Search results for "efficient"

showing 10 items of 1603 documents

Simultaneous detection of hazardous skin whitening agents in Indian cosmetic products using a green chromatographic technique

2021

The present work mainly highlights the simultaneous detection of four skin whitening agents i.e. hydroquinone (HQ), resorcinol (RS), catechol (CC) and 3,3′-dichlorobenzidine (DCB) in facial creams and body lotion. Among these, the first three are positional isomers of dihydroxybenzene so simultaneous separation is difficult with the conventional reverse-phase high-performance liquid chromatographic technique (RP-HPLC). The selected skin whitening agents were detected in facial cream and body lotion using micellar liquid chromatography coupled to a photodiode array detector (MLC-PDA). In the present study, optimization of the method was accomplished using response surface methodology (RSM) w…

Detection limitChromatographyQD71-142Correlation coefficientCentral composite designmicellar liquid chromatographycosmeticsResorcinolCosmeticsresponse surface methodologychemistry.chemical_compoundSkin whitening agentsskin whitening agentschemistryPulmonary surfactantResponse surface methodologyMicellar liquid chromatographyLotionResponse surface methodologyAnalytical chemistryMicellar liquid chromatographyJournal of Chromatography Open
researchProduct

A clean method for flow injection spectrophotometric determination of cyclamate in table sweeteners

2005

Abstract A flow system based on the multicommutation is proposed for fast and clean determination of cyclamate. The procedure exploits the reaction of cyclamate with nitrite in acidic medium and the spectrophotometric determination of the excess of nitrite by iodometry. The flow system was designed with a set of solenoid micro-pumps to minimize reagent consumption and waste generation. The detection limit was estimated as 30 μmol L −1 (99.7% confidence level) with linear response ranging up to 3.0 mmol L −1 . The coefficient of variation was estimated as 1.7% for a solution containing 2.0 mmol L −1 cyclamate ( n  = 20). About 60 samples can be analyzed per hour, consuming only 3 mg KI and 1…

Detection limitChromatographymedicine.diagnostic_testChemistryCoefficient of variationBiochemistryAnalytical ChemistryWaste generationchemistry.chemical_compoundIodometrySpectrophotometryReagentmedicineEnvironmental ChemistryNitriteEffluentSpectroscopyAnalytica Chimica Acta
researchProduct

A multicommuted flow system with solenoid micro-pumps for paraquat determination in natural waters.

2007

A flow system designed with solenoid micro-pumps is proposed for the determination of paraquat in natural waters. The procedure involves the reaction of paraquat with dehydroascorbic acid followed by spectrophotometric measurements. The proposed procedure minimizes the main drawbacks related to the standard chromatographic procedure and to flow analysis and manual methods with spectrophotometric detection based on the reaction with sodium dithionite, i.e. high solvent consumption and waste generation and low sampling rate for chromatography and high instability of the reagent in the spectrophotometric procedures. A home-made 10-cm optical-path flow cell was employed for improving sensitivit…

Detection limitFlow injection analysisParaquatChromatographyAutoanalysismedicine.diagnostic_testHerbicidesCoefficient of variationAnalytical chemistryWaterHydrogen-Ion ConcentrationDehydroascorbic AcidAnalytical ChemistrySolventSodium dithionitechemistry.chemical_compoundKineticschemistryParaquatSpectrophotometryReagentSpectrophotometryFlow Injection AnalysismedicineTechnology PharmaceuticalTalanta
researchProduct

Micropumping multicommutation turbidimetric analysis of waters

2007

Abstract A micropumping multicommutation manifold to perform turbidity determinations in waters is described. The procedure is based on the use of a combination of hydrazine sulfate and hexamethylenetetramine, to obtain an external standard of nephelometric turbidity units (NTU), which could compare the absorbance measurements at high wavelengths for samples with a calibration line obtained from a concentrated formazine standard diluted on-line. To minimize sample and reagent consumption and waste generation, the flow system was designed with two solenoid micro-pumps, one of them for the alternative introduction of the formazine standard and samples and the other one for the water carrier. …

