Evaluation of gastric intramucosal pH during and after pediatric cardiac surgery.

1997

Objectives: In adult patients, intramucosal pH (pHi) has been advocated to detect postoperative complications. The purpose of our study was to evaluate this technique in pediatric patients during and after cardiac surgery. Methods: Thirty-five infants (age: 5 days to 15 years, median 1.8 years; and weight: 3.2‐32 kg, median 9.8 kg) were studied. pHi was measured before cardiopulmonary bypass (CPB), after 30 min of CPB, prior to weaning off CPB, at intensive care unit arrival, and 6, 12, 24, 48 and 72 h after surgery. Results: There were no complications related to the tonometer. A pathologically low pHiB 7.32 was found during surgery in less than 17%, at intensive care unit arrival in 83% a…

Pulmonary and Respiratory MedicineHeart Defects CongenitalMalemedicine.medical_specialtyAdolescentmedicine.medical_treatmentSensitivity and Specificitylaw.inventionFontan procedurePostoperative ComplicationslawIntensive Care Units NeonatalMonitoring IntraoperativemedicineCardiopulmonary bypassHumansChildSurvival ratebusiness.industryStomachOrgan dysfunctionCentral venous pressureInfant NewbornInfantGeneral MedicineHydrogen-Ion ConcentrationIntensive care unitSurgeryCardiac surgerySurvival Ratemedicine.anatomical_structureGastric MucosaAnesthesiaChild PreschoolSurgeryFemalemedicine.symptomMorbidityCardiology and Cardiovascular MedicinebusinessEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
researchProduct

Patterns and diagnostic value of cardiac troponin I vs. troponin T and CKMB after OPCAB surgery.

2001

Cardiac troponin I (cTnI) has been shown to be a specific marker for myocardial injury in cardiac surgery. The object of this prospective study was to determine the patterns and kinetic and diagnostic value of cTnI, cardiac troponin T (cTnT), and creatine kinase MB (CKMB) activity after minimally invasive coronary revascularization using an octopus device on the beating heart (OPCAB).48 patients (33 male/15 female, mean age 68.3 +/- 8.7 years) underwent their first elective OPCAB surgery with median sternotomy without mortality. The mean number of grafts was 2.0 +/- 0.8 per patient. Preoperative mean ejection fraction was 56.6 % +/- 14.9%. CTnI and T levels, total creatine kinase (CK) and C…

Pulmonary and Respiratory MedicineMalemedicine.medical_specialtyMyocardial Infarctionmacromolecular substancesSensitivity and SpecificityElectrocardiographyTroponin complexTroponin TInternal medicineTroponin ImedicineMyocardial RevascularizationCreatine Kinase MB FormHumanscardiovascular diseasesProspective StudiesRadionuclide ImagingCreatine KinaseVascular PatencyAgedEjection fractionbiologyTroponin Tbusiness.industryTroponin IPerioperativeMiddle Agedmusculoskeletal systemMagnetic Resonance ImagingCardiac surgerySurgeryIsoenzymesROC Curvecardiovascular systemCardiologybiology.proteinSurgeryCreatine kinaseFemaleMyocardial infarction diagnosisCardiology and Cardiovascular MedicinebusinessBiomarkersThe Thoracic and cardiovascular surgeon
researchProduct

Potential of non-invasive breath tests for preselecting individuals for invasive gastric cancer screening endoscopy.

2018

Background. Regular screening for gastric cancer (GC) is based on invasive upper gastrointestinal endoscopy and is limited to few high-incidence countries. As GC is a major cause of cancer death worldwide, a non-invasive, simple screening test is of value. We assessed the prevalence of preclinical GC and the corresponding numbers needed to screen (NNS) to detect GC cases both without and with preselection using breath tests from the literature in various populations. Methods. Using age- and sex-specific GC incidence data and rates of transition from preclinical to clinical GC, we estimated the prevalences of preclinical GC worldwide in populations aged 50–74 years, and we evaluated the accu…

