Search results for "resolution."

showing 10 items of 1825 documents

Apparent content curves: description and analytical applications. Resolution of binary mixtures

1992

The apparent content curves and their analytical applications are described. Basing on these curves a mathematical method, which permits the identification of the interfering component present in a binary mixture as well as the determination of the contents of both constituents, is proposed. The existence of considerable interaction coefficients is not an impediment for its application. Besides, the analyte contents in the mixture can be obtained without the use of standard interference solutions. The proposed procedure is applied to the analysis of mixtures of dyes with overlapping absorption spectra.

AnalyteAbsorption spectroscopyResolution (mass spectrometry)ChemistryComponent (thermodynamics)Content (measure theory)Analytical chemistryBinary numberInterference (wave propagation)Biological systemBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Optimisation of gradient elution with serially-coupled columns. Part I: single linear gradients.

2014

A mixture of compounds often cannot be resolved with a single chromatographic column, but the analysis can be successful using columns of different nature, serially combined through zero-dead volume junctions. In previous work (JCA 1281 (2013) 94), we developed an isocratic approach that optimised simultaneously the mobile phase composition, stationary phase nature and column length. In this work, we take the challenge of implementing optimal linear gradients for serial columns to decrease the analysis time for compounds covering a wide polarity range. For this purpose, five ACE columns of different selectivity (three C18 columns of different characteristics, a cyano and a phenyl column) we…

AnalyteChromatographySulfonamidesChromatographyAcetonitrilesResolution (mass spectrometry)LogarithmChemistryOrganic solventOrganic ChemistryAnalytical chemistryReproducibility of ResultsWaterGeneral MedicineModels TheoreticalBiochemistryAnalytical ChemistryColumn (typography)Gradient elutionRetention timeCyano columnAlgorithmsJournal of chromatography. A
researchProduct

Optimisation of chromatographic resolution using objective functions including both time and spectral information.

2014

The optimisation of the resolution in high-performance liquid chromatography is traditionally performed attending only to the time information. However, even in the optimal conditions, some peak pairs may remain unresolved. Such incomplete resolution can be still accomplished by deconvolution, which can be carried out with more guarantees of success by including spectral information. In this work, two-way chromatographic objective functions (COFs) that incorporate both time and spectral information were tested, based on the peak purity (analyte peak fraction free of overlapping) and the multivariate selectivity (figure of merit derived from the net analyte signal) concepts. These COFs are s…

AnalyteMultivariate statisticsChromatographyChromatographyAcetonitrilesTime FactorsResolution (mass spectrometry)ChemistryOrganic ChemistryOrthographic projectionWaterGeneral MedicineBiochemistrySignalChemistry Techniques AnalyticalAnalytical ChemistryPhenolsAlternating least squaresFigure of meritDeconvolutionJournal of chromatography. A
researchProduct

Target analysis and retrospective screening of mycotoxins and pharmacologically active substances in milk using an ultra-high-performance liquid chro…

2020

Milk is a nutritious food suitable for infants and adults, and it plays an important role in the human diet. However, it may also be a vehicle for food contaminants. In this report, we developed a method using ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-Q-Exactive Orbitrap HRMS; Thermo Fisher Scientific, Waltham, MA) for simultaneous identification of target pharmacologically active substances and mycotoxins in milk. We also used the Q-Orbitrap operating in full scan mode to identify other possible drugs and microbial metabolites that occurred in samples. Fifty-six commercially available milk samples from the Italian market were analyze…

AnalyteQuEChERSTarget analysisFood ContaminationOrbitrapMass spectrometryQuechersretrospective analysiMass Spectrometrylaw.inventionmycotoxin03 medical and health scienceschemistry.chemical_compoundlawGeneticsAnimalsMycotoxinChromatography High Pressure Liquid030304 developmental biologyRetrospective Studies0303 health sciencesChromatographyultra-high-performance liquid chromatography/high-resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS)pharmacologically active substanceChemistry0402 animal and dairy science04 agricultural and veterinary sciencesContaminationMycotoxins040201 dairy & animal scienceMilkItalyAnimal Science and ZoologyFood ScienceFood contaminantJournal of dairy science
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

Comparison between micellar liquid chromatography and capillary zone electrophoresis for the determination of hydrophobic basic drugs in pharmaceutic…

2007

[EN] The determination of highly hydrophobic basic compounds by means of conventional reversed-phase liquid chromatographic methods has several drawbacks. Owing to the characteristics of micellar liquid chromatography (MLC) and capillary electrophoresis (CE), these techniques could be advantageous alternatives to reversed-phase chromatographic methods for the determination of these kinds of compounds. The objective of this study was to develop and compare MLC and CE methods for the determination of antipsychotic basic drugs (amitryptiline, haloperidol, perphenazine and thioridazine) in pharmaceutical preparations. The chromatographic determination of the analytes was performed on a Kromasil…

