Search results for "leak"
showing 10 items of 244 documents
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
Anastomotic leakage after colon cancer resection: does the individual surgeon matter?
2016
Aim Anastomotic leakage is one of the most feared complications after colonic resection. Many risk factors for anastomotic leakage have been reported, but the impact of an individual surgeon as a risk factor has scarcely been reported. The aim of this study was to assess if the individual surgeon is an independent risk factor for anastomotic leakage in colonic cancer surgery. Method This was a retrospective analysis of prospectively collected data from patients who underwent elective resection for colon cancer with anastomosis at a specialized colorectal unit from January 1993 to December 2010. Anastomotic leaks were diagnosed according to standardized criteria. Patient and tumour character…
Laparoscopic ileocecal resection in acute and chronic presentations of Crohn's disease. A single center experience
2017
Introduction The terminal ileum is the most involved tract in Crohn's disease. The obstruction in this location is the most frequent complication. Acute or chronic presentations can occur. Surgery finds a role in the management of chronic strictures and in acute clinical presentations with complications not improving with conservative therapy. Patients and methods We investigate the outcome of patients with obstruction of the ileo-cecal bowel tract laparoscopically managed. It was analyzed the average operative time (OT), the conversion rate and the occurrence of re-operation due to surgical complications. Results 21 patients underwent an ileocecal resection for complicated Crohn's disease …
FA01.02: THE EFFECT OF POSTOPERATIVE COMPLICATIONS AFTER MIE ON LONG-TERM SURVIVAL: A RETROSPECTIVE, MULTI-CENTER COHORT STUDY.
2018
Abstract Background Esophagectomy has a high incidence of postoperative morbidity. Complications lead to a decreased short-term survival, however the influence of those complications on long-term survival is still unclear. Most of the performed studies are small, single center cohort series with inconclusive or conflicting results. Minimally invasive esophagectomy (MIE) has been shown to be associated with a reduced postoperative morbidity. In this study, the influence of complications on long-term survival for patients with esophageal cancer undergoing a MIE were investigated. Methods Data was collected from the EsoBenchmark database, a collaboration of 13 high-volume centers routinely per…
Usefulness of ileostomy defunctioning stoma after anterior resection of rectum on prevention of anastomotic leakage A retrospective analysis
2016
Anastomotic leakage is one of the major complications occurring after anterior resection of rectum. A defunctioning stoma is usually created routinely or on surgeons' discretion. The aim of this study was to investigate the usefulness of temporary ileostomy to prevent anastomotic leakage comparing the postoperative course of patients with and without defunctioning loop ileostomy.Patients that underwent anterior resection of rectum were recruited. 140 patients were enrolled and divided in two groups: patients without and with defunctioning loop ileostomy. Patients' characteristics and other useful data were recorded. A comparison between the two groups was made. The minimum follow-up was 11 …
Application prospects of silica core side-glowing optical fibers
2005
The side-emitting optical fibers are specially designed to stimulate leakage of the core-transmitted radiation via their side surfaces, so creating the effect of glowing tiny wires. The basic design concepts for this kind of optical fibers are discussed, as well as some of the present and potential future applications.
Early results of a low-profile stent-graft for thoracic endovascular aortic repair
2020
Purpose To assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies. Methods A retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019. Results 23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was a…
Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…
2012
Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…
Differential Leakage Factor in Electrical Machines Equipped with Asymmetrical Multiphase Windings: a General Investigation
2019
This paper presents an investigation in terms of degree of unbalance and leakage factor of electrical machines equipped with multiphase windings. The analysis has been carried out through 4800 combinations between slots/poles/phases/layers, analyzing the variability of the leakage factor for each condition and determining the optimal region for its minimization. The obtained results demonstrate that the leakage factor could be considerably reduced with the adoption of slightly asymmetrical windings, which represent a favorable option during the early design stage of electrical machines.
Assessing the effectiveness of Byssochlamys nivea and Scopulariopsis brumptii in pentachlorophenol removal and biological control of two Phytophthora…
2016
Bioremediation and biological-control by fungi have made tremendous strides in numerous biotechnology applications. The aim of this study was to test Byssochlamys nivea and Scopulariopsis brumptii in sensitivity and degradation to pentachlorophenol (PCP) and in biological-control of Phytophthora cinnamomi and Phytophthora cambivora. B. nivea and S. brumptii were tested in PCP sensitivity and degradation in microbiological media while the experiments of biological-control were carried out in microbiological media and soil. The fungal strains showed low PCP sensitivity at 12.5 and 25 mg PCP L(-1) although the hyphal size, fungal mat, patulin, and spore production decreased with increasing PCP…