Search results for "resolution"
showing 10 items of 1928 documents
Image enhancement in photoemission electron microscopy by means of imaging time-of-flight analysis
2004
Abstract Photoemission electron microscopy (PEEM) is widely used in combination with synchrotron sources as a powerful tool to observe chemical and magnetic properties of metal and semiconductor surfaces. Presently, the resolution limit of these instruments using soft-X-ray excitation is limited to about 50 nm, because of the chromatic aberation of the electron optics used. Various sophisticated approaches have thus been reported for enhancing the spatial resolution in photoemission electron microscopy. This work demonstrates the use of a simple imaging energy filter based on electron time-of-flight (ToF) selection. The spatial resolution could be improved dramatically, even though the inst…
NanoESCA: imaging UPS and XPS with high energy resolution
2005
Abstract A novel imaging electron spectrometer has been used for laterally resolved ultraviolet photoelectron spectroscopy (UPS) and X-ray photoelectron spectroscopy (XPS) in the soft X-ray range. The instrument is based on a high-resolution emission microscope optics using a cathode lens and an imaging dispersive analyser. The analyser is corrected for the leading aberration term ( α 2 -term) by means of two hemispherical analysers in antisymmetric configuration with an appropriate transfer lens. Small-area spectra as well as energy-filtered images have been taken in the soft X-ray range for a meteorite sample and in the range of the d-band of a Cu polycrystal. An energy resolution of 106 …
Fast elemental mapping and magnetic imaging with high lateral resolution using a novel photoemission microscope
1998
Abstract Using tunable soft X-ray synchrotron radiation and a new-generation photoemission electron microscope with integral sample stage and microarea selector, elemental images and local XANES spectra have been measured. Given the present conditions (PM3 at BESSY), the lateral resolution was in the range of 130 nm with the potential of considerable improvement with high-brilliance sources (a base resolution of 25 nm was obtained in threshold photoemission). Measurements at the oxygen K-edge demonstrate that differences in the local chemical environment of the emitter atom are clearly revealed and can thus be used as a fingerprint technique for its chemical state and geometrical surroundin…
Multipole WIEN-filter for a high-resolution X-PEEM
1997
Abstract The development and construction of an X-PEEM with integral multipole WIEN-filter for spectromicroscopy with high lateral resolution is presented. All relevant electron-optical properties of the filter have been examined by field and trajectory calculations. Electric and magnetic multipole components (dipole, quadrupole and hexapole) can be chosen independently from each other, thus allowing electron-optical corrections. Theoretical values for the lateral resolution are in the range of 10 nm, experimental values of ≤25 nm have been achieved using the column without filter. The instrument is designed in particular for the use of Sychrotron radiation as well as new, high-brilliance l…
Spherical top data system (STDS) software for the simulation of spherical top spectra
1998
Abstract The Spherical Top Data System (STDS) software package for the simulation of spherical top spectra is presented. It consists of a single UNIX script with self-explanatory arguments allowing the non-expert user to calculate spectra from the results of the high resolution analyses performed over the recent decades on this type of molecules. More than one hundred parameter files are presently available including various band systems of 16 molecular species (among which methane is the most documented) and various types of calculations: rovibrational energy levels, i.r. absorption, Raman scattering and Stark coefficients. STDS is freely accessible by anonymous ftp at jupiter.u-bourgogne.…
Jet collimation in NGC 315 and other nearby AGN
2020
Aims. The collimation of relativistic jets in galaxies is a poorly understood process. Detailed radio studies of the jet collimation region have been performed so far in few individual objects, providing important constraints for jet formation models. However, the extent of the collimation zone as well as the nature of the external medium possibly confining the jet are still debated. Methods. In this article we present a multi-frequency and multi-scale analysis of the radio galaxy NGC 315, including the use of mm-VLBI data up to 86 GHz, aimed at revealing the evolution of the jet collimation profile. We then consider results from the literature to compare the jet expansion profile in a samp…
The nature of radiohaloes in biotite: Experimental studies and modeling
2001
Several micro-techniques (confocal laser-Raman microprobe, optical absorption micro-spectroscopy, high-resolution transmission electron microscopy, electron microprobe analysis) were employed in the detailed characterization of radiohaloes in biotites from two Variscan rocks from Germany. The studied biotites are intermediate members of the phlogopite-annite series with Mg/Fe 2+ ratios in the range 1.6–1.0. Radiohaloes in biotite resulted from the impact of 4 He cores (α-particles) emitted from actinide-bearing inclusions. Monte Carlo simulations yielded α ( 238 U, 235 U, and 232 Th series) penetration ranges in biotite between 12.5 and 37.3 μm, which are in reasonable agreement with the ob…
Digital CZT detector system for high flux energy-resolved X-ray imaging
2017
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…
Test of the MODIS Land Surface Temperature and Emissivity Separation Algorithm With Ground Measurements Over a Rice Paddy
2016
The Moderate Resolution Imaging Spectroradiometer (MODIS) land surface temperature (LST) and emissivity separation (MODTES) algorithm is the basis of the MOD21 product, which provides 1-km LSTs and emissivities for bands 29 (8.55 μm), 31 (11 μm), and 32 (12 μm). The MODTES algorithm uses the TES method with the water vapor scaling (WVS) method for refined atmospheric correction. The performance of the MODTES algorithm was tested with a set of MODIS data concurrent with ground LST and emissivity measurements. The test site is a large area of homogeneous full-cover rice crops (graybody), with high atmospheric water vapor. The data included LSTs measured along transects with multiple calibrate…
Impact of Spectral Resolution on Quantifying Cyanobacteria in Lakes and Reservoirs: A Machine-Learning Assessment
2022
Cyanobacterial harmful algal blooms are an increasing threat to coastal and inland waters. These blooms can be detected using optical radiometers due to the presence of phycocyanin (PC) pigments. The spectral resolution of best-available multispectral sensors limits their ability to diagnostically detect PC in the presence of other photosynthetic pigments. To assess the role of spectral resolution in the determination of PC, a large (N = 905) database of colocated in situ radiometric spectra and PC are employed. We first examine the performance of selected widely used machine-learning (ML) models against that of benchmark algorithms for hyperspectral remote sensing reflectance ( $R_{{rs}})$…