Search results for "neuroradiology"

showing 10 items of 231 documents

Cumulative doses analysis in young trauma patients: a single-centre experience

2015

Multidetector computed tomography (MDCT) represents the main source of radiation expo- sure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT stud- ies have been observed in the young trauma population with an increase in radiation exposure. We have identi- fied 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radio- logical Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software ® . We…

AdultMalemedicine.medical_specialtyAdolescentPopulationDose distributionRadiation DosageEffective dose (radiation)030218 nuclear medicine & medical imagingYoung Adult03 medical and health sciences0302 clinical medicineMultidetector Computed TomographyMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingYoung adulteducationNeuroradiologyEffective doseeducation.field_of_studymedicine.diagnostic_testbusiness.industryAdsorbed dose; Cumulative doses; Effective dose; MDCT; Tissue-weighting factors; Radiology Nuclear Medicine and ImagingMDCTTissue-weighting factorInterventional radiologyGeneral MedicineCumulative doseSingle centreAdsorbed dose030220 oncology & carcinogenesisWounds and InjuriesFemaleRadiologyNuclear medicinebusinessLa radiologia medica
researchProduct

Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity

2010

To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…

AdultMalemedicine.medical_specialtyAdolescentStatistics as TopicSulfur HexafluorideContrast MediaSensitivity and SpecificityMicrobubbleLesionYoung AdultFocal nodular hyperplasia Ultrasonography Contrast media Microbubbles Liver diseasesmedicineHumansRadiology Nuclear Medicine and imagingLiver diseasesPhospholipidsAgedUltrasonographyNeuroradiologyObserver Variationmedicine.diagnostic_testbusiness.industryUltrasoundFocal nodular hyperplasiaReproducibility of ResultsEchogenicityInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseFocal Nodular HyperplasiaMicrobubblesFemaleRadiologymedicine.symptomSettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessContrast-enhanced ultrasoundEuropean Radiology
researchProduct

Study of neurinomas with ultrasound contrast media: review of a case series to identify characteristic imaging patterns

2011

The aim of this study was to evaluate whether there exists a characteristic distribution pattern of vessels within neurinomas that may be used to characterise this type of lesion by employing a contrast-specific ultrasound technique.Between January 2003 and May 2010, 66 suspected neurinomas were evaluated according to their sonographic features (solid fusiform mass with well-defined margins located in direct continuity with the nerve that was not always discernible and heterogeneous as a result of the presence of small cystic areas or calcifications). The lesions were examined using a sonographic contrast medium consisting of sulphur hexafluoride microbubbles and equipment with dedicated co…

AdultMalemedicine.medical_specialtyAdolescentSulfur HexafluorideContrast MediaUltrasound contrast mediaYoung AdultPower dopplerCharacteristic distributionPeripheral Nervous System NeoplasmsHumansMedicineRadiology Nuclear Medicine and imagingPhospholipidsAgedUltrasonographyNeuroradiologyAged 80 and overbusiness.industryUltrasoundGeneral MedicineMiddle AgedSchwannoma UltrasoundPower Doppler Imaging contrast mediaFemaleRadiologyUltrasonographybusinessNeurilemmomaLa radiologia medica
researchProduct

Influence of heart rate in the selection of the optimal reconstruction window in routine clinical multislice coronary angiography

2008

Purpose. The aim of our study was to assess the influence of heart rate on the selection of the optimal reconstruction window with 40-slice multidetector-row computed tomography (40-MDCT) coronary angiography. Materials and methods. We studied 170 patients (114 men, age 60 +/- 11.3 years) with suspected or known coronary artery disease with 40-MDCT coronary angiography. Patients [mean heart rate (HR) 62.9 +/- 9.3 bpm, range 42-94 bpm] were clustered in two groups (group A: HR <= 65 bpm; group B: HR >65 bpm). Multiphase reconstruction data sets were obtained with a retrospective electrocardiogram (ECG)-gated 40-MDCT coronary angiography scan from 0% to 95% every 5% of the R-R interval.…

AdultMalemedicine.medical_specialtyCoronary AngiographyHeart RateHeart rateImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingMultislicecardiovascular diseasesSelection (genetic algorithm)AgedNeuroradiologyAged 80 and overmedicine.diagnostic_testbusiness.industryUltrasoundWindow (computing)Interventional radiologyGeneral MedicineMiddle Agedcardiovascular systemFemaleTomographyRadiologyArtifactsTomography X-Ray ComputedbusinessRadiologia Medica
researchProduct

Detection of coronary artery calcifications predicting coronary heart disease: comparison of fluoroscopy and spiral CT.

1998

The aim of this study was to evaluate the clinical relevance of coronary artery calcifications detected by spiral CT, congruence with fluoroscopy (FS) and coronary angiography, and comparison with studies reporting on application of double-helical CT and ultrafast CT. Forty patients underwent spiral CT (2-mm slice thickness, table feed 3 mm/s), coronary angiography, and FS (performed in the usual manner). Stenosis and calcifications were evaluated semiquantitatively. Nineteen patients suffering from a stenosis ≥ 75 % were verified at coronary angiography. All had coronary artery calcification on spiral CT. Fluoroscopy did not detect 8 of 19 patients with a stenosis ≥ 75 % (1 vessel: n = 1; …

AdultMalemedicine.medical_specialtyHemodynamicsCoronary DiseaseConstriction PathologicCoronary AngiographySensitivity and SpecificityPredictive Value of TestsmedicineFluoroscopyHumansRadiology Nuclear Medicine and imagingSpiralNeuroradiologyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryCalcinosisInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseStenosismedicine.anatomical_structureFluoroscopyFemaleRadiologybusinessTomography X-Ray ComputedArteryCalcificationEuropean radiology
researchProduct

Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.

