Search results for "lithic"

showing 10 items of 392 documents

Study of elution behaviour with gradient voltage in CEC using methacrylate monolithic columns.

2010

A theoretical study on the retention behaviour and chromatographic performance of neutral solutes using a lauryl methacrylate-based monolithic column under voltage gradient mode in CEC was carried out. Through a flexible mathematical function based on a modified Gaussian model, the peak shape of compounds was firstly fitted under constant and gradient voltage. Using the peak shape parameters and retention time, the estimation of global chromatographic performance, efficiency and peak capacity under several voltage conditions was performed. The influence of voltage gradient on the separation efficiency is discussed and simple equations are presented to calculate retention and peak widths und…

Monolithic HPLC columnChemistryElutionClinical BiochemistryAnalytical chemistryTEST MixtureMethacrylateBiochemistryAnalytical Chemistrysymbols.namesakeCapillary ElectrochromatographysymbolsConstant voltageMethacrylatesConstant (mathematics)Gaussian network modelMathematicsVoltageElectrophoresis
researchProduct

Development of Methods for the Determination of Ts, T3s and Sterols in Vegetable Oils

2012

In this work, a CEC method using methacrylate ester-based monolithic columns was developed to determine Ts and T3s present in edible oils. The potential of this method to evaluate olive oil adulteration with lower-cost oils of a different botanical origin was also investigated. For these purposes, the following vegetable oils were used: soybean, sunflower, grapeseed, EVOO (Coosur), hazelnut (Guinama), corn (Hacendado) and red palm (Blue Bay).

Monolithic HPLC columnChemistryFood scienceSunflowerOlive oil
researchProduct

Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics.

2007

The following particulate and monolithic silica columns were implemented in a fully automated and flexible multidimensional LC/MS system with integrated sample clean-up, to perform the analysis of endogeneous peptides from filtered urine and plasma samples: restricted access sulphonic acid strong cation-exchanger (RAM-SCX) for sample clean-up, RP 18 Chromolith guard columns as trap columns and 100 microm I.D. monolithic RP 18 fused silica capillary columns as last LC dimension. The results show sufficient overall system reproducibility and repeatability. Implementation of monolithic silica columns added an additional flexibility with respect to flow rate variation and adjustment due to the …

Monolithic HPLC columnChromatographyChemistryOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineRepeatabilityReversed-phase chromatographyMass spectrometrySilicon DioxideBiochemistryHigh-performance liquid chromatographyMass SpectrometryAnalytical ChemistryLiquid chromatography–mass spectrometrySample preparationSolid phase extractionPeptidesChromatography LiquidJournal of chromatography. A
researchProduct

Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography

2008

Abstract In order to elucidate the role of the flow-through characteristics with regard to the column performance in high-performance liquid chromatography (HPLC) native and n -octadecyl bonded monolithic silica rods and columns, respectively of 100 mm length and 4.6 mm ID with mesopores in the range between 10 and 25 nm and macropores in the range between 0.7 and 6.0 μm were examined by mercury intrusion/extrusion, scanning electron microscopy, image analysis and permeability. The obtained data of the flow-through pore sizes and porosity values as well as surface-to-volume ratio of the stationary phase skeleton enabled to predict their influence to the chromatographic separation efficiency…

Monolithic HPLC columnChromatographyChemistryScanning electron microscopeSilica gelOrganic ChemistryAnalytical chemistryGeneral MedicinePorosimetryReversed-phase chromatographySilicon DioxideBiochemistryAnalytical ChemistrySeparation processchemistry.chemical_compoundMicroscopy Electron ScanningPorosityMesoporous materialPorosityChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Comprehensive pore structure characterization of silica monoliths with controlled mesopore size and macropore size by nitrogen sorption, mercury poro…

2005

The porosity of monolithic silica columns is measured by using different analytical methods. Two sets of monoliths were prepared with a given mesopore diameter of 10 and 25 nm, respectively and with gradated macropore diameters between 1.8 and 7.5 microm. After preparing the two sets of monolithic silica columns with different macro- and mesopores the internal, external and total porosity of these columns are determined by inverse size-exclusion chromatography (ISEC) using polystyrene samples of narrow molecular size distribution and known average molecular weight. The ISEC data from the 4.6 mm analytical monolithic silica columns are used to determine the structural properties of monolithi…

Monolithic HPLC columnChromatographyMacroporeScanning electron microscopeChemistryOrganic ChemistrySize-exclusion chromatographyAnalytical chemistrySilica GelMercuryGeneral MedicinePorosimetrySilicon DioxideBiochemistryAnalytical ChemistryAdsorptionMicroscopy Electron TransmissionChromatography GelMicroscopy Electron ScanningAdsorptionMesoporous materialPorosityGelsPorosityJournal of Chromatography A
researchProduct