Pulmonary and Respiratory MedicineMalemedicine.medical_specialtySensitivity and Specificity03 medical and health sciences0302 clinical medicinePredictive Value of TestsStomach NeoplasmsInternal medicineIncidence datamedicinePrevalenceHumansEarly Detection of CancerAgedBreath testmedicine.diagnostic_testbusiness.industrydigestive oral and skin physiologyNon invasiveCancerEndoscopyMiddle Agedmedicine.diseasePredictive valueUpper gastrointestinal endoscopyEndoscopyBreath Tests030220 oncology & carcinogenesisGastric cancer screening030211 gastroenterology & hepatologyFemalebusinessJournal of breath research
researchProduct

Postoperative non-invasive assessment of pulmonary vascular resistance using Doppler echocardiography.

2011

Non-invasive monitoring of pulmonary vascular resistance (PVR) in postoperative cardiac surgery patients might be useful, particularly for management of pulmonary hypertension. For this purpose, we sought to assess Doppler echocardiography in the intensive care setting. In 73 patients, hemodynamics was measured using both, invasive gold standard (pulmonary artery catheter), and non-invasively by Doppler echocardiography. Four Doppler parameters: (1) tricuspid regurgitant velocity/time-velocity-integral of right ventricular outflow tract (TRV/VTI(RVOT)), (2) tricuspid annular systolic velocity (S'), (3) tricuspid annular strain, and (4) tricuspid annular strain rate, were compared with invas…

Pulmonary and Respiratory Medicinemedicine.medical_specialtymedicine.medical_treatmentHypertension PulmonaryBlood PressureDoppler echocardiographyPulmonary ArterySensitivity and SpecificityVentricular Function LeftPredictive Value of TestsInternal medicineIntensive careGermanymedicineVentricular outflow tractHumansFamilial Primary Pulmonary Hypertensioncardiovascular diseasesSystoleCardiac Surgical ProceduresPulmonary wedge pressureAgedAged 80 and overPostoperative CareChi-Square Distributionmedicine.diagnostic_testbusiness.industryPulmonary artery catheterMiddle Agedmedicine.diseasePulmonary hypertensionEchocardiography DopplerIntensive Care Unitsmedicine.anatomical_structureCatheterization Swan-Ganzcardiovascular systemVascular resistanceCardiologyLinear ModelsVentricular Function RightSurgeryVascular ResistanceTricuspid ValveCardiology and Cardiovascular MedicinebusinessInteractive cardiovascular and thoracic surgery
researchProduct

Assessment of a Modified Acoustic Lens for Electromagnetic Shock Wave Lithotripters in a Swine Model

2013

The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model.Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave trea…

Pulse repetition frequencyShock wavemedicine.medical_specialtySwineUrologySus scrofaMicroscopy AcousticSensitivity and SpecificityArticlelaw.inventionFocal zoneKidney CalculiElectromagnetic FieldsPressure waveformlawLithotripsymedicineAnimalsPulse energyEquipment Safetybusiness.industryEquipment DesignAcoustic lensSurgeryLens (optics)Disease Models AnimalShock wave lithotripterFemalebusinessBiomedical engineering
researchProduct

Determination of ultratrace bismuth in milk samples by atomic fluorescence spectrometry.

2003

Abstract A sensitive procedure was developed for determination of bismuth (Bi) in milk samples by hydride generation atomic fluorescence spectrometry (HG–AFS) after microwave-assisted sample digestion with HNO3 and H2O2. The method provides a sensitivity of 1832 fluorescence units (ng/mL) with a detection limit of 0.01 ng/mL, which corresponds to 20 pg absolute limit of detection, equivalent to 0.50 ng/g in the original sample. Application of the methodology to cow milk samples from the Spanish market showed the presence of Bi at a concentration of 11.8–28.8 ng/g, which compared well with data obtained after dry ashing of samples and with data obtained by inductively coupled plasma–mass spe…

