Search results for "distortion"
showing 10 items of 309 documents
On the effectiveness of numerical simulation in the prediction of profile distortion in extrusion
2005
Among the so-called ‘traditional processes’, extrusion represents one of the most diffused and utilized, since it permits the production of many industrial parts and raw materials. Of course, relevant knowledge on process mechanics and practice is nowadays available in the technical literature and in properly constructed handbooks. On the other hand, the introduction of finite element simulation, as a powerful analysis and design tool, opened new perspectives. Nowadays many researchers are involved in research tasks aimed at explaining some peculiar extrusion aspects. In this paper the effectiveness of numerical simulation for a complex three-dimensional extrusion process analysis is inves…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions
2015
Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…
Comparative evaluation of pulse width modulation techniques on effective DC link voltage utilization of grid connected inverter
2016
In this paper, comparison between two different Pulse Width Modulation (PWM) techniques employed for three phase voltage source inverter (VSI) is discussed. The three phase voltage source inverter is basic topology used to supply a grid. In this paper we have design a LC filter between the inverter and the grid in order to stabilize the output voltage. The filter gives sinusoidal three phase voltage at the output of the inverter with almost zero/less harmonic distortion. A suitable PWM technique is employed to obtain the required output voltage in the line side of the inverter. The PWM generation techniques used mainly based on sinusoidal based Pulse Width Modulation (SPWM) and Space Vector…
Guidelines for the design and implementation of the ARPCC control applied to grid-connected converters
2013
Abstract This paper presents implementation details of the adaptive robust predictive current control (ARPCC) applied to a grid-connected converter, such as feed-forward cancellation protocol, the selection of the observer gain and adaptive parameters or the sampling options, needed to get the best performance of this control. The feed-forward term cancellation permits to achieve a very low harmonic distortion in current waveforms when the voltage sensing circuits are well calibrated. A detailed gain adjustment protocol of the voltage sensing circuits is presented in this paper. Moreover, a control design procedure based on the observer gain L o boundaries and the adaptive parameters has be…
The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion
2007
For the electricity metering for billing purposes in distribution systems, the static meters are substituting the traditional inductive meters. Thus, the evaluation of the performances of such equipments is required, also in the presence of disturbances affecting the power systems. With respect to this, this paper analyzes the main aspects related to the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Particular attention is given to the reference standard meters, that are not considered by the actual in-force Standards. The analysis is supported by several experimental tests.
Disturbing Load Detection in Three-Wire and Four-Wire Systems Based on Novel Nonactive Powers From IEEE 1459-2000
2010
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems, both three-wire and four-wire. It is based on the IEEE Std. 1459-2000 effective apparent power resolution, and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In this paper, the formulation of the novel approach is given, and its effectiveness is discussed by means of several simulation tests, which were carried out on a simple test system.
A virtual instrument for the measurement of IEEE Std 1459-2000 power quantities
2006
In this paper, the authors present a PC-based instrument for the measurement of electrical-power quantities defined in IEEE Std. 1459. The instrument is based on a time-domain technique for the detection of the fundamental and harmonic components of voltages and currents. The time-domain strategy was originally developed by the authors for three-phase, three-wire systems. In that paper, the strategy had been extended to both three-phase, four-wire and single-phase systems. Simulation tests were carried out to assess the uncertainty contribution of the proposed strategy in the absence of the measurement transducers. Moreover, the accuracy of the PC-based instrument with its transducers was e…
A New Generalized Robust Predictive Current Control for Grid-Connected Inverters Compensates Anti-Aliasing Filters Delay
2016
In this paper, a new predictive control for grid-connected inverters is presented, which provides the best performance in terms of transient response and stability margins when analog filters in current sensing circuits are used. These filters are necessary to avoid aliasing in the A/D conversion process, which causes an important ripple on injected current into the grid and increases the total harmonic distortion. However, predictive controls are very sensitive to delays on the acquisitions, so when such anti-aliasing filters are used a reduction of stability margins is produced and the transient response is affected. The proposed predictive control allows to compensate the effect of the f…
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.