Search results for "imulation"
showing 10 items of 7271 documents
Ovarian stimulation does not influence the uterine immune environment in healthy infertile women.
2019
Abstract Research question There is some controversy regarding the impact of ovarian stimulation on immune cells in women undergoing IVF. The study's aim was to determine whether ovarian stimulation affected immune uterine cells in healthy women undergoing IVF. Design This prospective cohort study included 28 patients undergoing IVF and 47 healthy oocyte donors. Endometrial biopsies were taken in a natural cycle and after ovarian stimulation. All participants had a normal karyotype, pelvic ultrasound and cervical cytology results and thyroid-stimulating hormone concentration, as well as normal glucose and insulin concentrations and inherited and acquired thrombophilia test results. Screenin…
The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing
2018
Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…
Plasma levels of soluble vascular endothelial growth factor receptor-1 may determine the onset of early and late ovarian hyperstimulation syndrome
2006
BACKGROUND Ovarian hyperstimulation syndrome (OHSS) is a life-threatening condition associated with ovarian stimulation. Its pathophysiology is unknown and its treatment continues to be empirical. Early (E)- and late (L)-OHSS occur in women at risk, though not in all cases. Vascular endothelial growth factor (VEGF) is related to increased vascular permeability in OHSS. We analysed the dynamics of the VEGF system in E- and L-OHSS. METHODS A prospective cohort of women undergoing IVF-ICSI treatment were divided into groups. E-OHSS: Nonpregnant patients classified as women not at risk (group 1) (n = 11) and patients at risk who did not (group 2) (n = 18) and did (group 3) (n = 8) develop sever…
Effectiveness of High-Frequency Transcranial Magnetic Stimulation and Physical Exercise in Women With Fibromyalgia: A Randomized Controlled Trial
2020
Abstract Objective Fibromyalgia (FM) is characterized by chronic widespread pain and both physical and emotional alterations, which in turn may affect the individual’s quality of life. Thus, interventions aimed at treating such symptoms, without increasing fatigue, are needed. The aim of this study was to explore the effect of high-frequency transcranial magnetic stimulation (HF-TMS) and physical exercise (PE) on pain, impact of FM, physical conditioning, and emotional status in women with FM. Methods Forty-nine women with FM were randomly allocated to: (1) a PE group (PEG, n = 16), who underwent an 8-week (two 60-minute sessions/wk) low-intensity PE program; (2) a TMS group (TMSG, n = 17) …
Neural correlates of antinociception in borderline personality disorder.
2006
Context A characteristic feature of borderline personality disorder (BPD) is self-injurious behavior in conjunction with stress-induced reduction of pain perception. Reduced pain sensitivity has been experimentally confirmed in patients with BPD, but the neural correlates of antinociceptive mechanisms in BPD are unknown. We predicted that heat stimuli in patients with BPD would activate brain areas concerned with cognitive and emotional evaluation of pain. Objective To assess the psychophysical properties and neural correlates of altered pain processing in patients with BPD. Design Case-control study. Setting A university hospital. Participants Twelve women with BPD and self-injurious behav…
Phase-specific modulation of cortical motor output during movement observation.
2001
The effects of different phases of an observed movement on the modulation of cortical motor output were studied by means of transcranial magnetic stimulation (TMS). A video-clip of a reaching-grasping action was shown and single TMS pulses were delivered during its passive observation, Times of cortical stimulation were related to the phases of the shown movement, locking them to the appearance of specific kinematic landmarks. The amplitude of the motor evoked potentials (MEPs) induced by TMS in the first dorsal interosseus (FDI) muscle was modulated by the amount of the observed finger aperture. The presence of such an effect is consistent with the notion of a mirror neuron system in premo…
Differences in the nature of body image disturbances between female obese individuals with versus without a comorbid binge eating disorder: an explor…
2011
Various components of body image were measured to assess body image disturbances in patients with obesity. To overcome limitations of previous studies, a photo distortion technique and a biological motion distortion device were included to assess static and dynamic aspects of body image. Questionnaires assessed cognitive-affective aspects, bodily attitudes, and eating behavior. Patients with obesity and a binge eating disorder (OBE, n = 15) were compared with patients with obesity only (ONB; n = 15), to determine the nature of any differences in body image disturbances. Both groups had high levels of body image disturbances with cognitive-affective deficits. Binge eating disorder (BED) par…
Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…
2010
Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
Stretch Reflex Responses Following Mechanical Stimulation in Power- and Endurance-Trained Athletes
1994
The basic stretch reflex responses evoked by the mechanical stimuli were investigated among different athletic groups. The tests were performed by a special ankle ergometer, which created dorsiflexion velocities from 25 deg x s-1 to 115 deg x s-1 around the ankle joint. The EMG activity of soleus (SO), gastrocnemius (GA) and tibialis anterior (TA) muscles was recorded with surface electrodes. In all subjects higher angular velocities caused higher stretch reflex responses. The endurance-trained athletes were more sensitive to the used stimuli than the power-trained athletes, because of their shorter latency times (43 +/- 7 ms vs 45 +/- 7 ms, p < 0.001 for the SO muscle and 40 +/- 8 ms vs 43…