Search results for "preparation"

showing 10 items of 939 documents

Advanced Sample Preparation Techniques for MS Analysis

2015

ChromatographyChemistryExtraction (chemistry)Ms analysisSample preparationMass spectrometry
researchProduct

Profiling of endogenous peptides by multidimensional liquid chromatography: On-line automated sample cleanup for biomarker discovery in human urine.

2009

A simple and flexible system, employing a column switching technique, has been designed to allow the analysis of peptides and proteins smaller than 15 kDa by molecular weight in filtered urine samples by performing a direct on-column injection utilising simultaneous sample clean-up and trace enrichment. The positively charged peptides and small proteins in the sample are attracted to the inner, negatively charged pore structure of the RAM-SCX column while the larger proteins and uncharged or negatively charged compounds are excluded. After preconditioning with the biological sample, large amounts of sample can be injected. Several important and adjustable parameters for the proper use of a …

ChromatographyChemistryIon chromatographyAnalytical chemistryReproducibility of ResultsFiltration and SeparationHydrogen-Ion ConcentrationMass spectrometryHigh-performance liquid chromatographyAnalytical ChemistryDilutionSpecimen HandlingMolecular WeightMatrix-assisted laser desorption/ionizationAdsorptionSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationSolid phase extractionPeptidesBiomarkersChromatography LiquidJournal of separation science
researchProduct

Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges.

2005

Liquid chromatography-triple quadrupole/mass spectrometry (LC-TQ/MS) and liquid chromatography-quadrupole ion trap/mass spectrometry (LC-QIT/MS) for determining bupirimate, hexaflumuron, tebufenpyrad, buprofezin, pyriproxyfen, and fluvalinate in fruits have been compared. The differences in the mass spectra obtained by triple and ion trap quadrupoles are discussed, showing how both of them provide interesting features. The evaluation of the two instruments was carried out by ethyl acetate extraction of oranges spiked with the studied pesticides at LOQ and 10 times the LOQ. Results obtained by LC-TQ/MS correlated well with those obtained by LC-QIT/MS. Recoveries were 70-94% by LC-TQ/MS and 7…

ChromatographyChemistryOrganic ChemistryAnalytical chemistryPesticide ResiduesGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographyMass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerStandard additionMass spectrumSample preparationIon trapQuadrupole ion trapChromatography LiquidCitrus sinensisJournal of chromatography. A
researchProduct

Liquid chromatographic determination of aliphatic amines in water using solid support assisted derivatization with 9-fluorenylmethyl chloroformate

2002

A simple and sensitive method has been developed for the liquid chromatographic determination of short-chain aliphatic amines in water. Analytes are retained in solid-phase extraction (SPE) cartridges, and then derivatized by drawing an aliquot of the fluorogeneic reagent 9-fluorenylmethyl chloroformate (FMOC) through the cartridges. After a certain reaction time the derivatives formed are desorbed with acetonitrile. The collected extracts are then chromatographed on a LiChrospher 100 RP18 125 mm×4 mm i.d., 5 μm, column using an acetonitrile-water gradient. The influence of experimental conditions (SPE material, volume of sample, concentration of FMOC, time of reaction and pH) has been inve…

ChromatographyChemistryOrganic ChemistryClinical BiochemistryReversed-phase chromatographyChloroformateBiochemistryAnalytical Chemistrychemistry.chemical_compoundTap waterReagentSample preparationSolid phase extractionDerivatizationDimethylamine
researchProduct

Supercritical fluid extraction of pesticides

1989

The extraction behaviour of 10 μg samples of five pesticides and some related compounds from glass wool with supercritical CO2 has been investigated under several conditions (10 MPa, 20 MPa extraction pressure, 313 K, dry and water saturated CO2). The extraction fluid was decompressed over a line of little columns, filled with 3μ Si60 or RP18, and the amount of deposited material was analyzed by HPLC for each of these columns. Due to the progressive pressure/density reduction along the line, the solubility diminishes and hence the compounds are deposited according to their polarity/vapor pressure earlier or later on the line. Thus extraction and prefractionation of compounds of different po…

ChromatographyChemistryVapor pressureClinical BiochemistryExtraction (chemistry)Analytical chemistrySupercritical fluid extractionGlass woolGeneral MedicineBiochemistryHigh-performance liquid chromatographySupercritical fluidAnalytical ChemistryGeneral Materials ScienceSample preparationSolubilityFresenius' Zeitschrift f�r Analytische Chemie
researchProduct

Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?

