A virtual instrument for the measurement of IEEE Std 1459-2000 power quantities
2006
In this paper, the authors present a PC-based instrument for the measurement of electrical-power quantities defined in IEEE Std. 1459. The instrument is based on a time-domain technique for the detection of the fundamental and harmonic components of voltages and currents. The time-domain strategy was originally developed by the authors for three-phase, three-wire systems. In that paper, the strategy had been extended to both three-phase, four-wire and single-phase systems. Simulation tests were carried out to assess the uncertainty contribution of the proposed strategy in the absence of the measurement transducers. Moreover, the accuracy of the PC-based instrument with its transducers was e…
A New Generalized Robust Predictive Current Control for Grid-Connected Inverters Compensates Anti-Aliasing Filters Delay
2016
In this paper, a new predictive control for grid-connected inverters is presented, which provides the best performance in terms of transient response and stability margins when analog filters in current sensing circuits are used. These filters are necessary to avoid aliasing in the A/D conversion process, which causes an important ripple on injected current into the grid and increases the total harmonic distortion. However, predictive controls are very sensitive to delays on the acquisitions, so when such anti-aliasing filters are used a reduction of stability margins is produced and the transient response is affected. The proposed predictive control allows to compensate the effect of the f…
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…
A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000
2010
In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…
A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
2012
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …
Wind Electrical energy generating systems EMC. A dedicated experimental simulator for tests
2008
In wind electrical energy generating systems, due to fast voltage and current fluctuations, the power converter represents a source of electromagnetic disturbances. EMI problems of stand alone wind generators are here analysed in order to take into account many different power quality problems which result in voltage fluctuations and harmonics in the net. This paper, moreover, presents a wind turbine experimental simulator (WTES) that moves a wind electrical energy generating system (WEEGS) to carry out EMI measurements and the relative experimental results. The WEEGS here taken into account comprises a wound rotor induction generator (WRIG) in which the frequency transformation from the ro…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Harmonic mitigation of a grid-connected photovoltaic system using shunt active filter
2017
Conventional LC filters cannot compensate effectively harmonics due to non-linear loads in a grid-connected photovoltaic (PV) system. Thus, active power filters (APF) are introduced due to its characteristics and performances, for compensation of harmonics from non-linear loads in the grid-connected photovoltaic (PV) system. This work presents a three-phase voltage-fed shunt active power filter implementation to mitigate the harmonics in which the filter control system focuses on generating reference source current for compensating harmonic effects from non-linear loads. Furthermore, the developed model is verified with an experimental data from a nonlinear load.
A PC-based instrument for harmonics and interharmonics measurement in power supply systems
2004
Abstract Growing interest on power quality has led international working groups to define new standards for testing and measurement techniques to apply to power systems. Special attention has been paid to harmonic and interharmonic measurements. Here, the authors introduce a PC-based instrument capable of synchronising sampling frequency with fundamental frequency in order to perform on-line voltage or current distortion analysis. The instrument has been developed in accordance with currently available standards and international documents, IEC 61000-4-7 Ed. 2002, IEC 61000-4-30 Ed. 2003, Draft Guide IEEE P1159.1 Ed. 2003 and limits given by IEC 61000 Part. 3. A detailed description of the …