Search results for "device"
showing 10 items of 1286 documents
A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study
1999
In this study we examined a new thrombectomy catheter device. Different kinds of in vitro generated thrombi and cadaver thrombi were disrupted in test tubes. The mean disruption rate (and disruption time for 1 g of thrombus) was 225 +/- 65 mg/sec (5 +/- 2 sec) for whole-blood, 117 +/- 60 mg/sec (12 +/- 9 sec) for fibrin, 41 +/- 18 mg/sec (30 +/- 18 sec) for mixed, 70 +/- 42 mg/sec (17 +/- 5 sec) for unorganized, 45 +/- 8 mg/sec (22 +/- 4 sec) for partly, and 5 +/- 1 mg/sec (216 +/- 29 sec) for completely organized cadaver thrombi (P0.05). More than 99% of fragmented particles of whole-blood thrombi were 0-12 microm in diameter. The particle size of fibrin, mixed, and cadaver thrombi was sim…
Infectious complications associated with short-term mechanical circulatory support in urgent heart transplant candidates
2021
[Abstract] Introduction and objectives. Short-term mechanical circulatory support is frequently used as a bridge to heart transplant in Spain. The epidemiology and prognostic impact of infectious complications in these patients are unknown. Methods. Systematic description of the epidemiology of infectious complications and analysis of their prognostic impact in a multicenter, retrospective registry of patients treated with short-term mechanical devices as a bridge to urgent heart transplant from 2010 to 2015 in 16 Spanish hospitals. Results. We studied 249 patients, of which 87 (34.9%) had a total of 102 infections. The most frequent site was the respiratory tract (n = 47; 46.1%). Microbiol…
What Is the Impact of Innovative Electronic Health Interventions in Improving Treatment Adherence in Asthma? The Pediatric Perspective
2019
Suboptimal adherence to treatment is a significant issue in the management of pediatric asthma and is a major cause of uncontrolled disease, life-threatening attacks, and increased utilization of healthcare resources. Electronic health (e-Health) solutions have the potential to positively impact asthma self-management in children and adolescents and their families, thereby improving treatment adherence and asthma outcomes. However, there is a lack of sufficient data to support widespread adoption of e-Health tools in pediatric asthma practice. A critical evaluation of the impact of these new interventions on treatment adherence in childhood asthma must consider unmet needs, heterogeneity of…
Chambered warm moist air eyelid warming devices – a review
2021
Background Eyelid warming is an important treatment for meibomian gland dysfunction (MGD). Specialized chambered devices, using warm moist air have been developed. Purpose To critically evaluate the literature on the safety and efficacy of chambered warm moist air devices in MGD treatment and pinpoint areas of future research. Methods PubMed and Embase were searched on 06 June 2021. The search term was ‘(warm OR heat OR steam OR goggle OR spectacle OR moist air) AND (meibomian OR MGD OR blepharitis OR eyelid OR dry eye OR DED)’. All relevant articles with available English full text were included. Results Eighteen articles assessing the application of chambered warm moist air eyelid warming…
Impella CP in cardiogenic shock due to acute myocardial infarction: From primary angioplasty to LIMA-LAD grafting.
2021
The EDUCA (Elderly and Device Use in Chronic Asthma) multicentre Italian study on the assessment of errors and satisfaction in using the inhalers in …
2017
Background: The incorrect use of inhalers can negatively affect the outcomes of asthma treatment. We assessed whether, and to what extent, this is the case in elderly asthmatics. Methods: This is an observational, multicentre Italian study enrolling mild-to-severe asthmatic patients aged ≥65 yrs treated with inhaled drugs, by DPI or pressurized MDI (pMDI). Critical errors, patient9s satisfaction with their inhaler and adherence were evaluated by means of validated questionnaires; the patients were also trained to a correct use of their device. After 3 to 6 months patient were revaluated. Results: To date, 312 patients have been included (41% males, median age 71 yrs). At least one critical …
THERAPEUTIC AND COLATERAL EFFECTS OF 25-HYDRXYCHOLECAICI FEROL IN VITAMIN D DEFICIENCY
1974
Vitamin D polar metabolite, 25–HCC has been used in 2 infant groups whose ages range from 0–18 months. In the 1st group of 15 infants, all of them suffered from rickets, clinically, biochemistry and radiologically and no prophylactic vitamin D administration could be demonstrated. The control group (15 infants too) was admitted with similar diseases but no one suffered from rickets. Routine determinations for metabolic assesment of Ca phosphoric metabolism were perforaed in plasma and in 240. urine collections, prior and after 25–HCC adBinietration. The rickets group received 20 mcg/day, orally for 20 days and the control 10mcg/day in the same way. The biochemical study demonstrated that bo…
Pulsed radiofrequency energy device (PEAK plasmablade™) and CustomBone® Cranioplasty: an appealing surgical rendez-vous
2019
Background: CustomBone® prosthesis is a widely recognized effective and successful technique for the reconstruction of cranial bone defects. Prior the cranioplasty implant, meticulous dissection wi...
Physical Activity, Sedentary Behavior, and Time in Bed Among Finnish Adults Measured 24/7 by Triaxial Accelerometry
2021
Background: Studies measuring physical activity (PA) and sedentary behavior on a 24/7 basis are scarce. The present study assessed the feasibility of using an accelerometer at the hip while awake and at the wrist while sleeping to describe 24/7 patterns of physical behavior in working-aged adults by age, sex, and fitness. Methods: The study was based on the FinFit 2017 study where the physical behavior of 20- to 69-year-old Finns was assessed 24/7 by triaxial accelerometer (UKKRM42; UKK Terveyspalvelut Oy, Tampere, Finland). During waking hours, the accelerometer was kept at the right hip and, during time in bed, at the nondominant wrist. PA variables were based on 1-min exponential moving …
Comparison of Standard Cardiopulmonary Resuscitation Versus the Combination of Active Compression-Decompression Cardiopulmonary Resuscitation and an …
2003
Background— Active compression-decompression (ACD) CPR combined with an inspiratory impedance threshold device (ITD) improves vital organ blood flow during cardiac arrest. This study compared survival rates with ACD+ITD CPR versus standard manual CPR (S-CPR). Methods and Results— A prospective, controlled trial was performed in Mainz, Germany, in which a 2-tiered emergency response included early defibrillation. Patients with out-of-hospital arrest of presumed cardiac pathogenesis were sequentially randomized to ACD+ITD CPR or S-CPR by the advanced life support team after intubation. Rescuers learned which method of CPR to use at the start of each work shift. The primary end point was 1-ho…