Search results for "nuclear medicine"

showing 10 items of 3573 documents

Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden

2008

OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…

musculoskeletal diseasesmedicine.medical_specialtymedicine.diagnostic_testBone densitybusiness.industrymedicine.medical_treatmentmusculoskeletal systemSurgerymedicine.anatomical_structureSpinal fusionmedicineOrthopedics and Sports MedicineSurgeryCortical boneQuantitative computed tomographyNuclear medicinebusinessCadaveric spasmCancellous boneDual-energy X-ray absorptiometryFixation (histology)Zeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Operator-Related Errors and Pitfalls in Dual Energy X-Ray Absorptiometry: How to Recognize and Avoid Them.

2020

Dual-energy X-ray absorptiometry (DXA) is the most common modality for quantitative measurements of bone mineral density. Nevertheless, errors related to this exam are still very common, and may significantly impact on the final diagnosis and therapy. Operator-related errors may occur during each DXA step and can be related to wrong patient positioning, error in the acquisition process or in the scan analysis. The aim of this review is to provide a practical guide on how to recognize such errors in spine and hip DXA scan and how to avoid them, also presenting some of the most common artifacts encountered in clinical practice.

musculoskeletal diseasesmedicine.medical_specialtymedicine.diagnostic_testComputer sciencePatient positioningPatient PositioningSpine030218 nuclear medicine & medical imagingClinical Practice03 medical and health sciences0302 clinical medicineOperator (computer programming)Absorptiometry PhotonBone Density030220 oncology & carcinogenesismedicineHumansOsteoporosisRadiology Nuclear Medicine and imagingMedical physicsDual-energy X-ray absorptiometryAcademic radiology
researchProduct

Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen für die Stentimplantation?

1990

Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the popliteal artery kinking will occur predominantly in the original segments of the vessel …

musculoskeletal diseasesmedicine.medical_specialtymedicine.diagnostic_testbusiness.industryKnee flexionFemoral arteryKnee JointPopliteal arterySurgeryContractilitymedicine.arteryInternal medicineArterial Occlusive DiseasesAngiographymedicineCardiologyStent implantationRadiology Nuclear Medicine and imagingbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Upper Limb Interventions.

2019

Ultrasound has been reported to be a quick, cheap, and effective imaging modality to guide the interventional procedures in the musculoskeletal system. The use of ultrasound results in increased accuracy of needle placement associated with a reduction of complications. In the upper limb, ultrasound-guided procedures are applied to joints and soft tissues around the shoulder, elbow, wrist, and hand. This article reviews the clinical and technical aspects of the most common procedures performed in this anatomic area.

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentElbowPsychological interventionWrist030218 nuclear medicine & medical imagingUpper Extremity03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationMedicineHumansRadiology Nuclear Medicine and imagingReduction (orthopedic surgery)Ultrasonography Interventionalmedicine.diagnostic_testbusiness.industryUltrasoundSoft tissueInterventional radiologyGeneral Medicinemedicine.anatomical_structure030220 oncology & carcinogenesisTendinopathyUpper limbbusinessRadiologic clinics of North America
researchProduct

Liver stiffness quantification in biopsy-proven nonalcoholic fatty liver disease patients using shear wave elastography in comparison with transient …

2021

Purpose: This study prospectively assessed the performance of liver stiffness measurements using point shear-wave elastography (p-SWE) in comparison with transient elastography (TE) in patients with biopsy-proven nonalcoholic fatty liver disease (NAFLD). Methods: Fifty-six consecutive adult patients with a histological diagnosis of NAFLD prospectively underwent TE and p-SWE on the same day. The median of 10 measurements (SWE-10), the first five (SWE-5), and the first three (SWE-3) measurements were analyzed for p-SWE. Liver biopsy was considered as the reference standard for liver fibrosis grade. Receiver operating characteristic (ROC) curves and areas under the ROC curves (AUROCs) were cal…

nonalcoholic fatty liver diseasemedicine.medical_specialtyGastroenterologySettore MED/01 - Statistica Medica030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineLiver stiffnessInternal medicineStatistical significanceBiopsyNonalcoholic fatty liver diseaseMedical technologymedicineRadiology Nuclear Medicine and imagingnonalcoholic steatohepatitisR855-855.5shear wave elastographymedicine.diagnostic_testReceiver operating characteristicbusiness.industryNonalcoholic fatty liver disease Nonalcoholic steatohepatitis Shear wave elastography Transient elastography Liver stiffnessmedicine.diseasetransient elastographyliver stiffnessLiver biopsyOriginal Article030211 gastroenterology & hepatologyElastographySettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessTransient elastographyUltrasonography
researchProduct

