Search results for "range"
showing 10 items of 4508 documents
Impact of quality of life related to foot problems : a case-control study
2021
AbstractFoot problems are highly prevalent conditions, being a frequent reason for medical and podiatric consultation. The aim of this study was to compare the differences of quality of life (QoL) related to foot health in people with and without the presence of foot problems. A case–control study was carried out in an outpatient centre, where a clinician recorded data related to sociodemographic and clinical characteristics. In addition, self-reported data on foot health-related quality of life were recorded using the Spanish version of the Foot Health Status Questionnaire. The sample consisted of 498 participants (249 cases and 249 controls), with a median age of 30 years and an interquar…
Hip Muscle Strength Recovery after Hip Arthroscopy in a Series of Patients with Symptomatic Femoroacetabular Impingement
2014
International audience; Purpose: The aim of the study was to prospectively evaluate hip muscle strength in a series of patients with symptomatic FAI after hip arthroscopy. Methods: Hip muscle strength of eight patients (age: 29 +/- 10 years) was evaluated preoperatively and 2.5 years after hip arthroscopy, and was compared to eight matched controls. Maximal voluntary contraction (MVC) strength was measured for all hip muscle groups. At follow-up, we used the symptom-specific well-being outcome to assess the acceptability of the health state related to the hip. Results: Patients showed MVC strength increases for all hip muscles (9-59%, P<.05). At follow-up, only hip flexor MVC strength was l…
Concurrent Criterion-related Validity, Reliability, and Responsiveness to Treatment of the Figure-of-Four Position for Measurement of Anterior Hip Jo…
2018
Abstract Objective The objective of this study was to examine the intra- and intertester reliability, concurrent criterion-related validity, and responsiveness to treatment of the “figure-of-four” position. Methods A total of 52 asymptomatic male soccer players participated in this study. The intraclass correlation coefficient (2, 1) was used to determine intra- and intertester reliability of the figure-of-four position. Pearson product moment correlation coefficients examining the association between the figure-of-four position and goniometric measurements of hip extension and external rotation were used to establish concurrent validity. To evaluate responsiveness to treatment, the figure-…
Complex radial head and neck fractures treated with modern locking plate fixation
2019
Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…
Predicting the failure in distal femur fractures.
2018
Abstract Introduction The incidence of nonunion after fractures of the distal femur is up to 6%. The distal femoral nonunion is a disabling disease that needs complex steps in his treatment. Aim of our study is to find predicting factors of non-unions. Materials and methods We retrospectively analyzed 116 cases of distal femoral fractures and 20 cases of non-unions. In both surgeries we analyzed: accuracy of reduction, stability of fixation, hardware used, residual medial or lateral bone defect, use of autologous or heterologous bone grafts. Results Malreduction, particularly axial defect, associated with unbalanced fixation, and a medial cortical bone defect of greater or lesser extent wer…
Salivary MMP-9 in the detection of oral squamous cell carcinoma
2017
Background Oral squamous cell carcinoma (OSCC) is the most common malignant tumour of the oral cavity. Detection of OSCC is currently based on clinical oral examination combined with histopathological evaluation of a biopsy sample. Direct contact between saliva and the oral cancer makes measurement of salivary metalloproteinase- 9 (MMP-9) an attractive alternative. Material and Methods In total, 30 OSCC patients and 30 healthy controls were included in this prospective study. Saliva samples from both groups were collected, centrifuged and supernatant fluid was subjected to ELISA for assessment of MMP-9. The median salivary MMP-9 values with interquartile range (IQR) of OSCC patients and the…
The effect of MPEG audio compression on multidimensional set of voice parameters
2002
The MPEG-1 Layer 3 compression schema of audio signal, or commonly known as mp3, has caused a great impact in recent years as it has reached high compression rates while also conserving a high sound quality. Previous listening tests have shown that music and speech samples compressed at high bitrates are virtually indistinguishable from the original samples, but very little is known about how compression acoustically affects the voice signal. In Experiment 1 the spectral composition of original and compressed speech signals were analyzed by means of the Long-Term Average Spectrum using the Computerized Speech Laboratory (Kay Elemetrics Corp. (Pine Brook, NJ, USA)). In Experiment 2 a set of …
Proactive interference of a sequence of tones in a two-tone pitch comparison task
2000
Subjects compared pitches of a standard tone and a comparison tone separated by 1,300-3,000 msec and responded according to whether the comparison tone sounded higher or lower in pitch than the standard tone. Three interfering tones at 300-msec intervals were presented before each pair of tones. Their pitch range varied, being either below or above the pitch of the standard tone; in some of the trials, their pitches were identical to the pitch of the standard tone (no interference). The highest error rate in performance was found when the interfering tones and the comparison tone deviated in the same direction in pitch from the standard tone. In turn, their deviations in the opposite direct…
Late seizures in cerebral venous thrombosis
2020
ObjectiveTo examine the incidence, characteristics, treatment, and predictors of late seizures (LS) after cerebral venous thrombosis (CVT), we described these features in a registry of 1,127 patients with CVT.MethodsWe included consecutive adult patients from an international consortium of 12 hospital-based CVT registries. We excluded patients with a history of epilepsy or with <8 days of follow-up. We defined LS as seizures occurring >7 days after diagnosis of CVT. We used multivariable Cox regression to identify predictors of LS.ResultsWe included 1,127 patients with CVT. During a median follow-up of 2.0 years (interquartile range [IQR] 1.0–6.3), 123 patients (11%) experienced ≥1 LS…
Somatotopic arrangement of sudomotor axon reflex sweating in humans
2005
Impaired sweating may be one of the first symptoms in neuropathies, and therefore the evaluation of sweating might facilitate their early detection. Sudomotor axon reflexes can be quantified by two different methods: quantitative sudomotor axon reflex testing (QSART) measures the amount of local sweating, whereas staining with the iodine starch reaction assesses the extension of the sudomotor axon reflex area. The aim of our study was to compare both tests at three different sites on the leg: foot, lower leg and thigh.QSART and iodine starch staining after iontophoretic stimulation with acetylcholine were performed on 15 male volunteers (mean age: 25; range 24-27 years) on the left resp. th…