Search results for "preparation"
showing 10 items of 939 documents
Improved sample preparation for the testosterone hydroxylation assay using disposable extraction columns
1992
The preparation of samples for injection into a high-performance liquid chromatograph from assay mixtures for the determination of cytochrome P-450-dependent testosterone hydroxylation has been substantially facilitated. By replacing the multiple cumbersome extraction steps of the conventional method with a single column extraction the time for sample preparation was reduced from hours to minutes. The new procedure also yields better recoveries for most of the testosterone metabolites than the original protocol. The use of extraction columns for sample preparation allows the simultaneous treatment of a large number of samples or even the automation of the whole assay procedure. The modified…
A theoretical plate model accounting for slow kinetics in chromatographic elution.
2011
The chromatographic elution has been studied from different perspectives. However, in spite of the simplicity and evident deficiencies of the plate model proposed by Martin and Synge, it has served as a basis for the characterization of columns up-to-date. This approach envisions the chromatographic column as an arbitrary number of theoretical plates, each of them consisting of identical repeating portions of mobile phase and stationary phase. Solutes partition between both phases, reaching the equilibrium. Mobile phase transference between the theoretical plates is assumed to be infinitesimally stepwise (or continuous), giving rise to the mixing of the solutions in adjacent plates. This yi…
Determination of quinolone residues in chicken and fish by capillary electrophoresis-mass spectrometry
2006
A specific pressure-assisted CE-MS method is described for the analysis of five quinolone residues. MS using a single quadrupole is compared with multiple-stage MS using a quadrupole IT (QIT-MS(n)). The procedure involves a common sample preparation by SPE on disposable cartridges. The most suitable electrolyte is 60 mM (NH(4))(2)CO(3) at pH 9.2. Single quadrupole does not provide enough fragmentation to confirm identities according to the current legislation. However, QIT-MS(n) achieves selective fragmentation. Using this method, danofloxacin, enrofloxacin, flumequine, ofloxacin, and pipemidic acid are analyzed in fortified samples of chicken and fish. Recoveries at levels of 50 ng/g were …
BEHAVIOUR OF GRAPHITIZED CARBON BLACK IN THE EXTRACTION OF POLAR NON-IONIC NITROGEN-CONTAINING PESTICIDES. A CHECKING OF HYPOTHESES
2000
Graphitized Carbon Black (GCB) extractive cartridges are evaluated for on-line coupling with a C8 analytical column to determine eleven carbamates and one carboximide pesticide from spiked deionized water at the 1.2 μg/L level. Several experiments were carried out to ascertain whether GCB saturation, pesticide degradation on the surface, existence of by-pass channels, mobility among the bulk cartridge, or strong retention on the surface interfere with the determination of pesticides. Problems in on-line CGB elution are partially solved by modifying the acetonitrile/water gradient to contain a front of 100% acetonitrile for a few seconds. Eluting the same GCB cartridges off-line with dichlor…
Solid phase extraction of amines
2005
Abstract The objective of this paper is to provide information about solid phase extraction (SPE) as an alternative to liquid–liquid extraction of amines from several matrices. Different sorbents ranging from non-polar phases, such as C 18 silica to more polar such as cyanopropylsilica (CN) have been tested for analysis of aliphatic amines as monoamines, diamines and polyamines. Phenylalkylamines such as amphetamine or methamphetamine and heterocyclic amines such as histamine or cephalosporins (which also contain a carboxylic group), have also been studied. The different steps involved in the extraction procedure have been tested (conditioning, retention, pre-concentration, washing and elut…
Rapid method for analysis of nicotine and nicotine-related substances in chewing gum formulations
1998
Abstract Based on environmental requirements and demands for a high throughput a rapid method for the analysis of nicotine and nicotine-related substances in chewing gum formulations was developed. The method is based on sample preparation through liquid–liquid extraction followed by reversed-phase HPLC using gradient elution. It allowed up to nine analytes to be determined within 15 min, including the sample preparation, and was considered as accurate and robust.
Micellar liquid chromatography: suitable technique for screening analysis.
2002
The screening capability of micellar liquid chromatography (MLC) is discussed using the reported chromatographic data of several sets of compounds (amino acids, beta-blockers, diuretics, phenethylamines, phenols, polynuclear aromatic hydrocarbons, steroids and sulfonamides) and new results (sulfonamides and steroids). The chromatographic data are treated with an interpretive optimisation resolution procedure to obtain the best separation conditions. Usually, the pH and the concentration of surfactant (sodium dodecyl sulfate, SDS, or cetyltrimethylammonium bromide) for the optimal mobile phase were 2.5-3 and0.12 M, respectively. The nature and concentration of organic solvent depended on the…
Solid-phase extraction of quaternary ammonium herbicides
2000
This paper highlights recent advances in the solid-phase extraction (SPE) of quaternary ammonium herbicides in water, soil, plant and biological samples. After a brief introduction summarizing the properties of quaternary ammonium herbicides and the difficulties involved in measuring them, attention is paid primarily to solid supports used for isolation and concentration, pre-treatments required for the different matrices, and eluents applied for quantitative desorption of these analytes. The determination techniques used after SPE and applications of the proposed SPE methodology are also briefly discussed.
Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography-electrospray ionization mass spectrometry and integrated sam…
2000
A novel restricted access cation exchanger with sulphonic acid groups at the internal surface was proven to be highly suitable in the sample clean up of peptides on-line coupled to HPLC-electrospray ionization (ESI)-MS. Neuropeptide Y (NPY) and several of its fragments in plasma were subjected to the sample clean-up procedure. The peptides were eluted by a step gradient from the restricted access column, applying 10 mM phosphate buffer pH 3.5 from 5 to 20% (v/v) of acetonitrile with 1 M NaCl and transferred to a Micra ODS II column (33x4.6 mm). The separation of the peptides and their fragments was performed by a linear gradient from 20 to 60% (v/v) acetonitrile in water with 0.1% formic ac…
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…