Detection limitStandard curveAbsorbancechemistry.chemical_compoundChromatographyChemistryReagentCoefficient of variationAnalytical chemistryTurbidityFormazineAnalytical ChemistryDilutionTalanta
researchProduct

Supercritical fluid extraction of resveratrol from grape skin of Vitis vinifera and determination by HPLC

2000

Supercritical fluid extraction of resveratrol from grape skin of Vitis vinifera was studied. Extraction variables such pressure, modifier concentration (ethanol), and extraction time were optimised. Final extraction conditions were: 40 degrees C, 150 bar, 7.5% ethanol and extraction time 15 min. Extraction recovery and precision (variation coefficient between 0.2 and 1.0%) were calculated. The resveratrol content in the ethanolic extract was determined by HPLC with UV detection at 306 nm. Acetic acid-methanol-water was used as the mobile phase, and C-18 and C-8 columns were tested, instrumental parameters were optimised, and analytical parameters were calculated (lineal interval 0-75 mg l(-…

Detection limitWinechemistry.chemical_compoundChromatographychemistryCoefficient of variationExtraction (chemistry)Supercritical fluid extractionResveratrolHigh-performance liquid chromatographyQuantitative analysis (chemistry)Analytical ChemistryTalanta
researchProduct

Agreement among 3 optical imaging methods for the assessment of optic disc topography.

2005

Purpose To assess the agreement of disc topography measurements between the Heidelberg Retina Tomograph (HRT II), Retinal Thickness Analyzer (RTA), and Optical Coherence Tomograph (StratusOCT). Design Observational cross-sectional study. Participants Forty-two randomly chosen eyes of 42 subjects. Methods Each subject underwent HRT II, RTA, and StratusOCT examination. Two experienced examiners drew the contour lines for the HRT II and RTA. Bland and Altman plots were used to evaluate agreement for each topographic parameter among the instruments. The Spearman coefficient of rank correlation was evaluated for each topographic parameter. Main Outcome Measures Agreement in the measurement of op…

Diagnostic ImagingMaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskGlaucomaSpearman's rank correlation coefficientRetinal thickness analyzerOptical imagingNerve FibersOphthalmologyLinear regressionOptic Nerve DiseasesMedicineHumansIntraocular PressureRank correlationAgedRetrospective Studiesbusiness.industryReproducibility of ResultsMiddle Agedmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureCross-Sectional StudiesFemalesense organsTomographybusinessGlaucoma Open-AngleOptic discOphthalmology
researchProduct

Hidden Markov random field model and Broyden–Fletcher–Goldfarb–Shanno algorithm for brain image segmentation

2018

International audience; Many routine medical examinations produce images of patients suffering from various pathologies. With the huge number of medical images, the manual analysis and interpretation became a tedious task. Thus, automatic image segmentation became essential for diagnosis assistance. Segmentation consists in dividing the image into homogeneous and significant regions. We focus on hidden Markov random fields referred to as HMRF to model the problem of segmentation. This modelisation leads to a classical function minimisation problem. Broyden-Fletcher-Goldfarb-Shanno algorithm referred to as BFGS is one of the most powerful methods to solve unconstrained optimisation problem. …

Dice coefficient criterionComputer scienceBrain image segmentation02 engineering and technologyMR-images[INFO.INFO-AI]Computer Science [cs]/Artificial Intelligence [cs.AI]Theoretical Computer Science03 medical and health sciences0302 clinical medicineArtificial Intelligence0202 electrical engineering electronic engineering information engineering[INFO]Computer Science [cs]SegmentationBrain magnetic resonance imagingHidden Markov modelRandom fieldbusiness.industryBroyden-Fletcher-Goldfarb-Shanno algorithmPattern recognitionImage segmentationhidden Markov random fieldMinimization3. Good healthHomogeneousBroyden–Fletcher–Goldfarb–Shanno algorithm020201 artificial intelligence & image processingAutomatic segmentationArtificial intelligenceHidden Markov random fieldbusiness030217 neurology & neurosurgerySoftwareJournal of Experimental & Theoretical Artificial Intelligence
researchProduct

