Search results for "push"
showing 10 items of 121 documents
SiC Power Switches Evaluation for Space Applications Requirements
2016
We have evaluated several SiC power switches available on the market, by defining and performing a global test campaign oriented to Space applications requirements, in order to define their main benefits but also the limits of current SiC technology. This allowed to identify a number of target applications where SiC could be used as a technology push for a new generation of space electronics units. Silicon devices qualified for space systems above 600V for the switches and 1200V for the rectifiers are not available due to performances limitations of Si. Among the typical static and dynamic characterization, we have performed temperature and power stress and HTRB tests. More remarkably, we h…
Exploiting chemical ecology to manage hyperparasitoids in biological control of arthropod pests
2020
Abstract Insect hyperparasitoids are fourth trophic level organisms that commonly occur in terrestrial food webs, yet they are relatively understudied. These top‐carnivores can disrupt biological pest control by suppressing the populations of their parasitoid hosts, leading to pest outbreaks, especially in confined environments such as greenhouses where augmentative biological control is used. There is no effective eco‐friendly strategy that can be used to control hyperparasitoids. Recent advances in the chemical ecology of hyperparasitoid foraging behavior have opened opportunities for manipulating these top‐carnivores in such a way that biological pest control becomes more efficient. We p…
The effect of photodynamic therapy and polymer solution containing nano-particles of Ag /ZnO on push-out bond strength of the sealers AH-Plus and MTA…
2017
BACKGROUND The aim of this in vitrostudy was to examine and compare the effect of photodynamic therapy and solution containing nano particles Ag/ZnO on adhesion of endodontic sealers to dentinal walls of human root canal. MATERIAL AND METHODS Ninty single-rooted human teeth were selected and their clinical crown was cut from the cemento-enamel junction zone. Canals were prepared by RaCe rotary system and the smear layer was removed using 17% EDTA and 5.25% NaOCl. Samples were randomly divided into two groups of AH Plus and MTA Fillapex based on the sealer type and each group based on antimicrobial method was divided into two sub-groups of photodynamic therapy and polymer containing nano par…
Assessment of Muscular Fitness as a Predictor of Flight Duty Limitation.
2018
Introduction The high acceleration (Gz) exposure among military pilots flying fighter aircraft has been associated with an increased risk for cervical and lumbar disorders. It has been suggested that an adequate level of physical performance could reduce the risk of experiencing these disorders. The Finnish Air Force has for several years used aerobic (bicycle ergometer) and muscular fitness tests (battery of five tests) in the selection process of military pilot candidates in order to evaluate their physical fitness level. The aim of the study was to determine if these selection phase tests and anthropometry measures can predispose those individuals who might be at risk of developing sever…
Small-Bowel Diagnosis in Patients with Familial Adenomatous Polyposis: Comparison of Push Enteroscopy, Capsule Endoscopy, Ileoscopy, and Enteroclysis
2009
BACKGROUND: Conventional upper endoscopy (EGD), EGD with side-view endoscope and ileoscopy are established procedures for endoscopic evaluation of patients with familial adenomatous polyposis (FAP). However, we still have little data on the frequency and relevance of adenomas in those parts of the small bowel which are not accessible to EGD and ileoscopy. Adenomas distal to the duodenum are found more often in FAP patients with known duodenal adenomas. The question is, whether these patients can benefit from additional endoscopic and/or radiographic examinations. METHODS: Between July 2001 and August 2006 we performed comparative small bowel studies with push enteroscopy (PE), capsule endos…
EMG and force production of the flexor hallucis longus muscle in isometric plantarflexion and the push-off phase of walking
2015
Large forces are generated under the big toe in the push-off phase of walking. The largest flexor muscle of the big toe is the flexor hallucis longus (FHL), which likely contributes substantially to these forces. This study examined FHL function at different levels of isometric plantarflexion torque and in the push-off phase at different speeds of walking. FHL and calf muscle activity were measured with surface EMG and plantar pressure was recorded with pressure insoles. FHL activity was compared to the activity of the calf muscles. Force and impulse values were calculated under the big toe, and were compared to the entire pressed area of the insole to determine the relative contribution of…
Myoelectric Activation and Kinetics of Different Plyometric Push-Up Exercises
2011
The kinetic and myoelectric differences between 3 types of plyometric push-ups were investigated. Twenty-seven healthy, physically active men served as subjects and completed both familiarization and testing sessions. During these sessions, subjects performed 2 series of 3 plyometric push-up variations in a counterbalanced order according to the following techniques: Countermovement push-ups (CPUs) were push-ups performed with the maximum speed of movement; jump push-ups (JPUs) were similar to clapping push-ups; and fall push-ups (FPUs) required kneeling subjects to drop and then attempt to return to their initial position. Vertical ground reaction forces were determined by using a force pl…
Selective activation of shoulder, trunk, and arm muscles: A comparative analysis of different push-up variants
2015
Context The push-up is a widely used exercise for upper limb strengthening that can be performed with many variants. A comprehensive analysis of muscle activation during the ascendant phase (AP) and descendant phase (DP) in different variants could be useful for trainers and rehabilitators. Objective To obtain information on the effect of different push-up variants on the electromyography (EMG) of a large sample of upper limb muscles and to investigate the role of the trunk and abdomen muscles during the AP and DP. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants Eight healthy, young volunteers without a history of upper extremity or spine injury.…
Bench Press and Push-up at Comparable Levels of Muscle Activity Results in Similar Strength Gains
2014
Electromyography (EMG) exercise evaluation is commonly used to measure the intensity of muscle contraction. Although researchers assume that biomechanically comparable resistance exercises with similar high EMG levels will produce similar strength gains over the long term, no studies have actually corroborated this hypothesis. This study evaluated EMG levels during 6 repetition maximum (6RM) bench press and push-up, and subsequently performed a 5-week training period where subjects were randomly divided into 3 groups (i.e., 6RM bench press group, 6RM elastic band push-up group, or control group) to evaluate muscle strength gains. Thirty university students with advanced resistance training …
Arithmetical Analysis of Biomolecular Finite Automaton
2013
In the paper we present a theoretical analysis of extension of the finite automaton built on DNA (introduced by the Shapiro team) to an arbitrary number of states and symbols. In the implementation we use a new idea of several restriction enzymes instead of one. We give arithmetical conditions for the existence of such extensions in terms of ingredients used in the implementation.