Search results for "liquid"

showing 10 items of 4351 documents

Role of ambient light in the detection of contrast elements in digital dental radiography.

2018

Objective This study aimed to evaluate the effect of different ambient light levels on observer detection of small contrast differences in a contrast phantom by using a high-end liquid crystal display (LCD) monitor. Study Design An aluminum step wedge was converted into a contrast phantom by the addition of bore holes. Radiographic images of the contrast elements were presented to 20 observers. Images were displayed in random order under different ambient light levels (0, 50, 200, and 500 lux) twice, and the observers had to determine if contrast elements were visible. Sensitivity and specificity were determined to calculate areas under receiver operating characteristic curves and Friedmann…

Dental radiographyObserver (quantum physics)Lightmedia_common.quotation_subjectRadiographySensitivity and SpecificityImaging phantom030218 nuclear medicine & medical imagingPathology and Forensic Medicinelaw.invention03 medical and health sciences0302 clinical medicineOpticslawmedicineContrast (vision)HumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)media_commonObserver VariationLiquid-crystal displaymedicine.diagnostic_testReceiver operating characteristicbusiness.industryPhantoms Imaging030206 dentistryRadiography Dental DigitalLiquid CrystalsData DisplaySurgeryOral SurgerybusinessSensitivity (electronics)Oral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Specificity of deoxyribonuclease hydrolysis determined by high-performance liquid anion-exchange chromatography

1980

DeoxyribonucleasesChromatographyLymphomaIon exchangeChemistryOrganic ChemistryDeoxyribonucleaseDNANeoplasms ExperimentalGeneral MedicineChromatography Ion ExchangeBiochemistryCell LineAnalytical ChemistryDNA metabolismMiceHydrolysisBiochemistryAnimalsChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

An isocratic high-pressure liquid chromatographic purification method for radioactively labeled deoxyribonucleoside triphosphates.

1976

Abstract A method is described for the rapid purification of radioactively labeled deoxyribonucleoside tri­phosphates from their spontaneously emerging hydrolysis products deoxyribonucleoside diphosphate, deoxyribonucleoside monophosphate, and deoxyribonucleoside. The separations which are finished within 3 min or less are carried out on a 0.1X5 cm column filled with LiChrosorb-NH2 , using isocratic elution with 0.025 м potassium phosphate, pH 6 .8 , in a high-pressure liquid chromatograph at room temperature and a flow rate of 30 ml · h-1(flow velocity 63.7 cm·min-1).

Deoxyribonucleosidechemistry.chemical_compoundHydrolysisIsocratic elutionChromatographychemistryPotassium phosphateHigh pressureDeoxyribonucleotidesPurification methodsGeneral Biochemistry Genetics and Molecular BiologyChromatography High Pressure LiquidZeitschrift fur Naturforschung. Section C, Biosciences
researchProduct

TASK SPECIFIC IONIC LIQUIDS: CATALIZZATORI ECOCOMPATIBILI PER LA DEPOLIMERIZZAZIONE DELLE PLASTICHE

Depolymerization plastics Ionic Liquids UltrasoundSettore CHIM/06 - Chimica Organica
researchProduct

Critical assessment of ionization patterns and applications of ambient desorption/ionization mass spectrometry using FAPA-MS

2016

Ambient desorption/ionization mass spectrometry (MS) has gained growing interest during the last decade due to its high analytical performance and yet simplicity. Here, one of the recently developed ambient desorption/ionization MS sources, the flowing atmospheric-pressure afterglow (FAPA) source, was investigated in detail regarding background ions and typical ionization patterns in the positive as well as the negative ion mode for a variety of compound classes, comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides and alkaloids. A broad range of signals for adducts and losses was found, besides the usually emphasized detection of quasimolecular ions, i.e. […

Desorption electrospray ionizationChemical ionizationChemistry010401 analytical chemistryAnalytical chemistryAtmospheric-pressure chemical ionization010402 general chemistryMass spectrometry01 natural sciencesIon source0104 chemical sciencesAtmospheric-pressure laser ionizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationJournal of Mass Spectrometry
researchProduct

A new interface to couple thin-layer chromatography with laser desorption/atmospheric pressure chemical ionization mass spectrometry for plate scanni…

2005

An interface to allow on-line qualitative and quantitative full-plate detection and analysis of compounds separated by thin-layer chromatography (TLC) is presented. A continuous wave diode laser is employed as a desorption source. Atmospheric pressure chemical ionization mass spectrometry ionizes and subsequently identifies the desorbed sample molecules. Besides direct laser desorption on untreated TLC plates, graphite particles were used as a matrix to couple in the laser power and improve the efficiency of desorption.

