Search results for "plates"
showing 10 items of 123 documents
Comparison of Two Solid-Phase Extraction (SPE) Methods for the Identification and Quantification of Porcine Retinal Protein Markers by LC-MS/MS
2018
Proper sample preparation protocols represent a critical step for liquid chromatography-mass spectrometry (LC-MS)-based proteomic study designs and influence the speed, performance and automation of high-throughput data acquisition. The main objective of this study was to compare two commercial solid-phase extraction (SPE)-based sample preparation protocols (comprising SOLAµ
A Multilayered Plate Theory with Transverse Shear and Normal Warping Functions
2016
A multilayered plate theory which takes into account transverse shear and normal stretching is presented. The theory is based on a seven-unknowns kinematic field with five warping functions. Four warping functions are related to the transverse shear behaviour, the fifth is related to the normal stretching. The warping functions are issued from exact three-dimensional solutions. They are related to the variations of transverse shear and normal stresses computed at specific points for a simply supported bending problem. Reddy, Cho-Parmerter and (a modified version of) Beakou-Touratier theories have been retained for comparisons. Extended versions of these theories, able to manage the normal s…
Reflections about the authentic document in "post mortem" fecundation
2018
[EN] The legislation on assisted reproduction contemplates the ¿post mortem¿ fecundation. Nevertheless, the document for the presentation of the assent raises some doubts in relation with the principle of party autonomy and the new technologies of the information and communication (ICTs). In the present work one thinks about these questions and one tries to contribute some solution of application in the Spanish legal system.
Complex power distribution analysis in plates covered with passive constrained layer damping patches
2012
International audience; The vibration of a plate partially covered with a passive constrained layer damping (PCLD) patch is studied from an energetic point of view. The damped plate is excited by an acoustic plane wave. The study is done with a numerical two-dimensional multilayer plate model. Results of the present model are compared to those obtained with three-dimensional finite element models. It is shown that the present model gives accurate results, even for the layer's inner behavior. It is less expansive in terms of computational cost; hence, it can simulate efficiently the structure for higher frequencies. Mathematical formulas for complex mechanical power are presented, and the li…
A NEW SYMMETRIC AND POSITIVE DEFINITE BOUNDARY ELEMENT FORMULATION FOR LATERAL VIBRATIONS OF PLATES
1997
Abstract A new symmetric and positive definite boundary element method in the time domain is presented for the dynamic analysis of thin elastic plates. The governing equations of the problem are obtained from a variational principle in which a hybrid modified functional is employed. The functional is expressed in terms of the domain and boundary basic variables in plate bending, assumed to be independent of each other. In the discretized model the boundary variables are expressed by nodal values, whereas the internal displacement field is modelled by a superposition of static fundamental solutions. The equations of motion are deduced from the functional stationarity conditions and they cons…
Generics: Ada 95 vs. C++ vs. Java 1.5
2005
Reconstruction of large mandibular and surrounding soft-tissue defects using distraction with bone transport.
2012
Reconstruction of large bone and soft-tissue defects of the inferior third of the face is possible using various surgical techniques. Patients who require these procedures need to be in good general health, may have sequelae linked to donor sites, and require several interventions to achieve good aesthetic and functional results. The aim of this study was to report outcomes in patients with large mandibular and soft-tissue defects treated using osteogenic distraction with bone transport. Between 2001 and 2008, 14 patients had distraction with bone transport. Most patients were men (92.1%). The mean age was 43.1 years. The average mandibular bone reconstruction was 13.6 cm. The mean duration…
Complex radial head and neck fractures treated with modern locking plate fixation
2019
Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…
Predicting the failure in distal femur fractures.
2018
Abstract Introduction The incidence of nonunion after fractures of the distal femur is up to 6%. The distal femoral nonunion is a disabling disease that needs complex steps in his treatment. Aim of our study is to find predicting factors of non-unions. Materials and methods We retrospectively analyzed 116 cases of distal femoral fractures and 20 cases of non-unions. In both surgeries we analyzed: accuracy of reduction, stability of fixation, hardware used, residual medial or lateral bone defect, use of autologous or heterologous bone grafts. Results Malreduction, particularly axial defect, associated with unbalanced fixation, and a medial cortical bone defect of greater or lesser extent wer…
Open Reduction and Internal Fixation of Low Subcondylar Fractures of Mandible Through High Cervical Transmasseteric Anteroparotid Approach
2009
Purpose The aim of the present study was to evaluate the functional and radiologic results of low subcondylar fracture fixation with modus TCP plates (Medartis, Basel, Switzerland) using a high cervical transmasseteric anteroparotid approach. Materials and Methods A prospective study was designed, enrolling all minimum-aged 15-year-old echomorphology patients presenting with displaced low subcondylar fracture with occlusion disturbances during a 41-month period. All fractures were fixed with modus TCP plates using high cervical transmasseteric anteroparotid approach. All patients underwent immediate physiotherapy and a 6-week liquid and semiliquid feeding period. Clinical and radiologic exa…