Search results for "equipment and supplies"

showing 10 items of 483 documents

Drug eluting and bare metal stents in people with and without diabetes: Collaborative network meta-analysis

2008

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence fr…

medicine.medical_specialtyPaclitaxelmedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Restenosis03 medical and health scienceschemistry.chemical_compound0302 clinical medicineBlood vessel prosthesisInternal medicinemedicineHumans030212 general & internal medicinecardiovascular diseasesGeneral Environmental ScienceRandomized Controlled Trials as TopicSirolimusbusiness.industryResearchHazard ratioGeneral EngineeringDrug-Eluting StentsGeneral Medicineequipment and supplies3. Good healthSurgeryBlood Vessel ProsthesisProsthesis FailureClinical trialsurgical procedures operativePaclitaxelchemistryDrug-eluting stentMeta-analysisSirolimusGeneral Earth and Planetary SciencesPlatelet aggregation inhibitorStentsbusinessDiabetic AngiopathiesPlatelet Aggregation Inhibitorsmedicine.drug
researchProduct

Iatrogenic pulmonary lesions.

2018

Treatment of patients often includes the administration of medications and sometimes radiation. While the intent is to treat an underlying condition, in some cases, adverse effects occur due to these agents. Most of these adverse effects are mild, however, some can be severe and life-threatening. Furthermore, while these effects are often reversible upon cessation of exposure, especially if the inciting agent is recognized and withdrawn early, others might be permanent or even progressing. Most common histopathologic findings in drug-induced interstitial lung disease include nonspecific interstitial pneumonia (cellular and/or fibrotic), organizing pneumonia with or without bronchiolitis, eo…

medicine.medical_specialtyPathologyDrug-Related Side Effects and Adverse ReactionsPolymersIatrogenic DiseaseAmiodaroneAntineoplastic Agents030204 cardiovascular system & hematologyPathology and Forensic Medicine03 medical and health sciences0302 clinical medicineEarly Medical InterventionmedicineEosinophilic pneumoniaHumansImmunologic FactorsIntensive care medicineDiffuse alveolar damageAdverse effectLungLungRadiotherapybusiness.industryInterstitial lung diseasePulmonary edemamedicine.diseasemedicine.anatomical_structureEquipment and SuppliesNitrofurantoin030220 oncology & carcinogenesisPulmonary hemorrhagebusinessLung Diseases InterstitialAnti-Arrhythmia AgentsHydrophobic and Hydrophilic InteractionsHypersensitivity pneumonitisSeminars in diagnostic pathology
researchProduct

Inter-relationship between platelet-derived microparticles and oxidative stress in patients with venous thromboembolism

2020

Background: Hypercoagulative conditions play a key role in venous thromboembolism (VTE). Inflammation is currently linked to VTE, but the potential role of circulating microparticles and oxidative stress (OxS) must be elucidated. The aim of this study was to evaluate platelet-derived microparticles and surrogate OxS biomarkers in patients diagnosed with VTE through a case&ndash

medicine.medical_specialtyPhysiologyThiobarbituric acidvenous thromboembolismClinical Biochemistry030204 cardiovascular system & hematologymedicine.disease_causeBiochemistryGastroenterologyPathophysiologyArticleSuperoxide dismutase03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePlatelet degranulationInternal medicinemedicineTBARSoxidative stressPlateletcardiovascular diseases030212 general & internal medicineMolecular BiologymicroparticlesVenous thromboembolism.biologybusiness.industrylcsh:RM1-950PlateletbiomarkersCell BiologyBiomarkerequipment and suppliesMalondialdehydelcsh:Therapeutics. PharmacologyClotting timechemistryMicroparticleplateletsbiology.proteinOxidative strebusinessOxidative stress
researchProduct

