Search results for "image processing"
showing 10 items of 3285 documents
Early emergence of deviant frontal fMRI activity for phonological processes in poor beginning readers.
2010
Phonological awareness refers to the ability to perceive and manipulate the sound structure of language and is especially important when children learn to read. Poor phonological awareness is considered the major cause for the emergence of reading difficulties. In this functional magnetic resonance imaging (fMRI) study, we examined the brain correlates of phonological processing in young beginning readers (aged 8.3+/-0.4 y, 2nd grade) with poor (25th percentile) or normal, age-appropriate reading skills (40th percentile) using a covert reading and mental letter substitution task. Letter substitution in words and nonwords induced pronounced activity in a left frontal language network related…
Spatial calibration of structured illumination fluorescence microscopy using capillary tissue phantoms.
2008
Quantitative assessment of microvascular structure is relevant to the investigations of ischemic injury, reparative angiogenesis and tumor revascularization. In light microscopy applications, thick tissue specimens are necessary to characterize microvascular networks; however, thick tissue leads to image distortions due to out-of-focus light. Structured illumination confocal microscopy is an optical sectioning technique that improves contrast and resolution by using a grid pattern to identify the plane-of-focus within the specimen. Because structured illumination can be applied to wide-field (nonscanning) microscopes, the microcirculation can be studied by sequential intravital and confocal…
Coronary CT angiography using iterative reconstruction vs. filtered back projection: evaluation of image quality.
2014
To compare image quality of iterative reconstruction algorithm(IRIS) vs. standard filtered back projection(FBP) reconstruction in CT Coronary Angiography (CTCA).Thirty-four consecutive patients underwent CTCA for suspected or known CAD with Dual-Source CT (DSCT-Flash, Siemens). All datasets were reconstructed with 0.75/0.4 and 0.6/0.4 mm slice thickness/increment, using three standard FBP kernels (B26-B30-B46) and three comparable IRIS algorithms (I26-I30-I46). Vascular attenuation and noise were measured. CT vascular attenuation values [HU] were measured in: ascending aorta (Ao), right (RCA) and left (LCA) coronary artery, respectively. Signal-to-noise (SNR) and contrast-to-noise (CNR) rat…
CASA-Mot technology: how results are affected by the frame rate and counting chamber.
2017
For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10 µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20 µm . The frame rate was previously limited by the hardware, although chang…
Harmonized benchmark labels of the hippocampus on magnetic resonance: The EADC-ADNI project
2015
Abstract Background A globally harmonized protocol (HarP) for manual hippocampal segmentation based on magnetic resonance has been recently developed by a task force from European Alzheimer's Disease Consortium (EADC) and Alzheimer's Disease Neuroimaging Initiative (ADNI). Our aim was to produce benchmark labels based on the HarP for manual segmentation. Methods Five experts of manual hippocampal segmentation underwent specific training on the HarP and segmented 40 right and left hippocampi from 10 ADNI subjects on both 1.5 T and 3 T scans. An independent expert visually checked segmentations for compliance with the HarP. Descriptive measures of agreement between tracers were intraclass cor…
Non-granule PSA-NCAM immunoreactive neurons in the rat hippocampus
2002
The polysialylated form of the neural cell adhesion molecule (PSA-NCAM) continues to be expressed in the adult hippocampus, mainly in a subset of neurons located in the innermost portion of the granule cell layer. PSA-NCAM immunoreactive neurons have also been described outside this layer in humans, where they are severely reduced in schizophrenic brains. Given this important clinical implication, we were interested in finding whether similar neurons existed in the adult rat hippocampus and to characterize their distribution, morphology and phenotype. PSA-NCAM immunocytochemistry reveals labeled neurons in the subiculum, fimbria, alveus, hilus, and stratum oriens, lucidum and radiatum of CA…
Texture analysis of cardiac cine magnetic resonance imaging to detect nonviable segments in patients with chronic myocardial infarction.
2017
[EN] Purpose: To investigate the ability of texture analysis to differentiate between infarcted nonviable, viable, and remote segments on cardiac cine magnetic resonance imaging (MRI). Methods: This retrospective study included 50 patients suffering chronic myocardial infarction. The data were randomly split into training (30 patients) and testing (20 patients) sets. The left ventricular myocardium was segmented according to the 17-segment model in both cine and late gadolinium enhancement (LGE) MRI. Infarcted myocardium regions were identified on LGE in short-axis views. Nonviable segments were identified as those showing LGE 50%, and viable segments those showing 0 < LGE < 50% transmural …
Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study
2017
International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean…
High-definition endoscopy with i-Scan and Lugol’s solution for more precise detection of mucosal breaks in patients with reflux symptoms
2009
BACKGROUND AND STUDY AIMS: Patients with gastroesophageal reflux disease are subdivided into non-erosive (NERD) and erosive reflux disease (ERD). The newly available EPKi processor enables high-definition resolution above HDTV standard (HD+). The aim of the study was to test the efficacy of HD+ esophagogastroduodenoscopy alone and in conjunction with i-Scan (newly developed postprocessing digital filter) and chromoendoscopy (Lugol’s solution) for differentiation of reflux patients. METHODS: The distal esophagus of patients with heartburn was inspected with three imaging modalities. HD+ was followed by i-Scan and 15-mL Lugol’s solution (1.5 %). The esophagus was evaluated for mucosal breaks …
Computer assisted sperm morphometry in mammals: a review.
2014
Computer-assisted sperm morphometry analysis (CASMA or ASMA) systems were developed to reduce the subjectivity of sperm morphology assessement. This review focuses on a complete description of the CASMA technique, including recent developments, factors of variation, results in the different species and possible applications. Techniques to study sperm morphometry include light microscopy, phase-contrast microscopy and, more recently, fluorescence microscopy. Most published studies on sperm morphometry have been centered on the whole sperm heads, although some of them also measured other parts of the sperm structure, such as the nucleus, acrosome, midpiece or flagellum. The independent study …