Dead-time impact on the harmonic distortion and conversion efficiency in a three-phase five-level Cascaded H-Bridge inverter: mathematical formulatio…
2023
To avoid leg short-circuit in inverters, dead time must be introduced on leg gate signals. Dead time affects the inverter output voltage fundamental harmonic amplitude, voltage harmonic distortion and inverter efficiency by introducing additional voltage drops. In this regard, dead time effects have been widely investigated for traditional two-level three-phase voltage source inverters in the literature but not extensively for multilevel topology structures. This paper provides a detailed analysis of dead time impact on the harmonic distortion and efficiency of Cascaded H-Bridges Multilevel Inverters (CHBMIs). For this purpose, a general mathematical formulation to determine voltage drop du…
Decoupled control scheme of grid-connected split-source inverters
2017
Grid-connected power conversion systems for renewable energy sources must fulfill several requirements, e.g., the high efficiency, the reduced cost and complexity, and, quite often, the boost capabilities that is usually achieved using a front-end dc–dc boost converter before the inversion stage, leading to a two-stage architecture. Meanwhile, single-stage power conversion systems, which perform the boosting operation within the inversion one, offer some potential advantages, in terms of reducing the complexity and the volume of the whole system. Among several proposed options, the split-source inverter (SSI) has been recently proposed by Abdelhakim et al. as an alternative option with some…
Design issues for wind farms grid tied Inverter
2017
In this paper the Authors give indications for the design of a grid tied Voltage Source Inverters (VSI) aimed to optimal use in energy conversion from wind source. In particular, the design of the inverter is more focused on the control system planning, with a particular glance on the grid synchronization problem. After the exposition of general issues concerning renewable energies and associated topics, the case of a grid tied inverter is considered and a methodology of design is sketched starting from the consideration of the DC side and also considering the power device losses, the protection issue against over voltages and over-currents, snubber circuits, heat sinks and, finally the con…
Selective harmonic mitigation with asymmetrical staircase voltage waveform for a three-phase five-level Cascaded H-Bridge Inverter
2020
Selective harmonics elimination or mitigation strategies are used in all applications where it is necessary to rise the efficiency and reliability of the overall system. This paper presents a simple approach to reduce the low order harmonics amplitude of an asymmetrical staircase voltage waveform for a five-level, three-phase Cascaded H-Bridge Inverter without solving non-linear equations. Through this simple approach, polynomial equations to evaluate the control angels in real-time operations have been found. The effectiveness of the harmonic mitigation method has been tested through the simulation analysis in MatLab/PLECS environment.
Performance assessment of a grid-connected mc-Si PV system made up of silicon material from different manufacturing routes
2013
Summarises the performance of an Elkem Solar photovoltaic (PV) system installed in the Sunbelt Region (between 35 North and 35 South) in Hyderabad, India, which has been fully operational since August 2012. The PV system consists of 28 multicrystalline silicon PV modules made from the standard Siemens process and from material produced by a metallurgical route - the Elkem Solar Silicon (ESS™) process. A comparative performance study of the ESS™ modules with respect to standard polysilicon has been carried out under the various climatic and solar radiation conditions at the location. The present study suggests that the ESS™ PV modules have a slightly better performance than standard polysili…
Extending the Power Range of a Solar Inverter
2018
Solar inverters feature a minimum and maximum limit of the maximum power point voltage. Overcoming these limits leads to a disconnection of the power equipment, thus wasting the solar energy. In this paper, a solution to extend the power range of a solar inverter is presented. The proposed solution extends he minimum maximum power point limit of a commercial solar inverter by means of a battery energy storage system, including a DC/DC power converter. The battery energy storage system is connected in series to the photovoltaic module. If the photovoltaic module voltage drops below the minimum maximum power point limit, the battery energy storage system is enabled thus boosting the input vol…
Innovative Computational Approach to Harmonic Mitigation for Seven-level Cascaded H-Bridge Inverters
2020
Low frequency modulation strategies are a good solution to increase the energy conversion efficiency in high power applications. The paper is devoted to presents an innovative way to low order harmonics mitigation for seven-level Cascaded H-Bridge Inverters. In particular, this approach is based on the mitigation of selected harmonics without solve non-linear equations for an extended range of the fundamental amplitude. In fact, in real-Time operation to evaluate the control angles the polynomial equations have been identified. Through circuit simulation analysis in MatLab/PLECS environment, the effectiveness of the harmonic mitigation method has been tested and compared with theoretical re…
Sensorless variable speed single-phase induction motor drive system
2012
It is usual find single-phase induction motor (SPIM) in several house, office, shopping, farm, and industry applications, which are become each time more sophisticated and requiring variable speed drives. Considering the low cost of this machine, the adoption of sensorless speed control is the more reasonable option for SPIM drives. This paper presents a proposal for sensorless variable speed SPIM drive based on direct rotor field orientation techniques. An observer based on two independent linear close-loop control systems provides the estimation of the rotor flux and speed from the measurements of the stator currents and voltages. These estimatives are used by close-loop systems for speed…
Technical and economical comparison between different topologies of PV plant under mismatch effect
2014
This paper presents a technical and economical comparative analysis between two topology of photovoltaic plant. In particular the performances of series-parallel (SP) and total cross tied (TCT), topologies are taken into account, referring to a partially shaded photovoltaic plant. Thanks to a simulation model developed, in the paper the mismatch effects due to three different shading conditions, for SP and TCT topology plant, are quantified. Since the TCT solution, even though increase the energy production, raise the complexity of plants as well as their costs, an evaluation of the individual costs of each component of a SP and TCT plant topology, as PV modules, support structure, inverter…
Novel Computational Method for Harmonic Mitigation for Three-phase Five-level Cascaded H-Bridge Inverter
2018
The efficiency of the system is a very important parameter for high power electrical drives applications,. Moreover, in the system the efficiency of the power converter play a fundamental role and for this reason, the soft switching modulation techniques represent the best choice. This paper presents a novel computational method for harmonic mitigation on the output voltage of a five-level, three-phase Cascaded H-Bridge Inverter without solving non-linear equations. Through this simple approach the Working Areas have been identified in which the harmonics reference have minimum amplitude possible. Moreover, polynomial equations to evaluate the control angels have been found. In this way, th…