Search results for "gamma ray"
showing 10 items of 397 documents
Neutron and gamma-ray radiation fields characterisation in a 241Am–Be irradiator in view of its use as research testing tool
2020
Abstract A neutron irradiation facility based on four 241Am–Be sources, each one with an activity of 111 GBq, placed in Plexiglas pipes inside a tank filled with water used both as a moderator and a biological shielding, has been realized at the Engineering Department of Palermo University. In view of its use as a testing tool in various research activities, a characterisation of the irradiator has been carried out through the determination of neutron and gamma-ray flux profiles, the evaluation of the thermal to total neutron flux percentage ratio and of the epithermal neutron shaping factor. To this aim, results of a Monte Carlo (MCNP5 code) simulation based on a previously validated sourc…
Estimation of external gamma radiation dose in the area of Bory Stobrawskie forests (PL).
2011
The study assessed the radiological risks associated with the presence of natural and artificial radionuclides in the Bory Stobrawskie forests (PL). Using the conversion factors given by UNSCEAR and the measurements results of (232)Th series, (238)U series, (40)K, and (137)Cs specific activities in the 10-cm soil layer the values of absorbed dose (D) and the annual effective dose equivalent derived from terrestrial gamma radiation (E) were calculated. The calculated dose was compared with doses directly measured on the area studied.
Evidence for a critical dose above which damage to carbonate ester bonds in PADC appear after gamma ray and ultra soft X-ray exposures
2020
Abstract It has been confirmed that the density of carbonate ester in poly(allyl diglycol carbonate) (PADC), which is a well-known polymeric nuclear track detector CR-39, begins decreasing above a critical dose of about 60 kGy during exposures to Co-60 gamma rays and Ultra Soft X-rays (USX: Kα (Al) with energy 1.49 keV). After exposure to Co-60 gamma rays at 77 K and room temperature (RT), a significant difference in Electron Spin Resonance (ESR) spectra has been observed at both sides of a critical dose of 60 kGy, where is a threshold for the degradation of carbonate ester in PADC. Namely, the types of free radicals in PADC are different from each other below and above this critical dose. …
Impact of prompt gamma emission of 44Sc on quantification in preclinical and clinical PET systems
2021
Abstract 44Sc is an increasingly investigated positron emitter for use in positron emission tomography (PET) imaging. However, 44Sc is a non-pure positron emitter, since prompt photons are co-emitted during the decay process. This study investigates coincidence energy spectra of 44Sc and its impact on PET quantification on a preclinical and clinical PET system in comparison with 18F. The raw data of the coincidence events revealed characteristic differences comparing the photon energy distribution of 44Sc and 18F. Due to prompt gamma emission of 44Sc, activity recovery is underestimated on PET systems. However, clinical PET imaging of 44Sc with acceptable quantitative accuracy appears feasi…
Determination of the irradiation field at the research reactor TRIGA Mainz for BNCT.
2009
For the application of the BNCT for the excorporal treatment of organs at the TRIGA Mainz, the basic characteristics of the radiation field in the thermal column as beam geometry, neutron and gamma ray energies, angular distributions, neutron flux, as well as absorbed gamma and neutron doses must be determined in a reproducible way. To determine the mixed irradiation field thermoluminescence detectors (TLD) made of CaF(2):Tm with a newly developed energy-compensation filter system and LiF:Mg,Ti materials with different (6)Li concentrations and different thicknesses as well as thin gold foils were used.
The contribution of the Italian Northern Cross Radiotelescope to the Gamma-Ray Observatory Pulsar Timing Network
1992
The observation of pulsars at gamma-ray energy requires updated pulsar parameters in order to fold the gamma-ray data over time intervals of weeks. The Compton Gamma-Ray Observatory Institute has set up an international agreement including several radiotelescopes and pulsar observers in order to provide a suitable timing support at radio wavelengths. In this paper we describe the system used at the Italian Northern Cross for the pulse timing observations related to the GRO mission.
Digital CZT detector system for high flux energy-resolved X-ray imaging
2017
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…
Ge-doping dependence of gamma-ray induced germanium lone pair centers in Ge-doped silica
2008
We report an experimental study on the y irradiation effects in Ge-doped sol-gel silica samples doped with Ge from 10 2 up to 10 4 part per million molar. The samples were exposed to the radiation generated by a 60 Co source up to an accumulated dose value of 10 MGy. Our data evidence that the γ irradiation significantly increases the number of Germanium Lone Pair Centers (GLPC). Such defects are induced with a concentration that depends on the Ge content of the employed material in those samples where no optical activity related to -s GLPC was detected before irradiation. Furthermore an increase of the GLPC concentration was detected also in a sample that already contains this defect after…
TASISpec—A highly efficient multi-coincidence spectrometer for nuclear structure investigations of the heaviest nuclei
2010
TASISpec (TASCA in Small Image mode Spectroscopy) combines composite Ge- and Si-detectors for a new detector setup aimed towards multi-coincidence gamma -ray, X-ray, conversion electron, fission fragment, and a-particle spectroscopy of the heaviest nuclei. It exploits the TASCA separator's unique small image focal mode, i.e. the fact that evaporation residues produced in fusion-evaporation reactions can be focused into an area of less than 3 cm in diameter. This provides the possibility to pack detectors in very close geometry, resulting in an unprecedented detection efficiency of radioactive decays in prompt and delayed coincidence with implanted nuclei. Crown Copyright (C) 2010 Publis…
Recent trends in the development of CdTe and CdZnTe semiconductor detectors for astrophysical applications
2010
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) offer great promise as x-ray and gamma ray detectors. Due to the high detection efficiency, the good room temperature performance and the recent improvements on crystal growth technology, CdTe and CdZnTe detectors have obtained an increasing interest in the field of hard x-ray and gamma ray astronomy. In this paper, we report on the R&D activities on CdTe and CdZnTe detectors for high energy space instrumentation. Our group has been involved in the design of new multilayer hard x and soft gamma ray Laue lens telescopes and, in particular on the development of focal plane detectors based on CdTe and CdZnTe. Here we present the acti…