Atom- and Bond-Based 2D TOMOCOMD-CARDD Approach and Ligand-Based Virtual Screening for the Drug Discovery of New Tyrosinase Inhibitors

2008

Two-dimensional atom- and bond-based TOMOCOMD-CARDD descriptors and linear discriminant analysis (LDA) are used in this report to perform a quantitative structure-activity relationship (QSAR) study of tyrosinase-inhibitory activity. A database of inhibitors of the enzyme is collected for this study, within 246 highly dissimilar molecules presenting antityrosinase activity. In total, 7 discriminant functions are obtained by using the whole set of atom- and bond-based 2D indices. All the LDA-based QSAR models show accuracies above 90% in the training set and values of the Matthews correlation coefficient (C) varying from 0.85 to 0.90. The external validation set shows globally good classifica…

DicumarolQuantitative structure–activity relationshipStereochemistryTyrosinaseQuantitative Structure-Activity RelationshipLigandsBiochemistryAnalytical ChemistrySmall Molecule Librarieschemistry.chemical_compoundDrug DiscoveryCluster AnalysisVirtual screeningDrug discoveryChemistryComputational BiologyDiscriminant AnalysisReproducibility of ResultsMatthews correlation coefficientLigand (biochemistry)Linear discriminant analysisCombinatorial chemistryMolecular MedicinePeptidesKojic acidBiotechnologySLAS Discovery
researchProduct

Über die verdünnungsentropie der lösungen von fadenmolekülen

1953

Es wird versucht, auf breiter experimenteller Basis, einen allgemeinen uberblick uber die Wechselwirkung zwischen Polymeren und Losungsmitteln (LM) in masigen Konzentrationen (bis 3%) zu gewinnen. Zu diesem Zweck wird der osmotische Druck in Abhangigkeit von der Konzentration und der Temperatur fur 2 verschiedene Polymere in einer groseren Anzahl von Losungsmitteln gemessen und daraus die Virialkoeffizienten und die thermodynamischen Funktionen Δμ1, Δh1 und Δs1 berechnet. Der 1. Virialkoeffizient (VK) A hangt, wie zu erwarten war, nur vom Molekularge which des Polymeren ab. Der 2. und der 3. VK werden in der Grose B zusammengefast, die ein Mas fur die „Gute” des LM ist. Die differentielle V…

Differential heatVirial coefficientChemistryPolymer chemistryWeight rangeVolume concentrationDie Makromolekulare Chemie
researchProduct

Epitaxial growth and thermoelectric properties of TiNiSn and Zr0.5Hf0.5NiSn thin films

2011

Abstract Due to their exceptional thermoelectric properties Half-Heusler alloys like MNiSn (M = Ti,Zr,Hf) have moved into focus. The growth of single crystalline thin film TiNiSn and Zr 0.5 Hf 0.5 NiSn by dc magnetron sputtering is reported. Seebeck and resistivity measurements were performed and their dependence on epitaxial quality is shown. Seebeck coefficient, specific resistivity and power factor for Zr 0.5 Hf 0.5 NiSn at room temperature were measured to be 63 μV K − 1 , 14.1 μΩ m and 0.28 mW K − 2  m − 1 , respectively. Multilayers of TiNiSn and Zr 0.5 Hf 0.5 NiSn are promising candidates to increase the thermoelectric figure-of-merit by decreasing thermal conductivity perpendicular …

DiffractionMaterials scienceCondensed matter physicsMetals and AlloysSurfaces and InterfacesSputter depositionEpitaxySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsThermal conductivityElectrical resistivity and conductivitySeebeck coefficientThermoelectric effectMaterials ChemistryThin filmThin Solid Films
researchProduct