Search results for "diagnostics."
showing 10 items of 190 documents
Characteristic Kα emission of electron cyclotron resonance ion source plasmas
2018
This thesis presents the results of an investigation of the volumetric Kα emission rate/inner shell ionization rate from an Electron Cyclotron Resonance Ion Source (ECRIS) plasma tuned predominantly for high charge state ion production. The experimental work include four complimentary studies covering the influence of a parametric sweep of the four source tune parameters i.e microwave power, neutral gas flow, biased disc voltage and magnetic field on the volumetric Kα emission rate, an investigation into the gas mixing effect, an investigation into the effectiveness of double-frequency heating mode and finally an investigation into microwave induced electron losses (relative and direct) from th…
A novel approach to β-decay: PANDORA, a new experimental setup for future in-plasma measurements
2022
International audience; Theoretical predictions as well as experiments performed at storage rings have shown that the lifetimes of β-radionuclides can change significantly as a function of the ionization state. In this paper we describe an innovative approach, based on the use of a compact plasma trap to emulate selected stellar-like conditions. It has been proposed within the PANDORA project (Plasmas for Astrophysics, Nuclear Decay Observation and Radiation for Archaeometry) with the aim to measure, for the first time in plasma, nuclear β-decay rates of radionuclides involved in nuclear-astrophysics processes. To achieve this task, a compact magnetic plasma trap has been designed…
The relationship between visible light emission and species fraction of the hydrogen ion beams extracted from 2.45 GHz microwave discharge.
2015
The relationship between Balmer-α and Fulcher-band emissions with extracted H + , H + 2 , and H + 3 ions is demonstrated for a 2.45 GHz microwave discharge. Ion mass spectra and optical measurements of Balmer-α and Fulcher-band emissions have been obtained with a Wien Filter having an optical viewport on the plasma chamber axis. The beam of approximately 1 mA is analyzed for different plasma conditions simultaneously with the measurement of light emissions both with temporal resolution. The use of visible light emissions as a valuable diagnostic tool for monitoring the species fraction of the extracted beams is proposed. peerReviewed
High-affinity and selective detection of pyrophosphate in water by a resorcinarene salt receptor
2017
N-Alkyl ammonium resorcinarenes selectively bind pyrophosphate in pure water with an exceptionally high binding constant of up to 1.60 × 107 M–1, three orders of magnitude higher than ATP.
Kuormituskoe modernin kuvantamisen aikakaudella
2019
Kuormituskoetta käytetään sepelvaltimotaudin ja muidenkin sydänsairauksien diagnosoinnissa, ennusteen arvioinnissa, hoidon suunnittelussa ja seurannassa. Kuormituskokeen keskeisin etu on sen helppo saatavuus sekä avoterveydenhuollossa että erikoissairaanhoidossa. Rasitukseen liittyvien oireiden tai suorituskyvyn heikkenemisen yhteydessä kuormituskoe on edelleen arvokas perustutkimus. Sen käytön keskeisin rajoite liittyy sen diagnostiseen osuvuuteen, ja sepelvaltimotaudin ali- ja ylidiagnostiikan välttämiseksi kuormituskokeen käyttö tulisikin rajata liikuntakykyisiin potilaisiin, joilla taudin todennäköisyys ennen testiä on keskisuuri tai suuri. Kuormituskoe sopii potilaille, joiden lepo-EKG…
Weighted local second-order statistics for complex spatio-temporal point processes
2019
Spatial, temporal, and spatio-temporal point processes, and in particular Poisson processes, are stochastic processes that are largely used to describe and model the distribution of a wealth of real phenomena. When a model is fitted to a set of random points, observed in a given multidimensional space, diagnostic measures are necessary to assess the goodness-of-fit and to evaluate the ability of that model to describe the random point pattern behaviour. The main problem when dealing with residual analysis for point processes is to find a correct definition of residuals. Diagnostics of goodness-of-fit in the theory of point processes are often considered through the transformation of data in…
The structure of coronal plasma in active stellar coronae from density measurements
2005
We have analyzed high-resolution X-ray spectra of a sample of 22 active stars observed with the High Energy Transmission Grating Spectrometer (HETGS) on Chandra in order to investigate their coronal plasma density, using the lines of the He-like ions O VII, Mg XI, and Si XIII. Si XII lines in all stars of the sample axe compatible with the low-density limit (i.e. n(e) = 10(30) erg/s); O VII lines yield much lower densities of a few 10(10) cm(-3). Our results indicate that the "hot" and "cool" plasma resides in physically different structures. Our findings imply remarkably compact coronal structures, especially for the hotter (similar to 7 MK) plasma emitting the Mg xi lines characterized by…
Mental Skills of an Athlete as a Resource of Professional Longevity in Sport
2021
The aim of the study was to assess associations between dimensions of mental skills, psychological readiness and predictors of career longevity among current athletes. Mental skills dimensions were measured with the Ottawa Mental Skills Assessment Tool (OMSAT). The psychological predictors of athletic career longevity were measured with the Athletic Coping Skills Scale-28 (the ACSI-28) producing scores for seven coping skills and with the Competitive State Anxiety Inventory-2 (CSAI-2) which produced scores for confidence in competition. Overall, 253 current athletes (average age 22 years) of various competitive levels (classified to 5 groups according to the national sport classification sy…