Search results for "phantom"

showing 10 items of 196 documents

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

K-nearest neighbor driving active contours to delineate biological tumor volumes

2019

Abstract An algorithm for tumor delineation in positron emission tomography (PET) is presented. Segmentation is achieved by a local active contour algorithm, integrated and optimized with the k-nearest neighbor (KNN) classification method, which takes advantage of the stratified k-fold cross-validation strategy. The proposed approach is evaluated considering the delineation of cancers located in different body districts (i.e. brain, head and neck, and lung), and considering different PET radioactive tracers. Data are pre-processed in order to be expressed in terms of standardized uptake value, the most widely used PET quantification index. The algorithm uses an initial, operator selected re…

0209 industrial biotechnologyK-nearest neighborComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFDG and MET PET imagingStandardized uptake value02 engineering and technologyImaging phantomk-nearest neighbors algorithmActive contour algorithm020901 industrial engineering & automationArtificial IntelligenceRegion of interest0202 electrical engineering electronic engineering information engineeringSegmentationElectrical and Electronic EngineeringActive contour modelbusiness.industryProcess (computing)Pattern recognitionCancer segmentationBiological target volumeControl and Systems Engineering020201 artificial intelligence & image processingArtificial intelligencebusinessEnergy (signal processing)Engineering Applications of Artificial Intelligence
researchProduct

Tight Link Between Our Sense of Limb Ownership and Self-Awareness of Actions

2007

Background and Purpose— Hemiparetic stroke patients with disturbed awareness for their motor weakness (anosognosia for hemiparesis/-plegia [AHP]) may exhibit further abnormal attitudes toward or perceptions of the affected limb(s). The present study investigated the clinical relationship and the anatomy of such abnormal attitudes and AHP. Methods— In a new series of 79 consecutively admitted acute stroke patients with right brain damage and hemiparesis/ -plegia, different types of abnormal attitudes toward the hemiparetic/plegic limb (asomatognosia, somatoparaphrenia, anosodiaphoria, misoplegia, personification, kinaesthetic hallucinations, supernumerary phantom limb) were investigated. Re…

Malemedicine.medical_specialtyWeaknessHallucinationsHemiplegiaNeurological disorderFunctional LateralitySupernumerary phantom limbPhysical medicine and rehabilitationAsomatognosiaBody ImageAnosodiaphoriamedicineHumansAgedAged 80 and overCerebral CortexAdvanced and Specialized Nursingbusiness.industryAnosognosiaMiddle Agedmedicine.diseaseSurgeryParesisStrokeHemiparesisSomatoparaphreniaAcute DiseaseAgnosiaFemalePerceptionNeurology (clinical)medicine.symptomCardiology and Cardiovascular MedicinebusinessStroke
researchProduct

Importance of calibration for diameter and area determination by intravascular ultrasound

1996

Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglas) was performed using a mechanical IVUS system (HP console, 3.5 F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20 degrees C/37 degrees C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20 degrees C there was a constan…

medicine.medical_specialtyObservational errormedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundLumen (anatomy)Coronary VesselsCoronary arteriesCathetermedicine.anatomical_structureCalibrationIntravascular ultrasoundCirculatory systemHumansMedicineRadiology Nuclear Medicine and imagingRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalCardiac imagingBiomedical engineeringThe International Journal of Cardiac Imaging
researchProduct

Poor optical stability of molecular dyes when used as absorbers in water-based tissue-simulating phantoms

2019

Biomedical optical systems and models can be easily validated by the use of tissue-simulating phantoms. They can consist of water-based turbid media which often include inks (India ink and molecular dyes) as absorbers. Optical stability of commonly exploited inks under the influence of light, pH changes and the addition of TiO2 and surfactant, was studied. We found that the exposure to ultraviolet and visible light can crucially affect the absorption properties of molecular dyes. On average, absorption peaks decreased by 47.3% in 150 exposure hours. Furthermore, dilution can affect ink’s pH and by that, its decay rate under light exposure. When TiO2 was added to the phantoms, all molecular …

Materials sciencesurfactantturbid media02 engineering and technologymedicine.disease_cause01 natural sciencesIndia ink010309 opticsPulmonary surfactant0103 physical sciencesmedicinetissue-simulating phantomsmolecular dyesoptical spectroscopySpectroscopyAbsorption (electromagnetic radiation)Inkwell021001 nanoscience & nanotechnology3. Good healthDilutionoptical stabilityChemical engineering:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]Photocatalysis0210 nano-technologyUltravioletVisible spectrum
researchProduct

