment) post accelerator at the Isotope Separator On-Line facility ISOLDE at CERN since 2001. During the last decade, a series of successful Coulomb excitation and transfer reaction studies have been performed with this array, utilizing the unique and high-quality radioactive ion beams which are available at ISOLDE. In this article, an overview is given of the technical details of the full Miniball setup, including a description of the γ-ray and particle detectors, beam monitoring devices and methods to deal with beam contamination. The specific timing properties of the REX-ISOLDE facility are hi…

Radioactive ion beamsNuclear and High Energy PhysicsIon beamREX-ISOLDEONLINECoulomb excitation[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesNuclear physicsSETUPCOULOMB-EXCITATION0103 physical sciencesNuclear fusionSILICON STRIP DETECTOR[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]RELATIVISTIC ENERGIES010306 general physicsNuclear ExperimentNEUTRON KNOCKOUTPhysicsNuclear Physics; Heavy Ions; Hadrons; Particle and Nuclear Physics; Nuclear FusionLarge Hadron ColliderSpectrometerNUCLEI010308 nuclear & particles physicsDetectorRADIOACTIVE ION-BEAMSemiconductor detectorPhysics::Accelerator PhysicsGE DETECTORS
researchProduct

The SPEDE spectrometer

2017

8 pags., 10 figs., 2 tabs.

Radioactive ion beamsNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsElectron spectrometerPhysics::Instrumentation and DetectorsFOS: Physical sciencesElectronnucl-ex7. Clean energy01 natural sciencesMomentumNuclear physicsInternal conversion0103 physical sciencesNuclear Physics - ExperimentDetectors and Experimental TechniquesNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear Experimentphysics.ins-detPhysicsLarge Hadron ColliderSpectrometer010308 nuclear & particles physicsInstrumentation and Detectors (physics.ins-det)Magnetic fieldPhysics::Accelerator Physics
researchProduct

A new off-line ion source facility at IGISOL

2019

An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap mass measurements, laser spectroscopy and atom trap experiments.

Radioactive ion beamsNuclear and High Energy PhysicsTechnologyPhysics - Instrumentation and DetectorsMaterials sciencetutkimuslaitteetFOS: Physical sciencesSeparator (oil production)Physics Atomic Molecular & Chemical01 natural sciencesIonNuclear physicsPhysics::Plasma Physics0103 physical sciencesAtomPhysics::Atomic PhysicsIGISOLNuclear Experiment (nucl-ex)Nuclear Experiment010306 general physicsSpectroscopyNuclear Science & TechnologyDischarge ion sourceNuclear ExperimentInstrumentationInstruments & InstrumentationScience & TechnologyIsotope010308 nuclear & particles physicsPhysicsInstrumentation and Detectors (physics.ins-det)Ion sourcePhysics NuclearPhysical SciencesPhysics::Accelerator PhysicsydinfysiikkaOff lineSurface ion source
researchProduct

Towards commissioning the new IGISOL-4 facility

2013

Abstract The Ion Guide Isotope Separator On-Line facility at the Accelerator Laboratory of the University of Jyvaskyla is currently being re-commissioned as IGISOL-4 in a new experimental hall. Access to intense beams of protons and deuterons from a new MCC30/15 cyclotron, with continued possibility to deliver heavy-ion beams from the K = 130 MeV cyclotron, offers extensive opportunities for long periods of fundamental experimental research, developments and applications. A new layout of beam lines with a considerable increase in floor space offers new modes of operation at the facility, as well as a possibility to incorporate more complex detector setups. We present a general overview of I…

Radioactive ion beamsNuclear and High Energy Physicsta114Project commissioningComputer scienceNuclear engineeringDetectorCyclotronExperimental researchlaw.inventionNuclear physicslawNeutronInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Twin GEM-TPC prototype (HGB4) beam test at GSI and Jyväskylä : a development for the Super-FRS at FAIR

2017

The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy bra…

Radioactive ion beamsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsSeparator (oil production)hiukkaskiihdyttimet01 natural sciences7. Clean energy114 Physical sciencesParticle identificationNuclear physics0103 physical sciencesElectronicsNuclear ExperimentdetectorsPhysicsta114010308 nuclear & particles physicsProjectileI.2.7Detectorparticle acceleratorsilmaisimetAntiprotonPhysics::Accelerator PhysicsF.2.2Beam (structure)
researchProduct

The SPEDE Spectrometer: Combined In-Beam γ-ray and Conversion Electron Spectroscopy with Radioactive Ion Beams

2015

The SPEDE spectrometer [1] aims to combine a silicon detector, for the detection of electrons, with the MINIBALL γ-ray detection array for in-beam studies employing radioactive ion beams at the HIE-ISOLDE facility at CERN. The setup will be primarily used for octupole collectivity [2] and shape coexistence studies [3, 4] in Coulomb excitation experiments. In the shape coexistence cases the transitions between states of the same spin and parity have enhanced E0 strength [5]. Additionally the 0→0 transitions, typically present in nuclei exhibiting shape coexistence [6], can only occur via E0 transitions, i.e. via internal conversion electron emission.

Radioactive ion beamsPhysicsLarge Hadron ColliderSpectrometerta114Physics::Instrumentation and DetectorsParity (physics)Coulomb excitationElectronElectron spectroscopyPhysics::Accelerator PhysicsSilicon detectorAtomic physicsconversion electron spectrometersNuclear Experiment
researchProduct

Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition

2015

CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.

Radiology Nuclear Medicine and ImagingMaterials scienceContactschemistry.chemical_elementElectroless depositionCrystalsMetalNickelOhmic contactAnodesInstrumentationNuclear and High Energy Physicbusiness.industryBlocking (radio)MethanolMetallurgyDetectorSettore FIS/01 - Fisica SperimentaleDetectorsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeLow noiseNickelchemistryvisual_artvisual_art.visual_art_mediumOptoelectronicsGoldbusiness
researchProduct