Search results for "single photon"
showing 10 items of 27 documents
Single photon emission from impurity centers in AlGaAs epilayers on Ge and Si substrates
2012
We show that the epitaxial growth of thin layers of AlGaAs on Ge and Si substrates allows to obtain single photon sources by exploiting the sparse and unintentional contamination with acceptors of the AlGaAs. Very bright and sharp single photoluminescence lines are observed in confocal microscopy. These lines behave very much as single excitons in quantum dots, but their implementation is by far much easier, since it does not require 3D nucleation. The photon antibunching is demonstrated by time resolved Hanbury Brown and Twiss measurements.
Roadmap on STIRAP applications
2019
STIRAP (stimulated Raman adiabatic passage) is a powerful laser-based method, usually involving two photons, for efficient and selective transfer of populations between quantum states. A particularly interesting feature is the fact that the coupling between the initial and the final quantum states is via an intermediate state, even though the lifetime of the latter can be much shorter than the interaction time with the laser radiation. Nevertheless, spontaneous emission from the intermediate state is prevented by quantum interference. Maintaining the coherence between the initial and final state throughout the transfer process is crucial. STIRAP was initially developed with applications in …
Two-Color Single-Photon Emission from In As Quantum Dots: Toward Logic Information Management Using Quantum Light
2014
In this work, we propose the use of the Hanbury-Brown and Twiss interferometric technique and a switchable two-color excitation method for evaluating the exciton and noncorrelated electron-hole dynamics associated with single photon emission from indium arsenide (InAs) self-assembled quantum dots (QDs). Using a microstate master equation model we demonstrate that our single QDs are described by nonlinear exciton dynamics. The simultaneous detection of two-color, single photon emission from InAs QDs using these nonlinear dynamics was used to design a NOT AND logic transference function. This computational functionality combines the advantages of working with light/photons input/output device…
Synchronization of optical photons for quantum information processing
2015
We observe the Hong-Ou-Mandel interference via homodyne tomography on two photons extracted from two quantum memories.
Future axion searches with the International Axion Observatory (IAXO)
2013
Çetin, Serkant Ali (Dogus Author) -- Conference full title: 6th Symposium on Large TPCs for Low Energy Rare Event Detection; Paris; France; 17 December 2012 through 19 December 2012. The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of gaγ ∼ few × 10-12 GeV-1, i.e. 1-1.5 orders of magnitude beyond the one achieved by CAST, currently the most sensitive axion helioscope. The main elements of IAXO are an increased magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested in CAST. Additional physics cases of IAXO could include …
Timing Control of a Heralded Single Photon Emission
2012
We experimentally demonstrate controlling the emission timing of a heralded single photon from a non-degenerate optical parametric oscillator, by placing another quickly tunable cavity at the exit as a shutter.
First coincidences in pre-clinical Compton camera prototype for medical imaging
2003
Abstract Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500 μm thick, 256 pad silicon detector with pad size of 1.4×1.4 mm 2 , combined with a 15×15×1 cm 3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (…
Preliminary radiation hardness tests of single photon Si detectors
2010
Single photon Si detectors were fabricated by STMicroelectronics and fully characterized in standard operation conditions and after irradiations. Both single cells and arrays, of dimensions ranging from 5x5 up to 64x64, were electrically tested. The devices operation was studied as a function of the temperature from -25 degrees C to 65 degrees C varying the voltage over breakdown, from 5% up to 20% of the breakdown voltage before and after irradiation using both light ions, 10 MeV B ions to doses in the range 3x10(7)-5x10(10) cm(-2), and X-rays irradiations in the range 0.5-20 krad(Si). Optical characterization was performed using a laser at 659 nm and opportunely chosen filters to vary the…
High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization
2018
The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell…
Intraoperative Scintigraphy With Portable Gamma Camera for the Localization of Interaortocaval Paraganglioma
2021
A 15-year-old adolescent girl diagnosed of interaortocaval paraganglioma with a positive 123I-MIGB SPECT/CT and 1 unsuccessful prior surgery was operated on with the assistance of a handheld gamma camera. Once the lesion was located and removed, 2 images were taken, one of the surgical field (without 123I-MIGB uptake) and another of the tumor ex vivo (with high 123I-MIGB uptake), confirming that the lesion had been satisfactorily excised. This case highlights the use of a portable gamma camera as a useful tool to locate this rare tumor, with a SPECT/CT positive for 123I-MIGB and a difficult anatomical location suspected.