A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations

2021

The goal of this manuscript is to estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo codes of low-energy photon cross-sections (&lt;200 keV). Monte Carlo simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra are considered. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a go…

photoelectric effectPhotonbrachytherapyMonte Carlo methodFOS: Physical sciencesSpectral lineMonte Carlo simulations030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineDosimetryRadiology Nuclear Medicine and imagingRadiometryPhysicsPhotonsRadiological and Ultrasound TechnologyPhantoms ImagingUncertaintyEstimatorRadiusPhotoelectric effectPhysics - Medical Physics3. Good healthComputational physics030220 oncology & carcinogenesisAbsorbed doseMedical Physics (physics.med-ph)low energy physicsMonte Carlo Method
researchProduct

Problem-Based Learning in Professional Studies from the Physiotherapy Students’ Perspective

2018

The aim of the study was to investigate how physiotherapy students using a problem-based learning approach develop into experts during higher education, and answers the question: How do physiotherapy students at bachelor’s level understand the problem-based learning approach while learning to become professionals? PBL is examined using interpretative phenomenological analysis (IPA) of longitudinal data written by 15 voluntary students from two different higher education institutions and collected during 3.5 years. The main results on the new way of learning strengthen earlier conceptions of the importance of reflection in the learning process. The PBL method activates a reflection process b…

physiotherapy studentAdult and Continuing EducationProfessional studiesfysioterapia030218 nuclear medicine & medical imagingEducation03 medical and health sciences0302 clinical medicineComputingMilieux_COMPUTERSANDEDUCATIONproblem-based learningReflection (computer graphics)Vocational EducationMedical educationongelmalähtöinen oppiminenopiskelijatInformation seeking05 social sciencesPerspective (graphical)Professional development050301 educationHealth and Physical EducationProblem-based learningammatillinen kehitysEducational MethodsPsychology0503 educationprofessional development
researchProduct

Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis

2020

We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p &lt; 0.05). The number of additional S…

planar lymphoscintigraphySentinel lymph nodelcsh:MedicineSingle-photon emission computed tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinesentinel lymph node99mTc-labeled colloidsmedicinemelanomamedicine.diagnostic_testbusiness.industryMelanomalcsh:RGeneral MedicineOdds ratiomedicine.diseaseConfidence intervalbody regionsmeta-analysis<sup>99m</sup>Tc-labeled colloids030220 oncology & carcinogenesisRelative riskMeta-analysis99mTc-labeled colloids; melanoma; meta-analysis; planar lymphoscintigraphy; sentinel lymph node; single photon emission/computed tomographysingle photon emission/computed tomographyNuclear medicinebusinessEmission computed tomographyJournal of Clinical Medicine
researchProduct

Plasma Dynamics Characterization for Improvement of Resonantly Enhanced Harmonics Generation in Indium and Tin Laser-Produced Plasmas

2022

R.A.G. is grateful to H. Kuroda for providing the access to the laser facility. As a Center of Excellence, the Institute of Solid State Physics at the University of Latvia received funding from the European Union’s Horizon 2020 Framework Programme H2020-WIDESPREAD-01-2016-2017-TeamingPhase2 under grant agreement no. 739508, project CAMART².

plasma characterizationindium plasmalaser-induced ablationlaser-induced ablation; plasma characterization; indium plasma; tin plasma; resonance-induced enhancement of harmonics:NATURAL SCIENCES::Physics [Research Subject Categories]tin plasmaRadiology Nuclear Medicine and imagingresonance-induced enhancement of harmonicsInstrumentationAtomic and Molecular Physics and OpticsPhotonics
researchProduct

High Bias Voltage CZT Detectors for High-flux Measurements

2017

In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…

radiation detectorRadiology Nuclear Medicine and ImagingMaterials sciencePreamplifier02 engineering and technology01 natural scienceslaw.inventionlawpixel0103 physical sciencesInstrumentationNuclear and High Energy Physic010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleElectrical engineeringBiasing021001 nanoscience & nanotechnologyPhoton countingCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeElectronic Optical and Magnetic MaterialsCZTFull width at half maximumHigh Fluxhigh bias voltageOptoelectronicssemiconductor detector0210 nano-technologybusinessVoltage
researchProduct