Search results for "performance liquid chromatography"
showing 10 items of 649 documents
Isocratic high-performance liquid chromatographic determination of tryptophan in infant formulas.
1996
The application to infant formulas of a method for tryptophan determination by isocratic HPLC with UV detection at 254 nm, after derivatization with phenyl isothiocyanate, was studied. Protein was hydrolysed by barium hydroxide at 120 degrees C for 8 h, followed by derivatization with phenyl isothiocyanate, HPLC and UV detection at 254 nm. The optimum chromatographic conditions (pH, ionic strength of elution solvent and eluent ratio) were established. The analytical parameters (linearity, precision, accuracy of derivatization and limits of detection and quantification) were determined. The values obtained demonstrated that the method is useful for determining the tryptophan content of infan…
Comparative study of solvation parameter models accounting the effects of mobile phase composition in reversed-phase liquid chromatography
2007
Solvation parameter models relate linearly compound properties with five fundamental solute descriptors (excess molar refraction, dipolarity/polarizability, effective hydrogen-bond acidity and basicity, and McGowan volume). These models are widely used, due to the availability of protocols to obtain the descriptors, good performance, and general applicability. Several approaches to predict retention in reversed-phase liquid chromatography (RPLC) as a function of these descriptors and mobile phase composition are compared, assaying the performance with a set of 146 organic compounds of diverse nature, eluted with acetonitrile and methanol. The approaches are classified in two groups: those t…
Performance of a Chromolith RP-18e column for the screening of β-blockers
2009
The chromatographic performance of a monolithic column (Chromolith RP-18e) was comprehensively examined in the isocratic separation of ten beta-blockers, using ACN-water mobile phases, and compared with the performance of three microparticulate RP columns manufactured with different types of silica: Spherisorb ODS-2, Kromasil C18 and XTerra MS C18. The comparison considered the analysis time, selectivity, peak shape (column efficiency and asymmetry) and resolution, and was extended to a wide range of mobile phase compositions. The Chromolith column showed good performance for the analysis of beta-blockers with regard to the packed columns. In terms of selectivity and analysis time, the grea…
Prediction of peak shape in hydro-organic and micellar-organic liquid chromatography as a function of mobile phase composition
2007
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC…
Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…
2000
An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…
Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quad…
2015
The emerging trend towards high-resolution mass spectrometry (MS) alternatives was evaluated by the application of Orbitrap MS for the determination of acrylamide in coffee samples. The high resolving power of the Orbitrap MS provided the high selectivity and sensitivity that enabled quantitative analysis of acrylamide in complex matrices, such as coffee. Several sample preparation methods and scanning modes of the MS (full MS, t-SIM, t-MS2) were assessed in order to optimise parameters of the analytical method. The final procedure involved the extraction of acrylamide with acetonitrile, solid-phase extraction with dispersive primary secondary amine (PSA) and amino columns, and the detectio…
Micellar Liquid Chromatography: A Worthy Technique for the Determination of β-Antagonists in Urine Samples
1998
Several beta-antagonists (acebutolol, atenolol, celiprolol, labetalol, metoprolol, nadolol, propranolol) were determined in urine samples with fluorometric detection after direct injection, in less than 15 min, with a micellar mobile phase of 0.1 M sodium dodecyl sulfate (SDS), 15% propanol, and 1% triethylamine at pH 3. The limits of detection (38 criterion) were usually between 3 and 30 ng/mL. The addition of propanol and triethylamine and the reduction of the pH of the mobile phase improved the efficiency of the chromatographic peaks that was rather low in pure micellar eluents. The selection of the composition of the mobile phase was easily performed through the use of an interpretive p…
New spectrophotometric procedure for determining cefotaxime based on derivatization with 1,2-naphthoquinone-4-sulphonate into solid-phase extraction …
1998
Cefotaxime was derivatised with 1,2-naphthoquinone-4-sulphonate (NQS), extracted into solid-phase cartridges (C18) and detected using a UV-visible detection system. Optimum conditions for this new procedure were: hydrogencarbonate-carbonate buffer, pH 10.5, 5-min reaction time at 25 degrees C and an NQS concentration of 7.1x10(-3) mol l(-1). The accuracy and the precision of the liquid-solid procedure were tested. The procedure was used to measure cefotaxime in pharmaceutical and urine samples. The results obtained were contrasted with those reported for a HPLC method for urine samples. The generalized H-point standard additions method was used to measure cefotaxime in urine samples.
Quantification of the Fabry marker lysoGb3 in human plasma by tandem mass spectrometry
2011
Morbus Fabry is a hereditary metabolic disorder with low prevalence and late clinical manifestation. A defect in the α-galactosidase gene leads to lysosomal accumulation of the glycolipid globotriaosylceramide (Gb3). Gb3 may be used for monitoring of enzyme replacement therapy (ERT), but diagnostic sensitivity is limited. Recently, globotriaosylsphingosine (lysoGb3) was introduced as a promising new marker with significantly better sensitivity. For Fabry diagnosis, clinical studies and possible therapy monitoring, we established a fast and reliable LC-MS/MS assay for quantification of lysoGb3 in human plasma. Protein precipitation and glycolipid extraction from EDTA plasma was performed usi…
Pharmacokinetics and bioavailability of benperidol in schizophrenic patients after intravenous and two different kinds of oral application
1994
Pharmacokinetics and bioavailability of benperidol were determined in 13 schizophrenic patients after acute administration of 6 mg benperidol as an intravenous (i.v.) bolus injection, orally as liquid, and orally as tablets using a partially randomized cross-over design. Drug plasma levels were determined by high performance liquid chromatography with electrochemical detection and subjected to model independent pharmacokinetic analyses. After i.v. dosing the geometric means (mean-g) were 3.2 min for the distribution half-life, 5.80 h for the elimination half-life (t1/2 beta), 4.21 l/kg for the distribution volume, 7.50 h for the mean residence time (MRT), and 0.50 l/(h*kg) for the clearance…