2003

The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…

AdultMalemedicine.medical_specialtyHypertension PulmonaryContrast MediaRisk AssessmentSensitivity and SpecificitySeverity of Illness IndexPredictive Value of TestsPreoperative CareMedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesNeuroradiologyAgedRetrospective StudiesThrombectomyPostoperative Caremedicine.diagnostic_testbusiness.industrymusculoskeletal neural and ocular physiologyUltrasoundInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseThrombosiseye diseasesHelical ctRadiographic Image EnhancementTreatment OutcomePulmonary VeinsPredictive value of testsAngiographyChronic DiseaseChronic thromboembolic pulmonary hypertensionFemaleRadiologybusinessPulmonary EmbolismTomography Spiral Computedpsychological phenomena and processesMagnetic Resonance AngiographyFollow-Up StudiesEuropean radiology
researchProduct

Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…

2009

This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…

AdultMalemedicine.medical_specialtyKnee InjuriesSeverity of Illness IndexmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingCompound imagingNeuroradiologyUltrasonographymedicine.diagnostic_testbusiness.industryUltrasoundReproducibility of ResultsPosterior cruciate ligament · Knee · Sonography · Real-time spatial compound sonography · Magnetic resonance imagingMagnetic resonance imagingInterventional radiologyGeneral Medicinemusculoskeletal systemMagnetic Resonance Imagingmedicine.anatomical_structurePosterior cruciate ligamentCase-Control StudiesHigh resolution ultrasonographyFemalePosterior Cruciate LigamentRadiologyUltrasonographybusinessLa Radiologia medica
researchProduct

Coronary calcium score and computed tomography coronary angiography in high-risk asymptomatic subjects: assessment of diagnostic accuracy and prevale…

2010

The aim of the study was to compare the coronary artery calcium score (CACS) and computed tomography coronary angiography (CTCA) for the assessment of non-obstructive/obstructive coronary artery disease (CAD) in high-risk asymptomatic subjects. Two hundred and thirteen consecutive asymptomatic subjects (113 male; mean age 53.6 +/- 12.4 years) with more than one risk factor and an inconclusive or unfeasible non-invasive stress test result underwent CACS and CTCA in an outpatient setting. All patients underwent conventional coronary angiography (CAG). Data from CACS (threshold for positive image: Agatston score 1/100/1,000) and CTCA were compared with CAG regarding the degree of CAD (non-obst…

AdultMalemedicine.medical_specialtyLumen (anatomy)Coronary Artery DiseaseCoronary AngiographyAsymptomaticRisk AssessmentCoronary artery diseaseYoung AdultRisk FactorsInternal medicinePositive predicative valuemedicinePrevalenceHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesRisk factorNeuroradiologyAgedbusiness.industrynutritional and metabolic diseasesCalcinosiscalcium scoreGeneral MedicineMiddle Agedmedicine.diseaseCoronary Calcium ScoreItalycardiovascular systemCardiologyFemaleRadiologymedicine.symptomSettore MED/36 - Diagnostica Per Immagini E RadioterapiaAgatston scorebusinessTomography X-Ray Computednon-obstructive coronary artery diseaseEuropean Radiology
researchProduct

EDSS correlated analysis of median nerve somatosensory evoked potentials in multiple sclerosis

2001

Median nerve somatosensory evoked potentials (SEP) were recorded in 30 patients with multiple sclerosis. The examined patients had an expanded disability status scale (EDSS) between 0 and 6. The primary cortical potential N20, the subcortical potentials P14, N13b, N13a and the peripheral potential P9 were recorded simultaneously. In 5 patients normal SEP were observed (group 1), and in 6 patients there were consecutive disturbances of the somatosensory pathway (group 3). In 19 patients subcortical potentials were abnormal or absent while the following potentials were normal or identified which pattern corresponds to amplification within CNS structures (group 2). The EDSS of groups 1 and 2 w…

AdultMalemedicine.medical_specialtyMultiple SclerosisNeurologyNeural ConductionDermatologyAudiologyEvoked Potentials SomatosensoryInternal medicinemedicineHumansAgedNeuroradiologyExpanded Disability Status ScaleMultiple sclerosisBrainGeneral MedicineMiddle Agedmedicine.diseaseMedian nerveMedian NervePeripheralPsychiatry and Mental healthSomatosensory evoked potentialCardiologyFemaleNeurology (clinical)NeurosurgeryPsychologyNeurological Sciences
researchProduct

Intracranial pressure and pressure volume relation in patients with subarachnoid haemorrhage (SAH)

1978

The development of the intracranial pressure after a subarachnoid haemorrhage was evaluated in 21 patients. A statistically significant relation between the intracranial pressure and the neurological findings was found, whereas vasospasms did not influence the intracranial pressure. In patients in a clinically critical condition, rhythmic pressure waves of a frequency of 1/minute were repeatedly observed.

AdultMalemedicine.medical_specialtyNeurologyAdolescentIntracranial PressureHumansMedicineIn patientAgedNeuroradiologyIntracranial pressuremedicine.diagnostic_testbusiness.industryInterventional radiologyMiddle AgedSubarachnoid HemorrhageCerebrospinal Fluid ShuntsIschemic Attack TransientAnesthesiaDrainagePressure volumeFemaleSurgerySubarachnoid haemorrhageNeurology (clinical)NeurosurgerybusinessActa Neurochirurgica
researchProduct