Search results for "method."
showing 10 items of 13043 documents
Gaia -ESO Survey: Analysis of pre-main sequence stellar spectra
2015
This paper describes the analysis of UVES and GIRAFFE spectra acquired by the Gaia-ESO Public Spectroscopic Survey in the fields of young clusters whose population includes pre-main sequence (PMS) stars. Both methods that have been extensively used in the past and new ones developed in the contest of the Gaia-ESO survey enterprise are available and used. The internal precision of these quantities is estimated by inter-comparing the results obtained by such different methods, while the accuracy is estimated by comparison with independent external data, like effective temperature and surface gravity derived from angular diameter measurements, on a sample of benchmarks stars. Specific strategi…
Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes
2009
Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …
Use of the modified quick easy cheap effective rugged and safe sample preparation approach for the simultaneous analysis of type A- and B-trichothece…
2010
A suitable extraction and purification method for the simultaneous liquid chromatography-mass spectrometry (LC-MS) determination of five mycotoxins, three type A, diacetoxyscirpenol (DAS), T-2 toxin (T-2) and HT-2 toxin (HT-2), and two type B-trichothecenes, deoxynivalenol (DON) and nivalenol (NIV), has been optimised using a modified "Quick Easy Cheap Effective Rugged and Safe" (QuEChERS) method. Different solvents were studied in the extraction procedure to obtain better recoveries, which ranged from 86 to 108%, using a 85/15 (v/v) mixture of methanol/acetonitrile. The values obtained for recovery, repeatability and reproducibility of the optimized method are in agreement with Commission …
Dissemination of a Carbapenem-Resistant Acinetobacter baumannii Strain Belonging to International Clone II/Sequence Type 2 and Harboring a Novel AbaR…
2013
ABSTRACT An outbreak of hospital-acquired Acinetobacter baumannii infections, caused by a bla OXA-23 -positive carbapenem-resistant strain belonging to international clone II/ST2, was detected in Latvia. The strain was partially equipped with the armA gene and the intI1-aacA4-catB8-aadA1-qacE Δ 1 class 1 integron. In addition, the strain carried AbaR25, a novel AbaR4-like resistance island of ∼46,500 bp containing structures similar to the previously described AbaR22 and Tn 6167 islands. AbaR25 was characterized by the occurrence of a second copy of Tn 6022a interrupted by Tn 2006 carrying the bla OXA-23 gene.
Measurement of acoustic attenuation in South Pole ice
2010
Using the South Pole Acoustic Test Setup (SPATS) and a retrievable transmitter deployed in holes drilled for the IceCube experiment, we have measured the attenuation of acoustic signals by South Pole ice at depths between 190 m and 500 m. Three data sets, using different acoustic sources, have been analyzed and give consistent results. The method with the smallest systematic uncertainties yields an amplitude attenuation coefficient alpha = 3.20 \pm 0.57 km^(-1) between 10 and 30 kHz, considerably larger than previous theoretical estimates. Expressed as an attenuation length, the analyses give a consistent result for lambda = 1/alpha of ~1/300 m with 20% uncertainty. No significant depth or …
Air-Coupled Imaging Method Applied to the Study and Conservation of Paintings
2007
An air-coupled acoustical imaging method for the study of wooden panel paintings is presented. After a brief overview of the state of the art, an introduction is given regarding the production technique of the art object under investigation. The technology employed is described in detail, as well as the proposed method. After a feasibility campaign of experiments, real ancient paintings have been investigated by means of a through-transmission and a single-sided lay-out. Defects were imaged in all the objects examined and in both the configurations adopted
Archetypal analysis: an alternative to clustering for unsupervised texture segmentation
2019
Texture segmentation is one of the main tasks in image applications, specifically in remote sensing, where the objective is to segment high-resolution images of natural landscapes into different cover types. Often the focus is on the selection of discriminant textural features, and although these are really fundamental, there is another part of the process that is also influential, partitioning different homogeneous textures into groups. A methodology based on archetype analysis (AA) of the local textural measurements is proposed. AA seeks the purest textures in the image and it can find the borders between pure textures, as those regions composed of mixtures of several archetypes. The prop…
Technical Note: Prediction Models of Airborne Sound Insulation of Multilayer Materials with Viscoelastic Thin Sheets
2008
The growing introduction of new insulation materials in building acoustics has caused an increase of the importance of the prediction tools. Appropriate simulations allow strictly necessary laboratory measurements to be identified. In this way, costs are reduced. The demands of new legislation has resulted in the appearance of various software designed to facilitate prediction. The prediction models are based on different hypotheses: adaptation of impedances, spatial behaviour of spectral components, statistical energy distribution, the Finite Element Method (FEM), etc. Each of these models and methods offer advantages and contain limitations. In this paper, different models for prediction…
Mini-COVIDNet: Efficient Lightweight Deep Neural Network for Ultrasound Based Point-of-Care Detection of COVID-19
2021
Lung ultrasound (US) imaging has the potential to be an effective point-of-care test for detection of COVID-19, due to its ease of operation with minimal personal protection equipment along with easy disinfection. The current state-of-the-art deep learning models for detection of COVID-19 are heavy models that may not be easy to deploy in commonly utilized mobile platforms in point-of-care testing. In this work, we develop a lightweight mobile friendly efficient deep learning model for detection of COVID-19 using lung US images. Three different classes including COVID-19, pneumonia, and healthy were included in this task. The developed network, named as Mini-COVIDNet, was bench-marked with …
A SYMMETRIC AND POSITIVE DEFINITE BEM FOR 2-D FORCED VIBRATIONS
1997
A BEM formulation for 2D elastodynamics in the time domain has been presented. The formulation gives a resolving system that involves boundary displacements only. The stiffness and mass matrices of the boundary discretized body are frequency independent, symmetric and positive definite