Substantial Reduction of Platelet Adhesion by Heparin-Coated Stents

2001

Although optimized antiplatelet medication has improved the clinical outcome after coronary stenting, vessel occlusion and restenosis still remain a relevant clinical problem. Platelets play a key role in this process. Therefore, the authors compared the platelet adhesion on different stent surface modifications (electropolished without coating or coated with carbon, carbon and additional heparin, silicon carbide, or heparin alone) to investigate their role in reducing platelet adhesion. All stents and additional stainless steel plates were incubated in heparinized whole blood with radiolabeled platelets. After washing the stents and plates four times, radioactivity caused by the adhesion o…

medicine.medical_specialtyPlatelet adhesionmedicine.medical_treatmentIn Vitro Techniquesengineering.materialPlatelet AdhesivenessRestenosisCoatingmedicineHumansRadiology Nuclear Medicine and imagingPlateletWhole bloodHeparinbusiness.industryGraft Occlusion VascularAnticoagulantsStentHeparinAdhesionequipment and suppliesmedicine.diseaseSurgeryengineeringStentsCardiology and Cardiovascular MedicinebusinessBiomedical engineeringmedicine.drugJournal of Interventional Cardiology
researchProduct

Proximale Verankerung von Hüft-Endoprothesen mit poröser Oberfläche: 6-Jahres-Ergebnisse

2008

PROBLEM The anatomically shaped pcl (ESKA) total hip replacement has a porous coating of the proximal stem and the cup to allow for bony ingrowth. The tip of the stem is polished. METHOD We report the results of 96 THR 6.2 years (5.25-6.7) after implantation. RESULTS There were no revisions during this period. One stem showed radiographic loosening at follow-up. There was stress-shielding in 9.4% in contrast to the concept of proximal fixation. Thigh-pain was found in 9.4%. One patient demonstrated disabling thigh-pain despite radiologic bony ingrowth. By drilling the femur distal to the tip of the stem a remarkable relief was achieved. CONCLUSION Despite numerous cases of stress-shielding …

medicine.medical_specialtyPorous coatingChirurgie orthopediquebusiness.industryRadiographyTotal hip replacementequipment and suppliesSurgeryOrthopedic surgeryThigh painMedicineOrthopedics and Sports MedicineSurgeryFemurbusinessNuclear medicineFixation (histology)Zeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Value of serial magnetic resonance imaging in the assessment of brain metastases volume control during stereotactic radiosurgery

2016

AIM To evaluate brain metastases volume control capabilities of stereotactic radiosurgery (SRS) through serial magnetic resonance (MR) imaging follow-up. METHODS MR examinations of 54 brain metastases in 31 patients before and after SRS were reviewed. Patients were included in this study if they had a pre-treatment MR examination and serial follow-up MR examinations at 6 wk, 9 wk, 12 wk, and 12 mo after SRS. The metastasis volume change was categorized at each follow-up as increased (> 20% of the initial volume), stable (± 20% of the initial volume) or decreased (< 20% of the initial volume). RESULTS A local tumor control with a significant (P < 0.05) volume decrease was observed in 25 meta…

medicine.medical_specialtyPseudo progressionBrain metastasemedicine.medical_treatmentPseudo-progressionVolume controlRadiosurgery03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineRetrospective StudymedicineStereotactic radiosurgerymedicine.diagnostic_testbusiness.industryBrain metastasesMagnetic resonance imagingequipment and suppliesRadiation therapyRadiation therapySerial magnetic resonance imaging030220 oncology & carcinogenesisRadiologyNuclear medicinebusinesshuman activities030217 neurology & neurosurgeryWorld Journal of Radiology
researchProduct

Identifying physical activity type in manual wheelchair users with spinal cord injury by means of accelerometers

2015

Objectives: The main objective of this study was to develop and test classification algorithms based on machine learning using accelerometers to identify the activity type performed by manual wheelchair users with spinal cord injury (SCI). Setting: The study was conducted in the Physical Therapy department and the Physical Education and Sports department of the University of Valencia. Methods: A total of 20 volunteers were asked to perform 10 physical activities, lying down, body transfers, moving items, mopping, working on a computer, watching TV, arm-ergometer exercises, passive propulsion, slow propulsion and fast propulsion, while fitted with four accelerometers placed on both wrists, c…