Desorption electrospray ionizationChromatographyMatrix-assisted laser desorption electrospray ionizationChemistryOrganic ChemistryAnalytical chemistryEquipment DesignMass spectrometryIon sourceSoft laser desorptionAnalytical ChemistryAtmospheric-pressure laser ionizationSpecimen HandlingEquipment Failure AnalysisSystems IntegrationAtmospheric PressureSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationDirect electron ionization liquid chromatography–mass spectrometry interfaceSpectroscopyAmbient ionizationRapid communications in mass spectrometry : RCM
researchProduct

Determination of acrylamide in coffee and chocolate by pressurised fluid extraction and liquid chromatography-tandem mass spectrometry.

2007

A selective and sensitive procedure has been developed and validated for the determination of acrylamide in difficult matrices, such as coffee and chocolate. The proposed method includes pressurised fluid extraction (PFE) with acetonitrile, florisil clean-up purification inside the PFE extraction cell and detection by liquid chromatography (LC) coupled to atmospheric pressure ionisation in positive mode tandem mass spectrometry (APCI-MS-MS). Comparison of ionisation sources (atmospheric pressure chemical ionisation (APCI), atmospheric pressure photoionization (APPI) and the combined APCI/APPI) and clean-up procedures were carried out to improve the analytical signal. The main parameters aff…

Detection limitAcrylamideCacaoChromatographyAtmospheric pressureChemistryHealth Toxicology and MutagenesisExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistryAtmospheric-pressure chemical ionizationGeneral ChemistryIsotope dilutionToxicologyMass spectrometryTandem mass spectrometryCoffeeChemistry (miscellaneous)Liquid chromatography–mass spectrometrySpainTandem Mass SpectrometryFood ScienceChromatography LiquidFood additives and contaminants
researchProduct

Analysis of LSD in human body fluids and hair samples applying ImmunElute columns.

2000

Immunoaffinity extraction units (LSD ImmunElute) are commercially available for the analysis of lysergic acid diethylamide (LSD) in urine. The ImmunElute resin contains immobilized monoclonal antibodies to LSD. We applied the ImmunElute procedure to serum and also to human hair samples. For hair analysis the samples were first extracted with methanol under sonication. The extracts were then purified using the ImmunElute resin. LSD analysis was carried out with HPLC and fluorescence detection. The immunoaffinity extraction provides highly purified extracts for chromatographic analysis. The limit of detection (signal-to-noise ratio = 3) has been determined to be < 50 pg regardless of which sa…

Detection limitAdultMaleChromatographyAdolescentChemistryIllicit DrugsSonicationHair analysisExtraction (chemistry)UrineHigh-performance liquid chromatographyChromatography AffinityPathology and Forensic MedicineBody FluidsSubstance Abuse DetectionLysergic Acid DiethylamideAffinity chromatographyHumansGas chromatography–mass spectrometryLawChromatography High Pressure LiquidHairForensic science international
researchProduct

On-line analysis of carbonyl compounds with derivatization in aqueous extracts of atmospheric particulate PM10 by in-tube solid-phase microextraction…

2011

Abstract A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl–5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analys…

Detection limitAldehydesAqueous solutionChromatographyCapillary actionOrganic ChemistryReproducibility of ResultsGeneral MedicineParticulatesReference StandardsSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical ChemistryAcetonechemistry.chemical_compoundchemistryCapillary columnTube (fluid conveyance)Particulate MatterParticle SizeDerivatizationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Detection of banned drugs in sport by micellar liquid chromatography

1992

Abstract A rapid method for the determination of banned drugs in sport (including stimulants, anabolic steroids and diuretics) based on micellar liquid chromatography is proposed. The mobile phase is an aqueous solution of a surfactant (sodium dodecyl sulphate in this instance) and the stationary phase is octadecylsilica. The retention parameters of the drugs were established and the effect of a mobile phase organic modifier on the chromatographic behaviour of the compounds was studied. Improvements in efficiency were achieved by control of the temperature of the mobile phase. This method allows the direct injection of urine samples for the determination of drugs excreted free in urine: ami…

Detection limitAmiphenazoleChromatographyMethoxyphenamineChemistryMetandienoneClostebolBiochemistryAnalytical Chemistrychemistry.chemical_compoundMicellar liquid chromatographymedicineEnvironmental ChemistryEphedrineSpectroscopyPhenylpropanolaminemedicine.drugAnalytica Chimica Acta
researchProduct