Quality ControlAnalytical chemistrychemistry.chemical_elementBorohydridesMass spectrometryAtomic fluorescence spectrometrySensitivity and SpecificityFluorescenceAnalytical ChemistryBismuthCow milkDigestion (alchemy)Environmental ChemistryAnimalsArgonMicrowavesPharmacologyDetection limitHydrideSpectrum AnalysisMilkAshingchemistrySpainIndicators and ReagentsAgronomy and Crop ScienceBismuthFood ScienceJournal of AOAC International
researchProduct

Matrix solid-phase dispersion microextraction and determination by high-performance liquid chromatography with UV detection of pesticide residues in …

1999

A multiresidue method based on matrix solid-phase dispersion (MSPD) microextraction was studied to determine the carbamate, benfuracarb, and urea insecticides, diflubenzuron, flufenoxuron hexaflumuron and hexythiazox, used in control of citrus pests. Optimisation of different parameters, such as the type of solid support for matrix dispersion, elution solvents and the clean-up step were carried out. The method used 0.5 g of orange sample, C8 bonded silica as MSPD sorbent and dichloromethane as eluting solvent. Recoveries, at spiked concentrations below the maximum residue levels established by Spanish Government, were between 74 and 84% with relative standard deviations ranging from 2 to 4%…

Quality ControlCarbamateInsecticidesmedicine.medical_treatmentBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistrymedicineSample preparationSolid phase extractionChromatography High Pressure LiquidBenzofuransChromatographyPesticide residueChemistryElutionPhenylurea CompoundsOrganic ChemistryPesticide ResiduesGeneral MedicineReversed-phase chromatographySolventFruitBenzamidesbeta-AlanineIndicators and ReagentsDiflubenzuronJournal of chromatography. A
researchProduct

Pressurized liquid extraction combined with capillary electrophoresis–mass spectrometry as an improved methodology for the determination of sulfonami…

2007

A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitori…

Quality ControlMeatSwineFood ContaminationComplex MixturesMass spectrometryTandem mass spectrometrySensitivity and SpecificityBiochemistryCapillary electrophoresis–mass spectrometryAnalytical ChemistryCapillary electrophoresisTandem Mass SpectrometryPressuremedicineAnimalsSample preparationSulfonamidesChromatographyChemistrySulfadimidineOrganic ChemistrySelected reaction monitoringSulfabenzamideElectrophoresis CapillaryWaterGeneral MedicineCalibrationFood AnalysisChromatography Liquidmedicine.drugJournal of Chromatography A
researchProduct

Absence Ochratoxin A in soy sauce

2004

A method is described for the determination of ochratoxin A (OTA) in soy sauce using phosphate-buffered saline (PBS) extraction, an immunoaffinity clean-up, a liquid chromatographic determination with fluorescence detection (LC-FD) and confirmation with LC-FD after methylation of OTA. Recoveries of OTA spiked to soy sauce samples at 0.25 ng/ml level were 90% with relative standard deviations of 4%. The limit of detection was 0.01 ng/ml for OTA using the proposed method. Furthermore, the proposed method was applied to 60 soy sauce samples from China and Japan and none of them were found to contain OTA.

Quality ControlOchratoxin ADetection limitChromatographyImmunochemistryExtraction (chemistry)Soy FoodsFood ContaminationGeneral MedicineOchratoxinsSensitivity and SpecificityMicrobiologyFluorescencechemistry.chemical_compoundchemistryFood scienceChromatography LiquidFood ScienceInternational Journal of Food Microbiology
researchProduct

SPET/CT image co-registration in the abdomen with a simple and cost-effective tool

2002

Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq (111)In…

Quality ControlRadiography AbdominalRestraint Physicalmedicine.medical_specialtyImage qualityRadiographySingle-photon emission computed tomographyDigestive System NeoplasmsSensitivity and SpecificityAbdomenHumansMedicineRadiology Nuclear Medicine and imagingTomography Emission-Computed Single-PhotonImage fusionmedicine.diagnostic_testbusiness.industryLiver NeoplasmsSubtractionReproducibility of ResultsGeneral MedicineImage EnhancementNeuroendocrine TumorsPositron emission tomographySubtraction TechniqueTomographyRadiologyTomography X-Ray ComputedbusinessNuclear medicineEmission computed tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging
researchProduct