Search results for "performance"
showing 10 items of 4457 documents
Target analysis and retrospective screening of mycotoxins and pharmacologically active substances in milk using an ultra-high-performance liquid chro…
2020
Milk is a nutritious food suitable for infants and adults, and it plays an important role in the human diet. However, it may also be a vehicle for food contaminants. In this report, we developed a method using ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-Q-Exactive Orbitrap HRMS; Thermo Fisher Scientific, Waltham, MA) for simultaneous identification of target pharmacologically active substances and mycotoxins in milk. We also used the Q-Orbitrap operating in full scan mode to identify other possible drugs and microbial metabolites that occurred in samples. Fifty-six commercially available milk samples from the Italian market were analyze…
Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis
2010
Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…
Assessment of oxidative damage to proteins and DNA in urine of newborn infants by a validated UPLC-MS/MS approach
2014
The assessment of oxidative stress is highly relevant in clinical Perinatology as it is associated to adverse outcomes in newborn infants. This study summarizes results from the validation of an Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS) method for the simultaneous quantification of the urinary concentrations of a set of endogenous biomarkers, capable to provide a valid snapshot of the oxidative stress status applicable in human clinical trials, especially in the field of Perinatology. The set of analytes included are phenylalanine (Phe), para-tyrosine (p-Tyr), ortho-tyrosine (o-Tyr), meta-tyrosine (m-Tyr), 3-NO2-tyrosine (3NO(2)-Tyr), 3-Cl-tyrosine (3Cl-T…
More about sampling and estimation of mercaptans in air samples
2013
[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…
An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.
2004
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied us…
Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry
2012
In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …
X-ray analysis on the nanogram to microgram scale using porous complexes
2012
X-ray single-crystal diffraction (SCD) analysis has the intrinsic limitation that the target molecules must be obtained as single crystals. Here we report a protocol for SCD analysis that does not require the crystallization of the sample. In our method, tiny crystals of porous complexes are soaked in a solution of the target, such that the complexes can absorb the target molecules. Crystallographic analysis clearly determines the absorbed guest structures along with the host frameworks. Because the SCD analysis is carried out on only one tiny crystal of the complex, the required sample mass is of the nanogram–microgram order. We demonstrate that as little as about 80 nanograms of a sample …
Identification of fish species by reversed-phase high-performance liquid chromatography with photodiode-array detection
1998
A method for the separation of sarcoplasmic fish proteins by RP-HPLC is described. The procedure revealed significant differences useful for reliable identification of fish species. Sixteen of the most common Finnish freshwater fish species were differentiated by species-specific HPLC chromatograms obtained using photodiode-array detection (PAD) at 200-350 nm. The analytical column was a Hi-Pore RP-304 reversed-phase column. The separation was performed by a linear gradient of acetonitrile and water with a small amount of trifluoracetic acid (TFA). Star-symbol plots were constructed from the chromatograms to visualize the data. Clearly different HPLC protein profiles for most fish species w…
Development and validation of a liquid chromatography tandem mass spectrometry method for the analysis of beta-agonists in animal feed and drinking w…
2010
A reproducible, sensitive and selective multiresidue analytical method for seven beta-agonists: clenbuterol (CBT), clenpenterol (CPT), ractopamine (RTP), brombuterol (BBT), mabuterol (MBT), mapenterol (MPT), and hydroxymethylclenbuterol (HMCBT) was developed and validated by using liquid chromatography tandem mass spectrometry (LC-MS/MS) in feed and drinking water samples. The validation was achieved according to the criteria laid down in the Commission Decision 2002/657/EC, however it was necessary to use minimum required performance limits (MRPLs) proposed by the Community Reference Laboratories (CRLs) due to the lack of maximum residue limits (MRLs) for beta-agonists. By setting up these…