Search results for "harmonic distortion"

showing 10 items of 67 documents

Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …

2010

In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…

power measurement harmonic distortion power definitions IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems

2009

This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEE…

Settore ING-INF/07 - Misure Elettriche E Elettronichepower measurements harmonic distortion reactive power power quality IEEE Std 1459
researchProduct

Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoid…

2009

In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.

Total harmonic distortionEngineeringbusiness.industryControl engineeringCharacterization (materials science)MetrologyIdentification (information)Electric power systemHarmonicsElectrical and Electronic EngineeringbusinessInstrumentationAccuracy classSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltageEnergy measurements harmonic distortion power quality power systems static meters
researchProduct

Experimental Investigation on the Performances of a Multilevel Inverter Using a Field Programmable Gate Array-Based Control System

2019

The Field Programmable Gate Array (FPGA) represents a valid solution for the design of control systems for inverters adopted in many industry applications, because of both its high flexibility of use and its high-performance with respect to other types of digital controllers. In this context, this paper presents an experimental investigation on the harmonic content of the voltages produced by a three-phase, five level cascaded H-Bridge Multilevel inverter with an FPGA-based control board, aiming also to evaluate the performance of the FPGA through the implementation of the main common modulation techniques and the comparison between simulation and experimental results. The control algorithm…

Control and Optimizationmultilevel convertersrenewable energiesComputer scienceEnergy Engineering and Power TechnologyMultilevel converterContext (language use)Renewable energieSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricilcsh:TechnologyVHDLElectronic engineeringElectrical and Electronic EngineeringField-programmable gate arrayEngineering (miscellaneous)FPGAcomputer.programming_languageTotal harmonic distortionRenewable Energy Sustainability and the Environmentlcsh:TSettore ING-IND/31 - ElettrotecnicaControl systemHarmonicInvertercomputerPulse-width modulationEnergy (miscellaneous)VoltageEnergies
researchProduct

IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment

2018

The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.

harmonic sources; IEEE Std. 1459-2010; power definitions; power measurement; power quality020209 energy02 engineering and technologyAC powerAutomotive engineeringlaw.inventionPower (physics)harmonic distortionHarmonic analysisCapacitorHarmonic pollutionlawPower ratio0202 electrical engineering electronic engineering information engineeringHarmonicPoint of common couplingPower measurement harmonic distortion power definitions power quality IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E ElettronicheMathematics2018 18th International Conference on Harmonics and Quality of Power (ICHQP)
researchProduct

Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers

2007

This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.

Total harmonic distortionEngineeringbusiness.industryPower system harmonicsPower quality harmonic distortion reactive power power system harmonics detection of harmonic sources.AC powerPower (physics)Electric power systemTransducerHarmonic pollutionElectronic engineeringMetering modebusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems

2019

With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…

010302 applied physicsTotal harmonic distortionbusiness.industryComputer scienceripple020209 energyElectrical engineering02 engineering and technologyDC streConvertersmultilevel converter01 natural sciencesHarmonic analysisSynchronization (alternating current)partial dischargeSettore ING-IND/31 - ElettrotecnicaharmonicHarmonics0103 physical sciences0202 electrical engineering electronic engineering information engineeringHarmonicPDWaveformVoltage sourcebusiness2019 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)
researchProduct

An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems

2009

This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.

Total harmonic distortionEngineeringbusiness.industryharmonic distortion power definitions power quality harmonic sourcesAC powerHarmonic analysisElectric power systemPower system simulationThree-phaseElectronic engineeringHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Dead-time impact on the harmonic distortion and conversion efficiency in a three-phase five-level Cascaded H-Bridge inverter: mathematical formulatio…

2023

To avoid leg short-circuit in inverters, dead time must be introduced on leg gate signals. Dead time affects the inverter output voltage fundamental harmonic amplitude, voltage harmonic distortion and inverter efficiency by introducing additional voltage drops. In this regard, dead time effects have been widely investigated for traditional two-level three-phase voltage source inverters in the literature but not extensively for multilevel topology structures. This paper provides a detailed analysis of dead time impact on the harmonic distortion and efficiency of Cascaded H-Bridges Multilevel Inverters (CHBMIs). For this purpose, a general mathematical formulation to determine voltage drop du…

General Computer ScienceDead Time Efficiency Harmonic analysis Harmonic Distortion Inverters Modulation Multi Carrier PWM Multilevel Inverter Power harmonic filters Pulse width modulation Switching frequency VoltageGeneral EngineeringGeneral Materials ScienceElectrical and Electronic EngineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici
researchProduct

A New Software Tool for Design, Optimization, and Complete Analysis of Rotating Electrical Machines Windings

2015

In this paper, a new software tool developed by the authors for ac winding design, optimization, and complete analysis is presented. In particular, this software can be used as a valid aid in design and analysis for a wide variety of motor and generator windings with generic number of phases (including the case of those machines in which some slots are left empty), pole pairs, slot number, and so on. The calculation of winding factors and the evaluation of their harmonic distribution is also accomplished. The software is implemented in the MATLAB programming environment. By means of some examples, covering the most relevant winding types, the capabilities of this software will be shown. In …

Differential leakageTotal harmonic distortionElectromotive forceComputer scienceFluxSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciTopologyElectronic Optical and Magnetic MaterialswindingHarmonic analysisharmonicMagnetomotive forceElectromagnetic coilmagnetomotive force (MMF)Harmonicsflux densityWinding factorwinding factorsElectrical and Electronic Engineeringwinding connectionLeakage (electronics)IEEE Transactions on Magnetics
researchProduct