Search results for "linear"
showing 10 items of 7165 documents
Identification of a specific type of PD from acoustic emission frequency spectra
2001
The paper presents an attempt to apply spectral analysis tools in processing acoustic emission (AE) pulses generated by partial discharge (FD). The experimental part of the paper describes spark gaps generating four types of PD and specifies parameters of measured acoustic signals and recalls the system used for measurement and analysis of the frequency spectra. Also, a spectral analysis procedure is presented, and frequency-domain descriptors characterizing AE pulses are defined. The results of the analysis are given both as time plots and amplitude and energy density spectra, related to values of the associated descriptors. The spectral analysis results cover AE pulses generated in system…
Computationally efficient dynamical analysis of optically driven injection-locked GaAs FET oscillators
1995
A computer-aided simulation technique for the dynamical analysis of a class of GaAs FET optically-driven injection-locked oscillators (ODILO's) is presented. By combining a measurement-derived nonlinear model of the illuminated transistor with a phasor-domain analysis method, a first-approximation - but phenomenologically complete - differential model of the synchronized oscillator is derived. Since amplitude and phase of waveform evolutions are directly addressed and evaluated in a stroboscopic-time scale, the calculation of the transient response to modulated input signals can be done in a more user-friendly and computationally efficient manner than possible through conventional time-doma…
Room acoustical parameters: A factor analysis approach
2009
Abstract In this study, we determined the most representative acoustical parameters for halls intended for verbal or music audition. Our study was carried out in nine halls of different shapes and designed for different uses. We measured the impulse response at a great number of points (many more than the minimum required by the ISO 3382 norm). From a physical viewpoint, all halls are enclosed three-dimensional areas. Our work hypothesis is that objective (measurable) acoustical parameters, or a combination of such parameters, must provide the acoustical information specific to each hall and must make it possible to grade each hall. Factor analysis was used to obtain these grading parameter…
High-pressure flow-injection assembly. Indirect determination of glycine by atomic absorption spectrometry.
1991
A procedure for the determination of glycine is described. The method is based on the reaction of the analyte with finely powdered, solid copper(II) carbonate in a continuous-flow assembly. The optimum experimental conditions of pH, temperature, sample volume, flow-rate, column length and internal diameter, and the linear range of calibration, were studied. Interference from foreign substances that accompany this amino acid in pharmaceutical formulations was studied, and the method was applied to the determination of glycine.
Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…
2010
A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…
A preliminary study on the stability of benzodiazepines in blood and plasma stored at 4 degrees C.
1997
An approach to determine the stability of benzodiazepines and some of their metabolites (n = 13) by means of a routinely applied gas chromatographic method using electron capture detection was made in this preliminary study. Validation data of the method are given. Spiked blood and plasma samples were stored at 4 degrees C and analysed at selected times up to 240 days. The concentrations of all analytes had decreased to at least 60% of the original levels at the end of the observation period. A clear pattern of breakdown could not be established. The data obtained suggest that results from long-term stored samples should be interpreted cautiously. Further investigations concerning the stabi…
Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.
2019
A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…
Computer simulations for bioequivalence trials: Selection of analyte in BCS class II and IV drugs with first-pass metabolism, two metabolic pathways …
2018
A semi-physiological two compartment pharmacokinetic model with two active metabolites (primary (PM) and secondary metabolites (SM)) with saturable and non-saturable pre-systemic efflux transporter, intestinal and hepatic metabolism has been developed. The aim of this work is to explore in several scenarios which analyte (parent drug or any of the metabolites) is the most sensitive to changes in drug product performance (i.e. differences in in vivo dissolution) and to make recommendations based on the simulations outcome. A total of 128 scenarios (2 Biopharmaceutics Classification System (BCS) drug types, 2 levels of KM Pgp, in 4 metabolic scenarios at 2 dose levels in 4 quality levels of t…
Development of the H-point standard additions method for analyte determinations in unknown matrix
1993
Abstract The development of the H-point standard additions method is proposed in order to obtain the unbiased analyte concentration when the matrix of the sample is completely unknown. A spectral region where the interferent behaviour can be considered linear at three wavelengths must be chosen. The method uses the analytical signal data at these three wavelengths, usually situated in the maxima region of the analyte. Two procedures are proposed in order to know and to locate this behaviour for the unknown interferent. Several binary and ternary mixtures of phenol, 4-chlorophenol and 4-chloro-3-methylphenol as representative examples have been assayed, with accurate (less than 3% relative e…
A mathematical model based on the limit dilution method to obtain linear calibration curves which eliminate the matrix effect in quantitative analysi…
1995
Abstract We propose a mathematical model from an analytical application viewpoint inspired in the limit dilution method. The theoretical development of the model and its results are given. The model shows that there is a linear relation between the inverse of fluorescence intensity and the inverse of the dilution factor; each analytic system (sample, diluent and analyte) is characterised by a general linear function which is easily obtained. The analytical applications arising from this linearity are of great importance in X-ray fluorescence analysis. The following immediate applications are proposed: direct procurement of the total correction factor Y/H, rapid calculation of the fluorescen…