medicine.medical_specialtySupport Vector MachinePARTICIPATIONPhysical activityComputerApplications_COMPUTERSINOTHERSYSTEMSACTIVITY RECOGNITIONMotor ActivityAccelerometerFunctional LateralityManual wheelchairTECNOLOGIA ELECTRONICAPhysical medicine and rehabilitationPEOPLEAccelerometryMedicineHumansVALIDITYSpinal cord injurySpinal Cord InjuriesAgedbusiness.industryVALUESENERGY-EXPENDITUREDiscriminant AnalysisReproducibility of ResultsPARAPLEGIAGeneral MedicineWristACTIVITY MONITORequipment and suppliesmedicine.diseasenervous system diseasesActivity monitorCross-Sectional StudiesNeurologyEnergy expenditureWheelchairsComputerSystemsOrganization_MISCELLANEOUSPhysical therapyComputingMilieux_COMPUTERSANDSOCIETYNeurology (clinical)InformationSystems_MISCELLANEOUSbusinessParaplegiahuman activities
researchProduct

Retrograde recanalization of an in-stent ostial chronically occluded right coronary artery

2010

We describe a case of a chronic proximal in-stent CTO extending up to the ostium of a right coronary artery where successful achievement of guidewire passage through the CTO was performed with a retrograde approach. Guidewire trapping into the right guiding catheter was performed thereafter and procedure was completed by retrograde balloon crossing and antegrade stenting. © 2009 Elsevier Ireland Ltd.

medicine.medical_specialtySurgical approachbusiness.industrymedicine.medical_treatmentStentPCIequipment and suppliesBalloonRetrograde approach.SurgeryCTOOstiumsurgical procedures operativeRight coronary arterymedicine.arteryConventional PCIRetrograde approachGuiding catheterMedicinecardiovascular diseasesRadiologyCardiology and Cardiovascular MedicinebusinessInternational Journal of Cardiology
researchProduct

Translational development and pre-clinical evaluation of prototype gastrointestinal mock-up devices: only robotic placement of plastic?

2020

Background: The aim of this study was to address the vision of wireless theranostic devices distributed along the gastrointestinal (GI) tract by defining design requirements, developing prototype mock-ups, and establishing a minimally invasive surgical approach for the implantation process. Methods: Questionnaires for contextual analysis and use case scenarios addressing the technical issues of an implantable GI device, a possible scenario for implantation, preparation and calibration of a device, and therapeutic usage by professionals and patients were completed and discussed by an interdisciplinary team of surgeons, engineers, and product designers. Two acute porcine experiments were cond…

medicine.medical_specialtySwineComputer scienceeducation0206 medical engineeringBiomedical Engineering02 engineering and technology01 natural sciencesTranslational Research BiomedicalRobotic Surgical ProceduresmedicineAnimalsMinimally Invasive Surgical ProceduresMedical physics010401 analytical chemistryRobotic Surgical ProceduresEquipment DesignProstheses and ImplantsGeneral Medicineequipment and supplies020601 biomedical engineering0104 chemical sciencesGastrointestinal TractPrinting Three-DimensionalPlasticsClinical evaluationJournal of Medical Engineering &amp; Technology
researchProduct

Der Sicherheitsgurt: Auswirkungen auf das Verletzungsmuster von Autoinsassen

1993

Since 1984 the law concerning safety belts has been implemented; this paper deals with the findings in 386 victims of motor accidents who were x-rayed between 1981 and 1989. Minor injuries have been ignored. The number of passengers wearing belts increased by 30% after 1984. The number of passenger injuries did not decrease. Injuries directly caused by the belts included a small number of fractures of clavicles, the sternum and ribs and one pelvic fracture, one serious abdominal injury with tearing of the mesenteric artery and one ruptured spleen. An indirect result of wearing seat belts was a marked increase in cervical whiplash injuries and some increase in thoracic vertebral fractures. N…

medicine.medical_specialtybusiness.industryPoison controlequipment and suppliesmedicine.diseasePolytraumalaw.inventionSurgerymedicine.anatomical_structurelawInjury preventionmedicineWhiplashPelvic fractureSeat beltAbdomenRadiology Nuclear Medicine and imagingbusinesshuman activitiesPelvisRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct