Search results for "libration"
showing 10 items of 901 documents
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
2020
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
Measurement of the b hadron lifetime with the dipole method
1993
A measurement of the average lifetime of b hadrons has been performed with the dipole method on a sample of 260000 hadronic Z decays recorded with the ALEPH detector during 1991. The dipole is the distance between the vertices built in the opposite hemispheres. The mean dipole is extracted from all the events without attempting b enrichment. Comparing the average of the data dipole distribution with a Monte Carlo calibration curve obtained with different b lifetimes, an average b hadron lifetime of 1.51 +/- 0.08 ps is extracted. RI ANTONELLI, ANTONELLA/C-6238-2011; Buttar, Craig/D-3706-2011; Stahl, Achim/E-8846-2011; Passalacqua, Luca/F-5127-2011; Murtas, Fabrizio/B-5729-2012; St.Denis, Ric…
Development of procedures for programmable proximity aperture lithography
2013
Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…
A large area detector for high-energy neutrons
1992
Abstract We present design studies, results of test measurements, and Monte Carlo simulations which served as a basis for the realization of a large area neutron detector (LAND). It has a front area of 2m×2m and a depth of 1 m, and features a multilayer structure of passive converter and active scintillator material. The detector is subdivided in independently operating paddles which allow time-of-flight and position measurement. An energy resolution of ΔT n / T n =5.3% for a flight path of 15 m and an overall detection efficiency of ϵ ≈ 1 is anticipated for neutrons with T n ≈ 1 GeV. The operation of LAND at the SIS facility of GSI is described.
Hypernuclear Spectroscopy at JLab Hall C
2010
Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…
Low-pT pion enhancement from partial thermalization in nuclear collisions
1991
Abstract We attribute the enhancement of pions measured at low transverse momenta and central rapidities in 200 A GeV nucleus-nucleus collisions to the partial thermal equilibration of a superdense pion fluid. Transport theory calculations are compared to recent S+S and O+Au data, and predictions are made for Pb+Pb.
Calibration of the PREdiction of DELIRium in ICu Patients (PRE-DELIRIC) Score in a Cohort of Critically Ill Patients: A Retrospective Cohort Study
2023
BACKGROUND: To predict delirium in intensive care unit (ICU) patients, the Prediction of Delirium in ICU Patients (PRE-DELIRIC) score may be used. This model may help nurses to predict delirium in high-risk ICU patients. OBJECTIVES: The aims of this study were to externally validate the PRE-DELIRIC model and to identify predictive factors and outcomes for ICU delirium. METHOD: All patients underwent delirium risk assessment by the PRE-DELIRIC model at admission. We used the Intensive Care Delirium Screening Check List to identify patients with delirium. The receiver operating characteristic curve measured discrimination capacity among patients with or without ICU delirium. Calibration abili…
Calibration of advanced Virgo and reconstruction of the gravitational wave signal h(t) during the observing run O2
2018
In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Three versions of the h(t) signal have been computed for the Virgo O2 run, an online version and two post-run reprocessed versions with improved detector calibration and reconstruction…
Application of hybrid linear ion trap-high resolution mass spectrometry to the analysis of mycotoxins in beer
2011
This paper reports the application of liquid chromatography electrospray ionization ion trap-orbitrap mass spectrometry for the determination of 18 mycotoxins (aflatoxins, fumonisins, trichothecenes, ochratoxin A, sterogmatocystin, beauvaricin, zearalenone and zearalenol) in beer. The extraction procedure was carried out by solid phase extraction (SPE): SPE columns were conditioned with acetonitrile/methanol and water. Beer was loaded onto the column which was washed with water. In these conditions, the recoveries were more than 65% and the relative standard deviation (RSD) were below 18%. The lowest limits of quantification (LLOQ) ranged from 9 to 155 ng ml(-1). Matrix-matched calibration …
Direct Analysis of Psilocin and Muscimol in Urine Samples Using Single Drop Microextraction Technique In-Line with Capillary Electrophoresis
2020
The fully automated system of single drop microextraction coupled with capillary electrophoresis (SDME-CE) was developed for in-line preconcentration and determination of muscimol (MUS) and psilocin (PSC) from urine samples. Those two analytes are characteristic active metabolites of Amanita and Psilocybe mushrooms, evoking visual and auditory hallucinations. Study analytes were selectively extracted from the donor phase (urine samples, pH 4) into the organic phase (a drop of octanol layer), and re-extracted to the acidic acceptor (background electrolyte, BGE), consisting of 25 mM phosphate buffer (pH 3). The optimized conditions for the extraction procedure of a 200 µ