Search results for "repeatability"
showing 10 items of 214 documents
OCT applications in contact lens fitting
2022
Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essenti…
An environmentally friendly multicommutated alternative to the reference method for anionic surfactant determination in water
2004
Abstract It has been developed a fully mechanized procedure for the spectrophotometric determination of anionic surfactants in water expressed in terms of SDS concentration. The reference method, based on the reaction of SDS with methylene blue (MB) followed by extraction in chloroform, was mechanized in order to reduce the consumption of organic solvents. The system was based on the multicommutation approach and provided a 35 times reduction of the waste production without sacrificing the figures of merit of the method in terms of sensitivity and repeatability, for a dynamic linear range from 0.2 to 1.7 mg l−1. Results obtained for washing water samples were comparable with those obtained …
Introducing a new and rapid microextraction approach based on magnetic ionic liquids: Stir bar dispersive liquid microextraction
2017
With the aim of contributing to the development and improvement of microextraction techniques, a novel approach combining the principles and advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) is presented. This new approach, termed stir bar dispersive liquid microextraction (SBDLME), involves the addition of a magnetic ionic liquid (MIL) and a neodymium-core magnetic stir bar into the sample allowing the MIL coat the stir bar due to physical forces (i.e., magnetism). As long as the stirring rate is maintained at low speed, the MIL resists rotational (centrifugal) forces and remains on the stir bar surface in a manner closely resembling SBS…
Multimycotoxin LC-MS/MS Analysis in Tea Beverages after Dispersive Liquid-Liquid Microextraction (DLLME).
2017
The aim of the present study was to develop a multimycotoxin liquid chromatography tandem mass spectrometry (LC-MS/MS) method with a dispersive liquid-liquid microextraction procedure (DLLME) for the analysis of AFs, 3aDON, 15aDON, NIV, HT-2, T-2, ZEA, OTA, ENNs, and BEA in tea beverages and to evaluate their mycotoxin contents. The proposed method was characterized in terms of linearity, limits of detection (LODs), limits of quantification (LOQs), recoveries, repeatability (intraday precision), reproducibility (interday precision), and matrix effects to check suitability. The results show LODs in the range of 0.05-10 μg/L, LOQs in the range of 0.2-33 μg/L, and recoveries in the range of 65…
Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system
2014
Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…
Reproducibility of pulse wave velocity and augmentation index derived from non-invasive occlusive oscillometric tonometry analysis in adolescents
2018
The aim of this study was to investigate the short-term reproducibility of aortic pulse wave velocity (PWVao) and augmentation index (AIx%) assessed by the non-invasive oscillometric device. Altogether of 55 (19 boys, 36 girls) adolescents 16-19-years-of-age participated in the study. PWVao and AIx% were measured during the same laboratory visit at 2 min intervals using the Arteriograph™ device. Peak oxygen uptake (VO2peak ) was assessed by the maximal exercise test on a cycle ergometer and body fat percentage by bioelectrical impedance analysis. We studied reproducibility using intraclass correlation coefficients (ICC), coefficient variation with the root-means-square method expressed as p…
Multi-analyte method for the analysis of legacy and alternative brominated and chlorinated flame retardants in food products of animal origin using g…
2019
Abstract An analytical method was developed and validated for the analysis of 32 halogenated flame retardants (HFRs), including 13 polybrominated diphenyl ethers (PBDEs), 9 dechlorane-related compounds (DRCs) and 10 of the so-called alternative BFRs in food samples of animal origin. Gas chromatography (GC) coupled with magnetic sector high resolution mass spectrometry (HRMS) was used for the instrumental analysis. Intralaboratory validation of the developed method was performed in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ). Where possible, trueness was verified by the analysis of reference materials (RMs). Fo…
Rationally designed haptens for highly sensitive monoclonal antibody-based immunoanalysis of fenhexamid.
2018
Immunochemical methods have been consolidated during the last few years as complementary analytical strategies for chemical contaminant and residue determination. However, generation of suitable immunoreagents for small organic molecules demands adequate hapten design. In this study, fenhexamid was considered as a model compound and novel haptens were designed and synthesized in order to evaluate the influence of the linker tethering site on antibody binding properties and immunoassay parameters. Haptens were conceived with the spacer arm at different positions, while the more antigenic aromatic moiety was kept free. The synthesis of these functionalized compounds was accomplished by total …
Protein mapping by two-dimensional high performance liquid chromatography.
2000
Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We …
Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics.
2007
The following particulate and monolithic silica columns were implemented in a fully automated and flexible multidimensional LC/MS system with integrated sample clean-up, to perform the analysis of endogeneous peptides from filtered urine and plasma samples: restricted access sulphonic acid strong cation-exchanger (RAM-SCX) for sample clean-up, RP 18 Chromolith guard columns as trap columns and 100 microm I.D. monolithic RP 18 fused silica capillary columns as last LC dimension. The results show sufficient overall system reproducibility and repeatability. Implementation of monolithic silica columns added an additional flexibility with respect to flow rate variation and adjustment due to the …