2003

This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific …

ChromatographyChemistryVaporizationExtraction (chemistry)Analytical chemistryTrace elementSample preparationIsotope dilutionMass spectrometryBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryDilutionAnalytical and bioanalytical chemistry
researchProduct

Determination of α-Tocopherol in Plasma by High Performance Liquid Chromatography with Fluorescence Detection and Stability of α-Tocopherol under Dif…

2011

In order to study the clinical effects of the antioxidant alpha-tocopherol (tocofersolan, CAS 30999-06-5) a simple, robust, sensitive and reliable high performance liquid chromatography (HPLC) method using fluorescence detection for the daily measurement of alpha-tocopherol concentration in plasma is described. Several methods of HPLC analysis using fluorescence techniques are published, however, investigations of the stability of alpha-tocopherol during sample preparation under different conditions are relevant in the routine measurements and have to date not been reported. Therefore a modified method, both sensitive and robust, qualified for the day-by-day measurement of alpha-tocopherol …

ChromatographyChemistryalpha-TocopherolAnalytical chemistryReproducibility of Resultsfood and beveragesLiquid nitrogenHigh-performance liquid chromatographyFluorescenceFluorescence spectroscopyTocofersolanSpecimen Handlingchemistry.chemical_compoundSpectrometry FluorescenceDrug DiscoveryHumansSample preparationTocopherolQuantitative analysis (chemistry)Chromatography High Pressure LiquidArzneimittelforschung
researchProduct

Sunscreen analysis

2005

Although there are no official analytical methods for UV filters determination in sunscreen cosmetics, their maximum content are regulated by legislation, and then analytical methods to control these products are necessary. In this paper, analytical methods for UV filters determination in cosmetics, which can be found in the literature, are reviewed. The usefulness of the analytical methods, techniques and sample preparation is discussed. The analytical methods used for the determination of UV filters in other type of samples are commented upon. Moreover, a brief overview of the European Union legislation concerning UV filters is included.

ChromatographyChemistrybusiness.industrymedia_common.quotation_subjectUV filterBiochemistryCosmeticsAnalytical ChemistryEnvironmental Chemistrymedia_common.cataloged_instanceCritical surveySample preparationEuropean unionProcess engineeringbusinessSpectroscopyControl methodsmedia_commonAnalytica Chimica Acta
researchProduct

Possible interferences of mercury sulfur compounds with ethylated and methylated mercury species using HPLC-ICP-MS

2002

The HPLC-ICP-MS coupling technique is able to separate and detect methyl, ethyl and inorganic mercury isotopes specifically. An identification of ethyl mercury(+) is not possible when the widely used sodium tetraethylborate derivatisation method in combination with GC-AFS/AAS or ICP-MS techniques is performed because it contains ethyl groups.An unidentified compound with the same retention time as ethyl mercury was found in the HPLC chromatograms of industrial sewage samples and humic-rich soils of microcosm experiments after applying water vapour distillation. We also observed such unidentified peaks in samples of heavily contaminated sites in Eastern Germany, separated by HPLC fractionati…

ChromatographyChemistrychemistry.chemical_elementContaminationMass spectrometryBiochemistrySulfurHigh-performance liquid chromatographyAnalytical Chemistrylaw.inventionMercury (element)AdductlawEnvironmental chemistrySample preparationDistillationAnalytical and Bioanalytical Chemistry
researchProduct

Determination of Anticonvulsant Drugs in Pharmaceutical Preparations by Micellar Liquid Chromatography

2004

A micellar liquid chromatographic method for quality control of pharmaceutical preparations (capsules, pills, tablets, injections, drops, and suppositories) containing the anticonvulsant drugs acetazolamide, carbamacepine, chlordiazepoxide, diazepam, ethosuximide, phenytoin, phenobarbital, and zopiclone has been developed. This methodology involves the use of micellar solutions of cetyltrimethylammonium bromide (CTAB) as mobile phases and UV detection. The proposed approach is rapid and reproducible. Sample preparation only requires dissolution with micellar solvent and adequate dilution with the mobile phase before injection into the chromatographic system.

ChromatographyChemistrymedicine.medical_treatmentClinical Biochemistrytechnology industry and agriculturePharmaceutical ScienceBiochemistryDosage formAnalytical ChemistryChlordiazepoxideSolventEthosuximideAnticonvulsantMicellar liquid chromatographyMicellar solutionsmedicinelipids (amino acids peptides and proteins)Sample preparationmedicine.drugJournal of Liquid Chromatography & Related Technologies
researchProduct