AnalyteResolution (mass spectrometry)Capillary actionClinical BiochemistrySensitivity and SpecificityBiochemistryAnalytical ChemistryCapillary electrophoresischemistry.chemical_compoundCapillary electrophoresisBromideDrug DiscoveryQUIMICA ANALITICAAntipsychotic drugsMolecular BiologyPharmacologyDetection limitChromatographyElectrophoresis CapillaryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationReference StandardsElectrophoresisPharmaceutical PreparationschemistryHydrophobic basic drugsMicellar liquid chromatographyCalibrationPharmaceutical analysisHydrophobic and Hydrophilic InteractionsCetyltrimethylammonium bromideMicellar liquid chromatographyAntipsychotic AgentsChromatography Liquid
researchProduct

Multivariate optimization approach for chiral resolution of drugs using human serum albumin in affinity electrokinetic chromatography-partial filling…

2005

The enantiomeric resolution of chiral compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer, protein and compound solutions) and protein solution plug length. In this paper multivariate optimization approaches for chiral separation of four basic drugs (alprenolol, oxprenolol, promethazine and propranolol) using HSA as chiral selector in AEKC-partial filling technique are studied. The experimental conditions to achieve maximum resolution are optimized using the Box-Behnken experimental design. Partial least squares a…

AnalyteResolution (mass spectrometry)Clinical BiochemistryAnalytical chemistryBiochemistryPromethazineChromatography AffinityAnalytical ChemistryElectrokinetic phenomenaPartial least squares regressionmedicineHumansAminesAlprenololSerum AlbuminChromatographyChemistryElectrophoresis CapillaryOxprenololStereoisomerismHuman serum albuminPropranololChiral resolutionElectrophoresisPharmaceutical PreparationsMultivariate AnalysisEnantiomerHydrophobic and Hydrophilic Interactionsmedicine.drugElectrophoresis
researchProduct

Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.

2002

This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…

AnalyteResolution (mass spectrometry)medicine.drug_classBiophysicsBiochemistrySensitivity and Specificitychemistry.chemical_compoundIsomerismmedicineHumansEphedrineDerivatizationAmphetamineChromatography High Pressure LiquidChromatographyStaining and LabelingIllicit DrugsAmphetaminesDiastereomerReproducibility of ResultsDesigner drugSubstance Abuse DetectionchemistryModels ChemicalEnantiomermedicine.drugChromatography LiquidJournal of biochemical and biophysical methods
researchProduct

Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations

1998

The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…

Analytegenetic structuresResolution (mass spectrometry)ChemistrySample (material)Analytical chemistryPhysics::OpticsBiochemistrySpectral lineAnalytical ChemistryChemometricsAbsorbanceWavelengthStandard additionElectrochemistryEnvironmental Chemistrysense organsSpectroscopyThe Analyst
researchProduct

Stimulated Raman and Cars Spectroscopy of ν1 and 2ν2 (A1) Bands of 12CF4

1994

Two experimental coherent Raman techniques, stimulated Raman and coherent anti-Stokes Raman spectroscopy (CARS), were employed to study the Raman spectrum of CF 4 in the 900 cm −1 region. The stimulated Raman and CARS spectra of the ν 1 band of CF 4 were recorded at high resolution. The analysis of these spectra enabled some spectroscopic constants of this band to be refined and higher order constants to be determined for the first time. The first high-resolution CARS spectrum of the 2ν 2 (A 1 ) harmonic band is also presented. The rotational transitions of this band up to J = 40 were assigned and the first set of spectroscopic constants for this sub-level were determined. These results imp…

Analytical chemistryHigh resolutionCF4 LASER02 engineering and technology01 natural sciencesQ-BRANCHSpectral lineREGIONABSORPTION-SPECTROSCOPYsymbols.namesake0103 physical sciencesVibrational bandsSPECTRAGeneral Materials ScienceStimulated ramanCoherent anti-Stokes Raman spectroscopyStimulated emissionPOTENTIAL FUNCTIONRADIOFREQUENCY DOUBLE-RESONANCESpectroscopySpectroscopy010304 chemical physicsMOLECULAR LASERSChemistry021001 nanoscience & nanotechnologyRESOLUTION INFRARED-SPECTROSCOPYsymbols0210 nano-technologyRaman spectroscopyDOUBLE-RESONANCE SPECTROSCOPY
researchProduct