Search results for "implants"
showing 10 items of 505 documents
E-ABR in Patients with Cochlear Implant: A Comparison between Patients with Malformed Cochlea and Normal Cochlea
2019
Objectives This study aims to compare the electrical auditory brainstem response (EABR) following cochlear implant (CI) surgery in pediatric subjects with cochlear malformation and a normal cochlea, in order to assess the sensitivity of EABR and to evaluate the surgery outcome. Materials and methods A total of 26 pediatric subjects who were deaf and scheduled for CI surgery were enrolled into this case control study. Group A (n=20) included subjects with a normo-conformed cochlea. Group B (n=6) included subjects with cochlear malformation. Subjects were evaluated with EABR immediately (T0) and 6 months (T1) post-CI surgery. The EABR Waves III and V average amplitude and latency were compare…
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.
2009
Background: There is a lack of clinical studies on the self-aligning attachment system (Locator®; Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. MaterialsandMethods: From 2003 to 2007, 60 patients received two Osseotite® TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded throug…
Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study
2017
Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact…
"In vivo" evaluation of the vascular pattern in oral peri-implant tissues.
2011
Abstract Introduction The vascularisation of the peri-implant tissue represents the key factor in obtaining a successful result in implantology, since an adequate vascular supply allows wound healing and the presence of numerous growth factors that promote osteogenesis. The aim of this study was to analyse “in vivo” the vascular pattern of the peri-implant mucosa in subjects that received implant treatment. Materials and methods In the study 22 subjects were examined, 11 of whom (test group) received dental implants (Straumann Dental Implant System ® ) while 11 were in the control group; the analysis was performed in the peri-implant masticatory mucosa. The evaluation of the microcirculatio…
Boosting syntax training with temporally regular musical primes in children with cochlear implants
2018
International audience; Objectives : Previous research has suggested the use of rhythmic structures (implemented in musical material) to improve linguistic structure processing (i.e., syntax processing), in particular for populations showing deficits in syntax and temporal processing (e.g., children with developmental language disorders). The present study proposes a long-term training program to improve syntax processing in children with cochlear implants, a population showing syntax processing deficits in perception and production.Methods : The training program consisted of morphosyntactic training exercises (based on speech processing) that were primed by musical regular primes (8 sessio…
Mechanical behavior of provisional implant prosthetic abutments
2014
Introduction: Implant-supported prostheses have to overcome a major difficulty presented by the morphology and esthetics of peri-implant tissues in the anterior sector. Diverse therapeutic techniques are used for managing the mucosa adjacent to the implant and the most noteworthy is immediate/deferred fixed provisionalization. Objectives: In vitro testing of strength and deformation of implant prosthetic abutments made from different materials (Titanium/PEEK/methacrylate). Material and Methods: Forty Sweden&Martina® implant prosthetic abutments (n=40) were divided into five groups: Group MP: methacrylate provisional abutments with machined titanium base; Group PP: Poly ether ether ketone (P…
Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog
2010
Objective: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. Material and methods: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically asse…
Tuning of the Mg Alloy AZ31 Anodizing Process for Biodegradable Implants
2021
Coatings were grown on the AZ31 Mg alloy by a hard anodizing process in the hot glycerol phosphate-containing electrolyte. Anodizing conditions were optimized, maximizing corrosion resistance estimated by impedance measurements carried out in Hank's solution at 37 °C. A post anodizing annealing treatment (350 °C for 24 h) allowed us to further enhance the corrosion resistance of the coatings mainly containing magnesium phosphate according to energy-dispersive X-ray spectroscopy and Raman analyses. Gravimetric measurements revealed a hydrogen evolution rate within the limits acceptable for application of AZ31 in biomedical devices. In vitro tests demonstrated that the coatings are biocompati…