Pore structural characterization of monolithic silica columns by inverse size-exclusion chromatography

2007

In this work, a parallel pore model (PPM) and a pore network model (PNM) are developed to provide a state-of-art method for the calculation of several characteristic pore structural parameters from inverse size-exclusion chromatography (ISEC) experiments. The proposed PPM and PNM could be applicable to both monoliths and columns packed with porous particles. The PPM and PNM proposed in this work are able to predict the existence of the second inflection point in the experimental exclusion curve that has been observed for monolithic materials by accounting for volume partitioning of the polymer standards in the macropores of the column. The appearance and prominence of the second inflection …

Monolithic HPLC columnChromatographyMacroporeSilica gelOrganic ChemistrySize-exclusion chromatographyAnalytical chemistryGeneral MedicineModels TheoreticalSilicon DioxideBiochemistryAnalytical Chemistrychemistry.chemical_compoundchemistryInflection pointChromatography GelRadius of gyrationPorosityPorous mediumPorosityJournal of Chromatography A
researchProduct

Textural characterization of native and n-alky-bonded silica monoliths by mercury intrusion/extrusion, inverse size exclusion chromatography and nitr…

2008

Native and n-alkyl-bonded (n-octadecyl) monolithic silica rods with mesopores in the range between 10 and 25 nm and macropores in the range between 1.8 and 6.0 microm were examined by mercury intrusion/extrusion, inverse size exclusion chromatography (ISEC) and nitrogen sorption. Our results reveal very good agreement for the mesopore size distribution obtained from nitrogen adsorption (in combination with an advanced NLDFT analysis) and ISEC. Our studies highlight the importance of mercury porosimetry for the assessment of the macropore size distribution and show that mercury porosimetry is the only method which allows obtaining a combined and comprehensive structural characterization of m…

Monolithic HPLC columnChromatographyNitrogenOrganic ChemistryAnalytical chemistrychemistry.chemical_elementSorptionMercuryGeneral MedicinePorosimetryMesoporous silicaSilicon DioxideBiochemistryAnalytical ChemistryMercury (element)AdsorptionchemistryChromatography GelExtrusionAdsorptionMesoporous materialPorosityJournal of Chromatography A
researchProduct

Spherical ordered mesoporous silicas and silica monoliths as stationary phases for liquid chromatography

2006

Ordered mesoporous silicas such as micelle-templated silicas (MTS) feature unique textural properties in addition to their high surface area (approximately 1000 m2/g): narrow mesopore size distributions and controlled pore connectivity. These characteristics are highly relevant to chromatographic applications for resistance to mass transfer, which has never been studied in chromatography because of the absence of model materials such as MTS. Their synthesis is based on unique self-assembly processes between surfactants and silica. In order to take advantage of the perfectly adjustable texture of MTS in chromatographic applications, their particle morphology has to be tailored at the microme…

Monolithic HPLC columnMaterials scienceAnalytical chemistryFiltration and Separation02 engineering and technology010402 general chemistryMolecular sieveMCM-4101 natural sciencesAnalytical Chemistrychemistry.chemical_compoundMCM-41Electrochromatography[CHIM.ANAL]Chemical Sciences/Analytical chemistrychemistry.chemical_classificationChromatographyChromatographySilica gelPolymer[CHIM.MATE]Chemical Sciences/Material chemistryMesoporous silica021001 nanoscience & nanotechnologyMonolithic silica0104 chemical scienceschemistryMCM-480210 nano-technologyMesoporous materialMesoporous silica
researchProduct

Development of Methods for the Classification of EVOOs According to Their Geographical Origin

2012

The aim of this work was to obtain the phenolic profiles of EVOOs by using a CEC method, and to evaluate the use of these profiles in the prediction of the geographical origin of these EVOO samples. For this purpose, monolithic columns containing LA and BDDA monomers were constructed.

Monolithic HPLC columnMaterials scienceGlobule sizeBiological system
researchProduct

Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

2017

[EN] In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch®), or mixtures of H2O2 and H2SO4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification…

Monolithic HPLC columnMicrobore column02 engineering and technology01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundSurface modificationQUIMICA ANALITICAEnvironmental ChemistryMonolith attachmentMonolithReversed-phase liquid chromatographyPolytetrafluoroethyleneSpectroscopychemistry.chemical_classificationChromatography Reverse-PhasegeographyChromatographygeography.geographical_feature_categoryPolytetrafluoroethyleneChemistry010401 analytical chemistryPolymer monolithEquipment DesignPolymer021001 nanoscience & nanotechnology0104 chemical sciencesChemical engineeringPolymerizationAttenuated total reflectionSurface modificationAlkylbenzenes0210 nano-technologyAnalytica Chimica Acta
researchProduct