Search results for "focal"

showing 10 items of 803 documents

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

2016

Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…

Optics and PhotonicsProsthesis Design01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesDioptreVision OcularMathematicsLenses Intraocularbusiness.industryMultifocal intraocular lensSensory SystemsOptical qualityOphthalmologySpainMetric (mathematics)030221 ophthalmology & optometrySurgeryObjective evaluationSpatial frequencybusinessFocus (optics)Journal of cataract and refractive surgery
researchProduct

Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Focal Length Measuring Technique Using The Talbot Effect

1987

The Talbot effect - or self-imaging phenomenon - is applied to the measurement of focal lengths. The technique only requires axial distances to be measured and is suitable for both converging and diverging thick lenses.

OpticsDistance measurementElectromagnetismbusiness.industryTalbot effectFocal lengthImage acquisitionImage processingSpatial frequencybusinessCollimated lightMathematicsSPIE Proceedings
researchProduct

THREE-DIMENSIONAL INTEGRAL MICROSCOPY WITH ENHANCED RESOLUTION AND DEPTH OF FIELD

2016

In this contribution we explain two new techniques developed by our group, which permit to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy.

OpticsMaterials sciencebusiness.industryMultifocal plane microscopyLight sheet fluorescence microscopyResolution (electron density)MicroscopyScanning confocal electron microscopyDigital holographic microscopyDepth of fieldbusinessImage resolutionImaging and Applied Optics 2016
researchProduct

Differentiative pathway activated by 3-aminobenzamide in human osteosarcoma MG-63 cells involves FAK and PAK activities.

2006

PARP inhibitorosteosarcomafocal adhesions
researchProduct

Behavior of Human Osteoblast Cells Cultured on Titanium Discs in Relation to Surface Roughness and Presence of Melatonin

2017

The aim of this work was to observe the behavior of osteoblast cells cultured in vitro on titanium discs in relation to disc surface roughness and the addition of melatonin to the culture medium. MG63 osteoblast cells were cultivated on 120 Grade 5 Ti divided into three groups: Group E, treated with dual acid etch; Group EP, treated with dual acid etch and calcium phosphate; and Group M, machined. Surface roughness was examined under a laser scanning confocal microscope (CLSM) and scanning electron microscopy (SEM). The proliferation and morphology of cells were determined under fluorescence microscopy and SEM. Messenger ribonucleic acid (mRNA) of different genes related to osteoblastic dif…

PHEXSurface PropertiesproliferationmRNAConfocalchemistry.chemical_elementmelatoninosteoblasts; titanium; roughness; melatonin; proliferation; differentiation; mRNA; PHEX; dental implantsCalciumArticleCatalysisOsseointegrationCell LineInorganic ChemistryMelatonin03 medical and health sciences0302 clinical medicinedental implantsCell AdhesionmedicineFluorescence microscopeHumansRNA MessengerPhysical and Theoretical ChemistryMolecular BiologySpectroscopyCell ProliferationroughnessTitaniumMicroscopy ConfocalOsteoblastsCell growthOrganic ChemistryCell DifferentiationOsteoblastdifferentiation030206 dentistryGeneral MedicineAnatomyMolecular biologyIn vitroComputer Science Applicationsmedicine.anatomical_structurechemistryMicroscopy Electron Scanning030217 neurology & neurosurgerymedicine.drugInternational Journal of Molecular Sciences
researchProduct

Impact on flavour release of the structure of composite gels containing polysaccharides: Example of the fruit préparations

2006

The main objective of this study was to understand the respective rôle of the structure of a food product and of the physicochemical interactions on flavour release. For that purpose, fruit préparations hâve been chosen as model matrices. Those matrices contain a polysaccharide as gelling agent, a cross-linked waxy corn starch (1.4%), a high sucrose content (35%), an acidic buffer and a strawberry aroma (17 molécules). Four matrices were developed by modifying either the composition or the concentration in gelling agent: two matrices of similar texture containing either LM pectin or carrageenan, and two carrageenan based matrices with différent gelled structures. In a first step; two comple…

PURGE AND TRAPFLAVOUR RELEASECONFOCAL LASER SCANNING MICROSCOPY[SPI.GPROC] Engineering Sciences [physics]/Chemical and Process EngineeringCOEFFICIENTS DE PARTAGEAPCI-MSPARTITION COEFFICIENTSFRUIT PREPARATIONS[SDV.IDA] Life Sciences [q-bio]/Food engineeringDIFFUSIONNMR-PFG-DOSYRMN-PFG-DOSYMICROSCOPIE CONFOCALERHEOLOGYGELS COMPOSITESRHEOLOGIECINETIQUES DE LIBERATION DES COMPOSES D'AROMECOMPOSITE GELSBASES DE FRUITS-SUR-SUCRE
researchProduct

Role of Recycling Endosomes and Lysosomes in Dynein-Dependent Entry of Canine Parvovirus

2002

ABSTRACT Canine parvovirus (CPV) is a nonenveloped virus with a 5-kb single-stranded DNA genome. Lysosomotropic agents and low temperature are known to prevent CPV infection, indicating that the virus enters its host cells by endocytosis and requires an acidic intracellular compartment for penetration into the cytoplasm. After escape from the endocytotic vesicles, CPV is transported to the nucleus for replication. In the present study the intracellular entry pathway of the canine parvovirus in NLFK (Nordisk Laboratory feline kidney) cells was studied. After clustering in clathrin-coated pits and being taken up in coated vesicles, CPV colocalized with coendocytosed transferrin in endosomes r…

Parvovirus CanineEndosomeanimal diseasesvirusesImmunologyDyneinCoated vesicleEndosomesBiologyEndocytosisMicrobiologyMicrotubulesCell LineDogsMicrotubuleVirologyAnimalsMicroscopy ImmunoelectronIn Situ Hybridization FluorescenceMicroscopy ConfocalVesicleEndoplasmic reticulumDyneinsEndocytosisCell biologyVirus-Cell InteractionsCytoplasmInsect ScienceLysosomes
researchProduct

Assembly of fluorescent chimeric virus-like particles of canine parvovirus in insect cells

2004

Canine parvovirus (CPV) is a small non-enveloped ssDNA virus composed of the viral proteins VP1, VP2, and VP3 with a T=1 icosahedral symmetry. VP2 is nested in VP1 and the two proteins are produced by differential splicing of a primary transcript of the right ORF of the viral genome. The VP2 protein can be further proteolytically cleaved to form VP3. Previous studies have shown that VP1 and VP3 are unnecessary for capsid formation and consequently, that VP2 alone is sufficient for assembly. We have hypothesized that insertion of the enhanced green fluorescent protein (EGFP) at the N-terminus of VP2 could be carried out without altering assembly. To investigate the possibility to develop flu…

Parvovirus CanineRecombinant Fusion ProteinsvirusesGreen Fluorescent ProteinsBiophysicsHeterologousFluorescence correlation spectroscopySpodopteraBiochemistryVirusCell LineInclusion Bodies ViralGreen fluorescent proteinAnimalsAmino Acid SequenceMolecular BiologyMicroscopy ConfocalBase SequencebiologyChimeraVirus AssemblyCanine parvovirusvirus diseasesCell Biologybiochemical phenomena metabolism and nutritionbiology.organism_classificationMolecular biologyFusion proteinLuminescent ProteinsMicroscopy ElectronCapsidRNA splicingCapsid ProteinsPlasmidsBiochemical and Biophysical Research Communications
researchProduct