Search results for "libration"

showing 10 items of 901 documents

High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment

2020

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.

Nuclear and High Energy PhysicsSpeichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsResolution (mass spectrometry)Physics::Instrumentation and Detectorsenergy resolutionFOS: Physical sciencesElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]KATRIN7. Clean energy01 natural sciencesAtomicneutrino massNuclear physicsParticle and Plasma Physicsconversion electronsMetastability0103 physical sciencesNuclearddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsSpectroscopyNuclear ExperimentPhysicsSpectrometerelectrostatic spectrometer010308 nuclear & particles physicsPhysicskrypton: decayMolecularInstrumentation and Detectors (physics.ins-det)krypton: nuclide530 PhysikcalibrationNuclear & Particles Physicsddc:3. Good healthBeamlineelectron: energy spectrumNeutrinoperformanceKATRIN
researchProduct

Measurement of the b hadron lifetime with the dipole method

1993

A measurement of the average lifetime of b hadrons has been performed with the dipole method on a sample of 260000 hadronic Z decays recorded with the ALEPH detector during 1991. The dipole is the distance between the vertices built in the opposite hemispheres. The mean dipole is extracted from all the events without attempting b enrichment. Comparing the average of the data dipole distribution with a Monte Carlo calibration curve obtained with different b lifetimes, an average b hadron lifetime of 1.51 +/- 0.08 ps is extracted. RI ANTONELLI, ANTONELLA/C-6238-2011; Buttar, Craig/D-3706-2011; Stahl, Achim/E-8846-2011; Passalacqua, Luca/F-5127-2011; Murtas, Fabrizio/B-5729-2012; St.Denis, Ric…

Nuclear and High Energy Physics[PHYS.HEXP] Physics [physics]/High Energy Physics - Experiment [hep-ex]Calibration curveElectron–positron annihilationMonte Carlo methodHadronElementary particleDiscrete dipole approximation01 natural sciencesinformationNuclear physicsALEPH Experiment0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]mutualisation.010306 general physicsALEPH experimentPhysics010308 nuclear & particles physicsPhysicsmediologyterritoryDipoleHigh Energy Physics::Experimentterritorial intelligenceParticle Physics - Experiment
researchProduct

Development of procedures for programmable proximity aperture lithography

2013

Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…

Nuclear and High Energy Physicsta114business.industryApertureComputer sciencemicrofluidicsScalable Vector GraphicsFaraday cupcomputer.file_formatMeV ion beam lithographyprogrammable proximity aperture lithography (PPAL)symbols.namesakeSoftwareOpticsion-fluencePosition (vector)CalibrationElectronic engineeringsymbolsbusinessInstrumentationLithographycomputerBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A large area detector for high-energy neutrons

1992

Abstract We present design studies, results of test measurements, and Monte Carlo simulations which served as a basis for the realization of a large area neutron detector (LAND). It has a front area of 2m×2m and a depth of 1 m, and features a multilayer structure of passive converter and active scintillator material. The detector is subdivided in independently operating paddles which allow time-of-flight and position measurement. An energy resolution of ΔT n / T n =5.3% for a flight path of 15 m and an overall detection efficiency of ϵ ≈ 1 is anticipated for neutrons with T n ≈ 1 GeV. The operation of LAND at the SIS facility of GSI is described.

Nuclear physicsPhysicsNuclear and High Energy PhysicsDetectorMonte Carlo methodCalibrationLarge Area Neutron DetectorNeutronScintillatorInstrumentationRealization (systems)Energy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Hypernuclear Spectroscopy at JLab Hall C

2010

Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…

Nuclear physicsPhysicsNuclear and High Energy PhysicsParticle physicsFull width at half maximumLuminosity (scattering theory)Electron spectrometerSpectrometerResolution (electron density)Calibrationhypernuclear; electroproduction; kaon spectrometer; electron spectrometerSpectroscopySpectral lineNuclear Physics A
researchProduct

Low-pT pion enhancement from partial thermalization in nuclear collisions

1991

Abstract We attribute the enhancement of pions measured at low transverse momenta and central rapidities in 200 A GeV nucleus-nucleus collisions to the partial thermal equilibration of a superdense pion fluid. Transport theory calculations are compared to recent S+S and O+Au data, and predictions are made for Pb+Pb.

Nuclear physicsPhysicsNuclear and High Energy PhysicsTransverse planePionThermalisationNuclear TheoryThermal equilibrationHigh Energy Physics::ExperimentTransport theoryNuclear ExperimentPhysics Letters B
researchProduct

Calibration of the PREdiction of DELIRium in ICu Patients (PRE-DELIRIC) Score in a Cohort of Critically Ill Patients: A Retrospective Cohort Study

2023

BACKGROUND: To predict delirium in intensive care unit (ICU) patients, the Prediction of Delirium in ICU Patients (PRE-DELIRIC) score may be used. This model may help nurses to predict delirium in high-risk ICU patients. OBJECTIVES: The aims of this study were to externally validate the PRE-DELIRIC model and to identify predictive factors and outcomes for ICU delirium. METHOD: All patients underwent delirium risk assessment by the PRE-DELIRIC model at admission. We used the Intensive Care Delirium Screening Check List to identify patients with delirium. The receiver operating characteristic curve measured discrimination capacity among patients with or without ICU delirium. Calibration abili…

