Analysis of bond strength between a nylon reinforcement structure and dental resins
2021
Made available in DSpace on 2021-06-25T10:30:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-05-01 Background: Nylon is a polymer that its use to reinforce dental resins has shown positive results such as increased flexural strength. The aim of this study was to evaluate the bond strength between dental resins and a nylon reinforcement. Material and Methods: Forty cylindrical nylon blocks with 13 x 23 mm with 0.5% by volume of silica and 40 without were made. Half of the samples of each nylon composition were sandblasted with aluminum oxide (50µm) for 3 s (2.8 bar pressure, distance: 20 mm, incidence angle: 90o). On the nylon blocks, cylinders of chemically activated acrylic resin…
Influence of different parameters on drug release from hydrogel systems to a biomembrane model. Evaluation by differential scanning calorimetry techn…
2000
A comparative study on the drug release capacity of four water swellable polymeric systems was carried out by differential scanning calorimetry (DSC). The polymeric systems chosen were alpha,beta-polyaspartahydrazide (PAHy) crosslinked by glutaraldehyde (GLU) (PAHy-GLU) or by ethyleneglycoldiglycidylether (EGDGE), (PAHy-EGDGE), polyvinylalcohol (PVA) crosslinked by glutaraldehyde (PVA-GLU) and alpha,beta-poly(N-hydroxyethyl)-DL-aspartamide (PHEA) by gamma irradiation (PHEA-gamma matrices). The degree of crosslinking for PAHy-GLU, PAHy-EGDGE and PVA-GLU samples was about 0.4 and 0.8. These hydrogels were characterized as free of drugs and were loaded with diflunisal (DFN) (approximately 2.5%…
Fracture toughness of synthesised high-performance epoxies subject to accelerated water aging
2018
Abstract The effects of water uptake on the fracture toughness of epoxy systems with high glass-transition temperatures (Tg above 170 °C) are investigated. Aging conditioning has been conducted in hot water, followed by a desorption conditioning in a room temperature dry-airborne. Water aging determines plasticisation effects and crosslink-density modifications, revealed by reductions of the Tg. It is less known how such modifications influence the material fracture toughness. In this study, Single Edge Notched Bending samples have been tested according to standards, to evaluate the KIC fracture toughness at different stages of water absorption-desorption. The characterisation has been supp…
Effect of media composition on long-term in vitro stability of barium alginate and polyacrylic acid multilayer microcapsules.
2000
For a number of applications stability of microcapsules is a critical factor. Since the maintenance of polyelectrolyte complexes depends considerably on the ion composition we tested the physical properties of barium alginate capsules and searched for conditions to improve stability by a multilayer coating with polyethylenimine (PEI) and polyacrylic acid (PAA). Mechanical stability and diameters were determined in barium alginate capsules and compared with multilayer capsules. Multilayer coating resulted in smaller capsules than barium complexing alone. The difference was more pronounced when CaCl2 was used instead of NaCl during coating. Barium alginate capsules and application of CaCl2 du…
Synthesis and characterisation of ordered arrays of mesoporous carbon nanofibres
2009
A facile and reproducible one-step pathway has been developed for preparing ordered arrays of mesoporous carbon nanostructures within the pores of anodized aluminium oxide (AAO) membranes, through the confined self-assembly of phenol/formaldehyde resol and amphiphilic copolymer templates. The morphology of the mesoporous carbon nanostructures can be controlled by varying the copolymer surfactant, the quantity of the resol–surfactant precursor sol used and the amount of phenol–formaldehyde resol introduced into the resol–surfactant sol. One-dimensional (1-D) carbon nanostructures, such as carbon fibres with a core–shell structure and carbon ribbons with circular mesopores running parallel to…
Bond strength of a new Kevlar fiber-reinforced composite post with semi-interpenetrating polymer network (IPN) matrix
2019
Background This study aimed to evaluate the bond strength and the penetration depth of two adhesive systems to a new experimental semi-IPN fiber post versus a commercial post. Material and Methods Experimental Kevlar fiber (KF) and control everStick®POST (ES) posts (n=20/ group) with a diameter of 1.5 mm were used, 10 posts coated with StickResin (SR) and the other 10 posts coated with Scotch bond multipurpose (SBMP) adhesives. Composite resin buildup was performed over each post, using a cylindrical plastic mold (10 mm × 6 mm). Four discs of 2 mm thickness were prepared from each post/composite buildup and underwent pushout bond strength test at a crosshead speed of 0.5 mm/min accompanied …
Could sonic delivery of bulk-fill resins improve the bond strength and cure depth in extended size class I cavities?
2020
Background The implementation of restorative procedures that guarantee success and optimize clinical time is the target of investigations in Restorative Dentistry. This study aimed to analyze the influence of sonic insertion of bulk-fill (BF) and conventional (C) resin composites on the microtensile bond-strength (µ-TBS) and cure depth (CD) of large and deep class I restorations. Material and Methods Fifty-six healthy human premolars were selected and occlusal cavities (4 x 4 x 3 mm; factor C = 5) were prepared. TC - Tetric N-Ceram (BF), SF - SonicFill (BF), and Z350 - Filtek Z350 XT (C) composite resins were used to restore the cavities, using sonic (S) and non-sonic (NS) insertion techniq…
Effect of different adhesive strategies on the microtensile bond strength of dentin to indirect resin-based composite.
2020
Background To evaluate the microtensile bond strength of indirect resin composite bonded to dentin using five different adhesives strategies. Material and Methods Forty specimens (Solidex) were produced and randomly into five groups with different adhesives strategies: (G1)- Single Bond Universal + etch + silane + RelyX Ultimate, (G2)- Single Bond Universal + silane + RelyX Ultimate, (G3)- Single Bond Universal + etch + RelyX Ultimate, (G4)- Single Bond Universal + RelyX Ultimate, and (G5)-Scotchbond Multi-purpose + RelyX ARC. After cementation the specimens were stored in 100% humidity for 24hours at 37°C. The specimens were sectioned perpendicular to the adhesive interface to obtain beams…
Elastic wave propagation in bone in vivo: methodology.
1995
The purpose of this study was to investigate the usefulness of elastic wave propagation (EWP) in estimating the mechanical properties (elasticity) of human tibia. The test group was composed of 78-yr-old women assigned to high (n = 19) and low (n = 17) bone mineral density (BMD) groups as measured at the calcaneus by the 125I-photon absorption method. The EWP apparatus consisted of an impact-producing hammer with a force strain gauge and two accelerometers positioned on the bone. Results for nylon and acrylic were used to calibrate the apparatus. Polyvinyl chloride (PVC) solid rods and tubes of various diameters were used to evaluate the relationship between the elastic wave velocity and cr…
Electromagnetic shielding efficiency in Ka-band: carbon foam versus epoxy/carbon nanotube composites
2012
The wide application of microwaves stimulates searching for new materials with high electrical conductivity and electromagnetic (EM) interference shielding effectiveness (SE). We conducted a comparative study of EM SE in K a -band demonstrated by ultra-light micro-structural porous carbon solids (carbon foams) of different bulk densities, 0.042 to 0.150 g/cm 3 , and conventional flexible epoxy resin filled with carbon nanotubes (CNTs) in small concentrations, 1.5 wt.%. Microwave probing of carbon foams showed that the transmission through a 2 mm-thick layer strongly decreases with decreasing the pore size up to the level of 0.6%, due to a rise of reflectance ability. At the same time, 1 mm…