Mixture and dissolution of laser polarized noble gases: Spectroscopic and imaging applications

2012

Nuclear and High Energy PhysicsMagnetic Resonance SpectroscopyPhantoms ImagingSwineChemistryLasersAnalytical chemistryMolecular Dynamics SimulationLaserMagnetic Resonance ImagingNoble GasesBiochemistryAnalytical Chemistrylaw.inventionLaser polarizationlawSpin echoAnimalsHumansAtomic physicsDiffusion (business)SpectroscopyLungDissolutionSpectroscopyProgress in Nuclear Magnetic Resonance Spectroscopy
researchProduct

The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

2011

The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…

Radiation DosageComposite image filtersymbols.namesakeDigital imageOptical transfer functionMedian filterImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingGeneral DentistryMathematicsPixelPhantoms ImagingResearchGeneral MedicineRadiography Dental DigitalGaussian filterRadiographic Image EnhancementOtorhinolaryngologyGaussian noisesymbolsLinear ModelsArtifactsAlgorithmDigital filterAlgorithmsFiltrationDento maxillo facial radiology
researchProduct

A dosimetric study of Leipzig applicators.

2005

Purpose: To obtain the absolute dose-rate distribution in liquid water for all six cup-shaped Leipzig applicators by means of an experimentally validated Monte Carlo (MC) code. These six applicators were used in high-dose-rate (HDR) afterloaders with the “classic” and v2 192Ir sources. The applicators have an inner diameter of 1, 2, and 3 cm, with the source traveling parallel or perpendicular to the contact surface. Methods and materials: The MC GEANT4 code was used to obtain the dose-rate distribution in liquid water for the six applicators and the two HDR source models. To normalize the applicator output factors, a MC simulation for the “classic” and v2 sources in air was performed to es…

Cancer ResearchRadiationDosimeterbusiness.industryPhantoms Imagingmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyWaterRadiotherapy DosageIridium RadioisotopesImaging phantomKermaOpticsOncologyIonization chamberPerpendicularmedicineDosimetryRadiology Nuclear Medicine and imagingThermoluminescent DosimetrybusinessNuclear medicineMonte Carlo MethodInternational journal of radiation oncology, biology, physics
researchProduct

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

2006

Purpose: To study the influence of admixing inert buffer gases to laser-polarized 3 He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. Materials and Methods: The diffusion coefficient of 3 He was altered by admixing buffer gases of various molecular weights ( 4 He, N2, and SF6). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laserpolarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. Results: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted …

InertMaterials sciencePhantoms ImagingDiffusionPhysics::Medical PhysicsBuffer gasResolution (electron density)Contrast MediaReproducibility of ResultsPulse sequenceImage EnhancementSignalMolecular physicsHeliumSensitivity and SpecificityDiffusion Magnetic Resonance ImagingIsotopesRestricted DiffusionEffective diffusion coefficientHumansRadiology Nuclear Medicine and imagingGasesLungJournal of magnetic resonance imaging : JMRI
researchProduct

Power estimation for non-standardized multisite studies

2016

A concern for researchers planning multisite studies is that scanner and T1-weighted sequence-related biases on regional volumes could overshadow true effects, especially for studies with a heterogeneous set of scanners and sequences. Current approaches attempt to harmonize data by standardizing hardware, pulse sequences, and protocols, or by calibrating across sites using phantom-based corrections to ensure the same raw image intensities. We propose to avoid harmonization and phantom-based correction entirely. We hypothesized that the bias of estimated regional volumes is scaled between sites due to the contrast and gradient distortion differences between scanners and sequences. Given this…

Computer scienceCognitive Neurosciencecomputer.software_genreSensitivity and Specificity050105 experimental psychologyImaging phantomArticleSet (abstract data type)03 medical and health sciences0302 clinical medicineDistortionImage Interpretation Computer-AssistedCalibrationmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumans0501 psychology and cognitive sciencesSegmentationComputer Simulation10. No inequalityScalingModels Statisticalmedicine.diagnostic_test05 social sciencesContrast (statistics)BrainReproducibility of ResultsMagnetic resonance imagingEquipment DesignScale factorImage EnhancementMagnetic Resonance ImagingUnited StatesEquipment Failure AnalysisEuropeNeurologyOrdinary least squaresData miningFunction and Dysfunction of the Nervous SystemArtifactscomputer030217 neurology & neurosurgeryAlgorithms
researchProduct