Search results for "fields"
showing 10 items of 575 documents
1 Hz repetitive transcranial magnetic stimulation of the unaffected hemisphere ameliorates contralesional visuospatial neglect in humans
2002
The aim of the study was to investigate whether low-frequency repetitive transcranial magnetic stimulation (rTMS) over the unaffected hemisphere can ameliorate visuospatial neglect. We treated three right brain damaged patients with left neglect. 900 pulses (1 Hz frequency) were given over left posterior parietal cortex every other day for 2 weeks. Patients performed a computerized task requiring length judgement of prebisected lines, tachistoscopically presented for 150 ms. With respect to rTMS the task was given 15 days before, at the beginning, at the end and 15 days after. At these times patients performed also line bisection and clock drawing tasks. rTMS induced a significant improveme…
Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry
2012
PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…
Predictive value of heidelberg retina tomograph parameters for the development of glaucoma in the European glaucoma prevention study
2015
Purpose To determine whether baseline Heidelberg Retina Tomograph (HRT) measurements of the optic disc are associated with the development of open-angle glaucoma (OAG) in individuals with ocular hypertension in the European Glaucoma Prevention Study (EGPS). Design Retrospective analysis of a prospective, randomized, multicenter, double-masked, controlled clinical trial. Methods There were 489 participants in the HRT Ancillary Study to the EGPS. Each baseline HRT parameter was assessed in univariate and multivariate proportional hazards models to determine its association with the development of OAG. Proportional hazards models were used to identify HRT variables that predicted which partici…
Prediction Accuracy of a Novel Dynamic Structure-Function Model for Glaucoma Progression
2014
Purpose To assess the prediction accuracy of a novel dynamic structure-function (DSF) model to monitor glaucoma progression. Methods Longitudinal data of paired rim area (RA) and mean sensitivity (MS) from 220 eyes with ocular hypertension or primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Rim area and MS were expressed as percent of mean normal based on an independent dataset of 91 healthy eyes. The DSF model uses centroids as estimates of the current state of the disease and velocity vectors as estimates of direction and rate of change over time. The first three visits were used to pre…
A case study of Primary Progressive Aphasia: improvement on verbs after rTMS treatment.
2006
This case-report shows that high frequency repetitive Transcranial Magnetic Stimulation (hf-rTMS), applied to the left prefrontal cortex, may improve the linguistic skills in Primary Progressive Aphasia (PPA). The patient's performance was evaluated on a battery of language production and memory span tasks, before and after two hf-rTMS treatments and one SHAM treatment. We observed a significant and lasting improvement of the patient's performance on verb production following the application of hf-rTMS versus Baseline and SHAM conditions. This finding suggests that hf-rTMS may directly strengthen the neural connections within an area of metabolic dysfunction and encourages the use of rTMS a…
Tocilizumab as first treatment option in optic neuropathy secondary to Graves' orbitopathy.
2018
Dysthyroid optic neuropathy (DON) is one of the complications that can affect Graves' orbitopathy (GO) patients. Its prevalence is estimated at less than 5%. It is usually treated with intravenous steroids, radiotherapy or orbital decompression. Tocilizumab has been proposed as a treatment option in cases of GO refractory to steroid treatment, with good clinical results. Our aim is to report the case of a patient with optic neuropathy secondary to GO treated with tocilizumab as primary treatment option.
Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes
2015
Color perimetry has interesting clinical application for the diagnosis and detection of certain eye conditions, due to the variations that certain diseases can cause in chromatic thresholds, both in the red-green (RG) and the blue-yellow (BY) pathways.[1,2,3,4] The separate study of the visual function of both the chromatic and achromatic mechanisms could be more efficient in detecting sensitivity variations, and such variations would not be obscured by the intrusion of other mechanisms. Currently, the supply of conventional perimeters that are capable of performing a chromatic perimetry test is very limited and with reduced options regarding the possibility of choosing the physical charact…
V1 non-linear properties emerge from local-to-global non-linear ICA
2006
It has been argued that the aim of non-linearities in different visual and auditory mechanisms may be to remove the relations between the coefficients of the signal after global linear ICA-like stages. Specifically, in Schwartz and Simoncelli (2001), it was shown that masking effects are reproduced by fitting the parameters of a particular non-linearity in order to remove the dependencies between the energy of wavelet coefficients. In this work, we present a different result that supports the same efficient encoding hypothesis. However, this result is more general because, instead of assuming any specific functional form for the non-linearity, we show that by using an unconstrained approach…
Iris-Like Tunable Aperture Employing Liquid-Crystal Elastomers
2014
A liquid-crystal elastomer (LCE) iris inspired by the human eye is demonstrated. With integrated polyimide-based platinum heaters, the LCE material is thermally actuated. The radial contraction direction, similar to a mammalian iris, is imprinted to the LCE by a custom-designed magnetic field. Actuation of the device is reproducible over multiple cycles and controllable at intermediate contraction states.
A Columnar Liquid Crystal with Permanent Polar Order
2015
et al.