Optimal control design of preparation pulses for contrast optimization in MRI

2017

Abstract This work investigates the use of MRI radio-frequency (RF) pulses designed within the framework of optimal control theory for image contrast optimization. The magnetization evolution is modeled with Bloch equations, which defines a dynamic system that can be controlled via the application of the Pontryagin Maximum Principle (PMP). This framework allows the computation of optimal RF pulses that bring the magnetization to a given state to obtain the desired contrast after acquisition. Creating contrast through the optimal manipulation of Bloch equations is a new way of handling contrast in MRI, which can explore the theoretical limits of the system. Simulation experiments carried out…

Nuclear and High Energy PhysicsComputer science[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingComputationRF pulsesBiophysics010402 general chemistry01 natural sciencesBiochemistry030218 nuclear medicine & medical imaging03 medical and health sciencesMagnetizationMice0302 clinical medicineOpticsRobustness (computer science)Image Interpretation Computer-AssistedImage Processing Computer-AssistedAnimalsComputer SimulationGray MatterMuscle Skeletal[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/Imagingbusiness.industryPhantoms ImagingContrast (statistics)BrainReproducibility of ResultsContrastCondensed Matter PhysicsOptimal controlImage EnhancementBloch equationsMagnetic Resonance ImagingWhite Matter0104 chemical sciencesWeightingRatsOptimal control[SPI.ELEC]Engineering Sciences [physics]/ElectromagnetismOptimal control designBloch equations[ SPI.ELEC ] Engineering Sciences [physics]/ElectromagnetismFemalebusinessAlgorithmAlgorithms
researchProduct

DNP in MRI: an in-bore approach at 1.5 T.

2011

Abstract We have used liquid state (“Overhauser”) Dynamic Nuclear Polarization (DNP) to significantly enhance the signal to noise ratio (SNR) of Magnetic Resonance Imaging (MRI). For the first time this was achieved by hyperpolarizing directly in the MRI-scanner field of 1.5 T in continuous flow mode and immediately delivering the hyperpolarized substance to the imaging site to ensure maximum contrast between hyperpolarized sample and sample at thermal polarization. We achieve a maximum absolute signal enhancement factor of 98; while the hyperpolarized sample is transported at a flow rate of up to 30 ml/h yielding an average flow speed up to 470 mm/s over a distance of approximately 80 mm. …

Nuclear and High Energy PhysicsContrast enhancementMagnetic Resonance Spectroscopymedicine.diagnostic_testContinuous flowChemistryPhantoms ImagingBiophysicsMagnetic resonance imagingSignal-To-Noise RatioCondensed Matter PhysicsPolarization (waves)BiochemistryMagnetic Resonance ImagingVolumetric flow rateSignal enhancementCyclic N-OxidesLiquid stateNuclear magnetic resonanceFlow velocitymedicineImage Processing Computer-AssistedSpin LabelsMicrowavesCopperJournal of magnetic resonance (San Diego, Calif. : 1997)
researchProduct

Mixture and dissolution of laser polarized noble gases: Spectroscopic and imaging applications

2012

Nuclear and High Energy PhysicsMagnetic Resonance SpectroscopyPhantoms ImagingSwineChemistryLasersAnalytical chemistryMolecular Dynamics SimulationLaserMagnetic Resonance ImagingNoble GasesBiochemistryAnalytical Chemistrylaw.inventionLaser polarizationlawSpin echoAnimalsHumansAtomic physicsDiffusion (business)SpectroscopyLungDissolutionSpectroscopyProgress in Nuclear Magnetic Resonance Spectroscopy
researchProduct

Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system.

2009

Abstract A technique for continuous production of solutions containing hyperpolarized 129Xe is explored for MRI applications. The method is based on hollow fiber membranes which inhibit the formation of foams and bubbles. A systematic analysis of various carrier agents for hyperpolarized 129Xe has been carried out, which are applicable as contrast agents for in vivo MRI. The image quality of different hyperpolarized Xe solutions is compared and MRI results obtained in a clinical as well as in a nonclinical MRI setting are provided. Moreover, we demonstrate the application of 129Xe contrast agents produced with our dissolution method for lung MRI by imaging hyperpolarized 129Xe that has been…

Nuclear and High Energy PhysicsPulmonary Circulationmedicine.diagnostic_testContinuous flowChemistryPhantoms ImagingBiophysicsLung perfusionMagnetic resonance imagingBiocompatible MaterialsMembranes ArtificialCondensed Matter PhysicsBiochemistryMagnetic Resonance ImagingImaging phantomSolutionsMembraneNuclear magnetic resonancemedicineImage Processing Computer-AssistedRespiratory MechanicsXenon IsotopesHyperpolarization (physics)LungJournal of magnetic resonance (San Diego, Calif. : 1997)
researchProduct

Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging

2018

Abstract Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous studies based on spectrophotometry showed valuable dosimetric features of these gels in terms of X-ray sensitivity and diffusion of the ferric ions produced after irradiation. In this study, MRI was performed on the gels at 1.5 T with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA gels were found to offer good linearity in the range of 0–10 Gy and a stable signal for several hours after irradiation. The sensitivi…

