Search results for "reliability"
showing 10 items of 1563 documents
Reliability of a new analysis to compute time to stabilization following a single leg drop jump landing in children.
2019
Although a number of different methods have been proposed to assess the time to stabilization (TTS), none is reliable in every axis and no tests of this type have been carried out on children. The purpose of this study was thus to develop a new computational method to obtain TTS using a time-scale (frequency) approach [i.e. continuous wavelet transformation (WAV)] in children. Thirty normally-developed children (mean age 10.16 years, SD = 1.52) participated in the study. Every participant performed 30 single-leg drop jump landings with the dominant lower limb (barefoot) on a force plate from three different heights (15cm, 20cm and 25cm). Five signals were used to compute the TTS: i) Raw, ii…
Naturalistic study on the usage of smartphone applications among Finnish drivers
2018
We present results from a naturalistic study that tracked how Finnish drivers use their smartphones while on the move. We monitored 30 heavy in-car smartphone users in Finland during June–September 2016, recording the times that they used their phones, the application used at the time of touch (calls excluded), the location and driving speed. Touches per time unit were used as a proxy for estimating visual-manual distraction due to visual-manual tasks. Our data set allows the determining of whether drivers use their phones differently on varying road types (highway, main road, local rural road, urban road). We found that the road type has an effect on phone use but the effect is contrary to…
Long-term clinical and radiographic outcomes and patient satisfaction after adult spinal deformity correction
2018
Background and Aims: Adult spinal deformity surgery has increased with the aging population and modern surgical approaches, although it has high complication and reoperation rates. The permanence of radiographic correction, mechanical complications, predictive factors for poor patient-reported outcomes, and patient satisfaction were analyzed. Material and Methods: A total of 79 adult patients were retrospectively analyzed at baseline and 1–9 years after adult spinal deformity correction between 2007 and 2016. Patient-reported outcomes (Oswestry Disability Index, visual analog scale, and Scoliosis Research Society–30 scores), changes in radiographic alignment, indications for reoperation, pr…
Sleep and sleepiness in shift-working tram drivers
2020
Driver sleepiness contributes to traffic accidents. However, sleepiness in urban public transport remains an understudied subject. To fill this gap, we examined the sleepiness, sleep, and on-duty sleepiness countermeasures (SCMs) in 23 tram drivers working morning, day, and evening shifts for three weeks. Sleepiness was measured using Karolinska Sleepiness Scale (KSS). Nocturnal total sleep time (TST) was measured with wrist actigraphy. SCMs and naps were self-reported with a smartphone application. Caffeine and napping were considered effective SCMs. Severe sleepiness (KSS >= 7) was observed in 22% of shifts with no differences between shift types. Rest breaks were associated with slight r…
Alcohol-impaired Walking in 16 Countries: A Theory-Based Investigation.
2021
Alcohol is a global risk factor for road trauma. Although drink driving has received most of the scholarly attention, there is growing evidence of the risks of alcohol-impaired walking. Alcohol-impaired pedestrians are over-represented in fatal crashes compared to non-impaired pedestrians. Additionally, empirical evidence shows that alcohol intoxication impairs road-crossing judgements. Besides some limited early research, much is unknown about the global prevalence and determinants of alcohol-impaired walking. Understanding alcohol-impaired walking will support health promotion initiatives and injury prevention. The present investigation has three aims: (1) compare the prevalence of alcoho…
Reproducibility of pulse wave velocity and augmentation index derived from non-invasive occlusive oscillometric tonometry analysis in adolescents
2018
The aim of this study was to investigate the short-term reproducibility of aortic pulse wave velocity (PWVao) and augmentation index (AIx%) assessed by the non-invasive oscillometric device. Altogether of 55 (19 boys, 36 girls) adolescents 16-19-years-of-age participated in the study. PWVao and AIx% were measured during the same laboratory visit at 2 min intervals using the Arteriograph™ device. Peak oxygen uptake (VO2peak ) was assessed by the maximal exercise test on a cycle ergometer and body fat percentage by bioelectrical impedance analysis. We studied reproducibility using intraclass correlation coefficients (ICC), coefficient variation with the root-means-square method expressed as p…
Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis
2016
International audience; Objective: To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure.Methods: Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intraobserver and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data.Results: Twenty-seven p…
Using the Hemophilia Joint Health Score for assessment of children: Reliability of the Spanish version
2018
Introduction: Numerous measuring instruments for the evaluation of hemophilic arthropathy have been developed. One of the most used systems is the Hemophilia Joint Health Score (HJHS) given its sensitivity to clinical changes appearing in the joints because of recurrent hemarthrosis. Objective: Assessing the interrater reliability, using the Spanish version of the HJHS (version 2.1) in children with hemophilia. Design: Reliability study to assess the interrater reliability of the Spanish version of HJHS. Methods: A sample of 36 children aged 7–13 years diagnosed with hemophilia A or B was used. Two physiotherapists performed physical assessments with the Spanish version of the HJHS. Descrip…
Genetic analysis of reaction time variability: room for improvement?
2013
Background. Increased reaction time variability (RTV) on cognitive tasks requiring a speeded response is characteristic of several psychiatric disorders. In attention deficit hyperactivity disorder (ADHD), the association with RT is strong phenotypically and genetically, yet high RTV is not a stable impairment but shows ADHD-sensitive improvement under certain conditions, such as those with rewards. The state regulation theory proposed that the RTV difference score, which captures change from baseline to a rewarded or fast condition, specifically measures ‘state regulation’. By contrast, the interpretation of RTV baseline (slow, unrewarded) scores is debated. We aimed to investigate directl…
Construct validity and reliability of the Finnish version of the Knee Injury and Osteoarthritis Outcome Score
2018
Background The Knee Injury and Osteoarthritis Outcome Score (KOOS) is a commonly used knee assessment and outcome tool in both clinical work and research. However, it has not been formally translated and validated in Finnish. The purpose of this study was to translate and culturally adapt the KOOS questionnaire into Finnish and to determine its validity and reliability among Finnish middle-aged patients with knee injuries. Methods KOOS was translated and culturally adapted from English into Finnish. Subsequently, 59 patients with knee injuries completed the Finnish version of KOOS, Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short-Form 36 Health Survey (SF-36) and Numeric Pai…