Nursing PREDELIRIC Calibration ICUEmergency NursingCritical Care NursingSettore MED/45 - Scienze Infermieristiche Generali Cliniche E Pediatriche
researchProduct

Calibration of advanced Virgo and reconstruction of the gravitational wave signal h(t) during the observing run O2

2018

In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Three versions of the h(t) signal have been computed for the Virgo O2 run, an online version and two post-run reprocessed versions with improved detector calibration and reconstruction…

O2 observation runPhysics and Astronomy (miscellaneous)AstronomyAstrophysicsdetector: networkVIRGO: calibration01 natural sciencesGeneral Relativity and Quantum CosmologyPhysics Particles & FieldsHigh Energy Physics::Theorydetector: calibrationLIGOmirrorgravitational wavePhysicsQuantum Science & TechnologyPhysicsDetectorphotonAstrophysics::Instrumentation and Methods for AstrophysicsReconstruction algorithmMassless particleAmplitudeCalibration Advanced Virgo O2Physical SciencesCalibration[PHYS.GRQC]Physics [physics]/General Relativity and Quantum Cosmology [gr-qc]Advanced VirgoAstrophysics - Instrumentation and Methods for Astrophysicson-linereconstructioninterferometergravitational wave calibration reconstruction photon calibrator Virgo O2 observation runPhysics MultidisciplinaryFOS: Physical sciencesO2General Relativity and Quantum Cosmology (gr-qc)Astronomy & Astrophysicsgravitational radiation: direct detectionParticle detectorGeneral Relativity and Quantum Cosmology0103 physical sciencesCalibrationcalibration; gravitational wave; O2 observation run; photon calibrator; reconstruction; Virgo; Physics and Astronomy (miscellaneous)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Science & Technology010308 nuclear & particles physicsGravitational waveVirgogravitational radiationcalibration; gravitational wave; O2 observation run; photon calibrator; reconstruction; Virgocalibrationphoton calibratorLIGOgravitational radiation detectordetector: sensitivity* Automatic Keywords *network
researchProduct

Application of hybrid linear ion trap-high resolution mass spectrometry to the analysis of mycotoxins in beer

2011

This paper reports the application of liquid chromatography electrospray ionization ion trap-orbitrap mass spectrometry for the determination of 18 mycotoxins (aflatoxins, fumonisins, trichothecenes, ochratoxin A, sterogmatocystin, beauvaricin, zearalenone and zearalenol) in beer. The extraction procedure was carried out by solid phase extraction (SPE): SPE columns were conditioned with acetonitrile/methanol and water. Beer was loaded onto the column which was washed with water. In these conditions, the recoveries were more than 65% and the relative standard deviation (RSD) were below 18%. The lowest limits of quantification (LLOQ) ranged from 9 to 155 ng ml(-1). Matrix-matched calibration …

Ochratoxin AAflatoxinHealth Toxicology and MutagenesisElectrospray ionizationAnalytical chemistryToxicologyMass spectrometryMass Spectrometrychemistry.chemical_compoundLimit of DetectionLiquid chromatography–mass spectrometrymycotoxinsSolid phase extractionZearalenoneChromatography High Pressure LiquidChromatographyExtraction (chemistry)Public Health Environmental and Occupational HealthReproducibility of ResultsLC/MSGeneral ChemistryGeneral MedicineReference StandardschemistryCalibrationbeerFood Science
researchProduct

Direct Analysis of Psilocin and Muscimol in Urine Samples Using Single Drop Microextraction Technique In-Line with Capillary Electrophoresis

2020

The fully automated system of single drop microextraction coupled with capillary electrophoresis (SDME-CE) was developed for in-line preconcentration and determination of muscimol (MUS) and psilocin (PSC) from urine samples. Those two analytes are characteristic active metabolites of Amanita and Psilocybe mushrooms, evoking visual and auditory hallucinations. Study analytes were selectively extracted from the donor phase (urine samples, pH 4) into the organic phase (a drop of octanol layer), and re-extracted to the acidic acceptor (background electrolyte, BGE), consisting of 25 mM phosphate buffer (pH 3). The optimized conditions for the extraction procedure of a 200 &micro

OctanolAnalyteLiquid Phase MicroextractionCalibration curveAmanitacapillary electrophoresisPharmaceutical ScienceElectrolyteUrinesingle drop microextraction01 natural sciencesArticleAnalytical Chemistrylcsh:QD241-44103 medical and health scienceschemistry.chemical_compound0302 clinical medicineCapillary electrophoresislcsh:Organic chemistryLimit of DetectionDrug DiscoverymedicineHumans030216 legal & forensic medicinePhysical and Theoretical ChemistrypsilocinChromatographyChemistrygreen chemistry010401 analytical chemistryOrganic ChemistryElectrophoresis CapillaryHydrogen-Ion ConcentrationmuscimolurinePsilocybin0104 chemical sciencesDilutionChemistry (miscellaneous)PsilocinCalibrationHallucinogensSolventsMolecular MedicinePsilocybemedicine.drugMolecules
researchProduct