Nuclear and High Energy PhysicsXylenol orangeMaterials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariDose profileGlutaraldehydeImaging phantom030218 nuclear medicine & medical imagingMatrix (chemical analysis)Gel dosimeter03 medical and health scienceschemistry.chemical_compoundMagnetic resonance imaging0302 clinical medicineNuclear magnetic resonanceIrradiationGlutaraldehydeùInstrumentationPoly-vinyl alcoholX-ray radiotherapyDosimeterSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistry030220 oncology & carcinogenesisIonization chamberAgaroseGel dosimeter; Glutaraldehyde; Magnetic resonance imaging; Poly-vinyl alcohol; X-ray radiotherapy; Nuclear and High Energy Physics; InstrumentationSettore MED/36 - Diagnostica Per Immagini E RadioterapiaNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom

2019

Abstract This paper describes an automated method for extracting the apparent positions of fiducial points from 2D or 3D images of a phantom. We consider a 3D-lattice phantom for two main reasons: first, ease of manufacture and isotropy of its structure with respect to coordinate projections; second, a connected structure allowing to uniquely assess the adjacency relationship between fiducial points even if geometric distortions arising from main magnet inhomogeneity and gradient fields non-linearity is severe as observed in open-bore systems. In order to validate our proposed method and compare different choices for the parameters of our phantom (i.e. number and distance between grids and …

Offset (computer science)RegistrationImage qualityComputer scienceBiomedical EngineeringBiophysicsImage enhancement/restoration (noise and artifact reduction)Signal-To-Noise RatioImaging phantomPattern Recognition Automated030218 nuclear medicine & medical imaging03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineSoftwareRobustness (computer science)HumansComputer SimulationRadiology Nuclear Medicine and imagingMagnetic resonance imaging (MRI)Fiducial point localizationElectronic Data ProcessingPhantoms ImagingSettore ING-INF/03 - Telecomunicazionibusiness.industryAirSpherical harmonicsModels TheoreticalMagnetic Resonance ImagingPhantom designPersonal computerAdjacency listbusinessAlgorithmSoftware030217 neurology & neurosurgeryMagnetic Resonance Imaging
researchProduct

EP-1166: DVHs evaluation for vmat-imrt planning in cylindrical phantom DELTA4

2013

OncologyComputer sciencebusiness.industryRadiology Nuclear Medicine and imagingImrt planningRadiology Nuclear Medicine and imagingCylindrical phantomHematologyNuclear medicinebusinessRadiotherapy and Oncology
researchProduct

A Computational Study on Temperature Variations in MRgFUS Treatments Using PRF Thermometry Techniques and Optical Probes

2021

Structural and metabolic imaging are fundamental for diagnosis, treatment and follow-up in oncology. Beyond the well-established diagnostic imaging applications, ultrasounds are currently emerging in the clinical practice as a noninvasive technology for therapy. Indeed, the sound waves can be used to increase the temperature inside the target solid tumors, leading to apoptosis or necrosis of neoplastic tissues. The Magnetic resonance-guided focused ultrasound surgery (MRgFUS) technology represents a valid application of this ultrasound property, mainly used in oncology and neurology. In this paper

Optical fiberMaterials scienceInterferometric optical fibers MRgFUS Proton resonance frequency shift RBF neural networks Referenceless thermometry Temperature variationslcsh:Computer applications to medicine. Medical informaticsImaging phantomlcsh:QA75.5-76.95Article030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciencesinterferometric optical fibers0302 clinical medicinelawMedical imagingRadiology Nuclear Medicine and imaginglcsh:PhotographyElectrical and Electronic EngineeringReferenceless ther-mometryProton resonance frequencytemperature variationsbusiness.industryMRgFUSUltrasoundproton resonance frequency shiftFocused ultrasound surgerylcsh:TR1-1050Computer Graphics and Computer-Aided DesignRBF neural networksClinical PracticeInterferometryreferenceless thermometrylcsh:R858-859.7Computer Vision and Pattern Recognitionlcsh:Electronic computers. Computer sciencebusiness030217 neurology & neurosurgeryInterferometric optical fibers; MRgFUS; Proton resonance frequency shift; RBF neural networks; Referenceless ther-mometry; Temperature variationsBiomedical engineeringJournal of Imaging
researchProduct

Simultaneous imaging of absorption and scattering in dc diffuse optical tomography

2009

We present new results on the fundamental nonuniqueness issue in dc diffuse optical tomography (DOT) that resolve a long-standing conflict between theory and practice. Theoretically, scattering and absorption properties of the imaged media were proven to produce equivalent and thus indistinguishable effects. However, successful simultaneous reconstructions of both parameters were obtained in phantom experiments.

OpticsChemistryScatteringbusiness.industrybusinessAbsorption (electromagnetic radiation)Imaging phantomDiffuse optical imaging
researchProduct

2015

Background Accurate evaluation of immunostained histological images is required for reproducible research in many different areas and forms the basis of many clinical decisions. The quality and efficiency of histopathological evaluation is limited by the information content of a histological image, which is primarily encoded as perceivable contrast differences between objects in the image. However, the colors of chromogen and counterstain used for histological samples are not always optimally distinguishable, even under optimal conditions. Methods and Results In this study, we present a method to extract the bivariate color map inherent in a given histological image and to retrospectively o…

Pathologymedicine.medical_specialtyMultidisciplinarygenetic structuresColor visionbusiness.industrymedia_common.quotation_subjectDigital imagingDigital pathologyPattern recognitionContext (language use)Image processingBiologyImaging phantommedicineContrast (vision)Artificial intelligencebusinessHuemedia_commonPLOS ONE
researchProduct