Search results for "sensi"
showing 10 items of 5553 documents
Enhanced field-of-view integral imaging display using multi-Köhler illumination.
2014
A common drawback in 3D integral imaging displays is the appearance of pseudoimages beyond the viewing angle. These pseudoimages appear when the light rays coming from each elemental image are not passing through the corresponding microlens, and a set of barriers must be used to avoid this flipping effect. We present a pure optical arrangement based on Köhler illumination to generate these barriers thus avoiding the pseudoimages. The proposed system does not use additional lenses to project the elemental images, so no optical aberrations are introduced. As an added benefit, Köhler illumination provides a higher contrast 3D display. This work was supported in part by the Plan Nacional I + D …
Synthesis of New 2-{[(Phenoxy or Phenyl)acetyl]amino}benzoic Acid Derivatives as 3α-Hydroxysteroid Dehydrogenase Inhibitors and Potential Antiinflamm…
1995
A number of 2-([(phenoxy or phenyl)acetyl]amino)benzoic acid derivatives were prepared in about 50% yield from (phenoxy or phenyl)acetyl chloride and anthranilic acid derivatives. All the compounds were tested as in vitro inhibitors of 3 alpha-hydroxysteroid dehydrogenase, since enzyme inhibition predicts potential antiinflammatory activity in vivo. The most active compounds 3 l, m, s are about 3.5 times more active than acetylsalicylic acid (ASA). Activity is influenced by electronic as well as steric effects.
Macular sensitivity and structure in idiopathic epiretinal membranes 12 months after surgical treatment
2013
Purpose: To evaluate macular sensitivity (MS) change and its correlation with visual acuity (VA) and Spectral-Domain Optical Coherence Tomography (SD-OCT) in patients with idiopathic epiretinal membrane (ERM) at 3, 6 and 12 months after surgical treatment.Methods: Prospective, monocenter, interventional case series. We included 49 patients (49 eyes) with an idiopathic ERM scheduled for a surgical treatment. Among these patients, 40 were evaluated at 3 and 6 months (M3, M6), and 31 at 12 months (M12) after ERM and internal limiting membrane removal. At each visit a measurement of best-corrected visual acuity (ETDRS), a microperimetry and a SD-OCT were performed for all patients.Results: The …
New tricyclic systems as photosensitizers towards triple negative breast cancer cells.
2022
AbstractNineteen pyrrolo[1,2-h][1,7]naphthyridinones and pyrido[2,3-c]pyrrolo[1,2-a]azepinones were synthesized as new tricyclic systems in which the pyridine ring is annelated to the 6,7-dihydroindolizin-8(5H)-one and 5,6,7,8-tetrahydro-9H-pyrrole[1,2-a]azepine-9-one moieties to obtain potential photosensitizing agents. They were tested for their photoantiproliferative activity on a triple-negative breast cancer cell line, MDA-MB-231, in the dark and under UVA light (2.0 J/cm2). We demonstrated that their toxicity, only when exposed to light, was primarily due to the generation of reactive oxygen species while their photodegradation products were not responsible for their activity. The mos…
Marcadores citogenéticos aplicados en biomedicina = Cytogentic biomarkers applied in biomedicine
2013
Cuando se pretende identificar una determinada exposición a una sustancia exógena al organismo se utilizan biomarcadores que nos permitan confirmar esta exposición. En el caso de que la exposición provoque un efecto nocivo en el material genético, el interés se centra en biomarcadores genotóxicos. Si el efecto en el material genético se traduce en cambios en la estructura o en el número de cromosomas observables y cuantificables mediante técnicas citogenéticas, estos cambios se podrán emplear como biomarcadores citogenéticos. De hecho, los biomarcadores citogenéticos son criterios de valoración frecuentemente utilizados en estudios poblacionales. Su sensibilidad para la medición de exposici…
An FPGA aligner for short read mapping
2012
The rapid growth of short read datasets poses a new challenge to the mapping of short reads to a reference genome in terms of sensitivity and execution speed. In this work, we present a parallel architecture for short read mapping utilizing field programmable gate array (FPGA)-based hardware. The computation intensive semi-global alignment and the hash table lookup operations are mapped onto an FPGA. The proposed Align Core is implemented with a parallel block structure to gain computational efficiency. We present a new parallel block-wise alignment structure to approximate the conventional dynamic programming algorithm. The performance of our FPGA aligner is compared to the GASSST and BWA …
A hybrid short read mapping accelerator
2013
Background The rapid growth of short read datasets poses a new challenge to the short read mapping problem in terms of sensitivity and execution speed. Existing methods often use a restrictive error model for computing the alignments to improve speed, whereas more flexible error models are generally too slow for large-scale applications. A number of short read mapping software tools have been proposed. However, designs based on hardware are relatively rare. Field programmable gate arrays (FPGAs) have been successfully used in a number of specific application areas, such as the DSP and communications domains due to their outstanding parallel data processing capabilities, making them a compet…
Pain Neuroscience Education and Physical Therapeutic Exercise for Patients with Chronic Spinal Pain in Spanish Physiotherapy Primary Care: A Pragmati…
2020
Producción Científica
Probing the Effects of Strong Electromagnetic Fields with Charge-Dependent Directed Flow in Pb-Pb Collisions at the LHC
2020
The first measurement at the LHC of charge-dependent directed flow ($v_{1}$) relative to the spectator plane is presented for Pb-Pb collisions at $\sqrt{s_{\rm NN}}$ = 5.02 TeV. Results are reported for charged hadrons and $\rm D^{0}$ mesons for the transverse momentum intervals $p_{\rm T}>0.2$ GeV/$c$ and $3<p_{\rm T}<$ 6 GeV/$c$ in the 5-40% and 10-40% centrality classes, respectively. The difference between the positively and negatively charged hadron $v_{1}$ has a positive slope as a function of pseudorapidity $\eta$, ${\rm d}\Delta{v_1}/{\rm d}\eta=$[1.68 $\pm$ 0.49 (stat.) $\pm$ 0.41 (syst.)] $\times 10^{-4}$. The same measurement for $\rm D^{0}$ and $\rm\bar{D}{}^0$ mesons yields a p…
Integrating Physics Modelling with Machine Learning for Remote Sensing
2020
L’observació de la Terra a partir de les dades proporcionades per sensors abord de satèl·lits, així com les proporcionades per models de transferència radiativa o climàtics, juntament amb les mesures in situ proporcionen una manera sense precedents de monitorar el nostre planeta amb millors resolucions espacials i temporals. La riquesa, quantitat i diversitat de les dades adquirides i posades a disposició també augmenta molt ràpidament. Aquestes dades ens permeten predir el rendiment dels cultius, fer un seguiment del canvi d’ús del sòl com ara la desforestació, supervisar i respondre als desastres naturals, i predir i mitigar el canvi climàtic. Per tal de fer front a tots aquests reptes, l…