Search results for "solid phase"

showing 10 items of 360 documents

Development and validation of a pressurized liquid extraction liquid chromatography–tandem mass spectrometry method for perfluorinated compounds dete…

2009

Abstract This paper describes the development and validation of an analytical methodology to determine eight perfluorinated compounds (PFCs) in edible fish using pressurized liquid extraction (PLE) with water and solid-phase extraction (SPE) with an ion-exchanger as extraction and pre-concentration procedures, followed by liquid chromatography–quadrupole-linear ion trap mass spectrometry (LC–QqLIT–MS). The rapidity and effectiveness of the proposed extraction procedure were compared with those most commonly used to isolate PFCs from fish (ion-pairing and alkaline digestion). The average recoveries of the different fish samples, spiked with the eight PFCs at three levels (the LOQ, 10 and 100…

Chemical Fractionation010501 environmental sciencesMass spectrometryTandem mass spectrometrySensitivity and Specificity01 natural sciencesBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundTandem Mass SpectrometryLiquid chromatography–mass spectrometryPressureAnimalsSample preparation14. Life underwaterSolid phase extractionMuscle Skeletal0105 earth and related environmental sciencesFluorocarbonsChromatography010401 analytical chemistryOrganic ChemistryExtraction (chemistry)FishesReproducibility of ResultsGeneral Medicine0104 chemical sciencesLiverchemistryLinear ModelsPerfluorooctanoic acidFood AnalysisChromatography LiquidJournal of Chromatography A
researchProduct

Determination of bisphenol diglycidyl ether residues in canned foods by pressurized liquid extraction and liquid chromatography–tandem mass spectrome…

2005

Abstract A new confirmatory method for simultaneous determination of bisphenol diglycidyl ether residues (BADGE, BADGE·H2O, BADGE·2H2O, BADGE·H2O·HCl, BADGE·HCl, BADGE·2HCl, BFDGE and BFDGE·2HCl) from canned food has been developed. The proposed method includes extraction by pressurized liquid extraction (PLE) followed by liquid–liquid partition and purification by solid phase extraction (SPE). Several solvent systems and different operating conditions (time, temperature) have been investigated for PLE optimization. A reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to atmospheric pressure chemical ionisation tandem mass spectrometry (APCI-MS–MS) method was developed …

Chemical ionizationDiglycidyl etherChromatographyBisphenolOrganic ChemistryTemperatureAtmospheric-pressure chemical ionizationGeneral MedicineBiochemistryHigh-performance liquid chromatographyMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundAtmospheric PressurechemistryLiquid chromatography–mass spectrometrySolventsEpoxy CompoundsSolid phase extractionBenzhydryl CompoundsBisphenol A diglycidyl etherChromatography High Pressure LiquidFood AnalysisJournal of Chromatography A
researchProduct

Current trends in affinity-based monoliths in microextraction approaches: A review

2019

Abstract This article reviews the research contributions along the past five years concerning to monolithic materials for the development of affinity-based sorbents in the field of microextraction techniques. The first part of this paper includes an introduction regarding monolithic affinity media and information of different binding agents (such as immunoglobulin-binding proteins, enzymes, lectins, antibodies, aptamers, dyes and immobilized metal ions and nanoparticles, among others) that can act as affinity ligands. Then, the preparation of monoliths and ligand immobilization strategies as well as the different available formats (syringes, pipette tips, spin columns, capillaries, disks an…

ChemistryAptamer010401 analytical chemistryMicrofluidicsNanoparticleNanotechnology02 engineering and technologyLigands021001 nanoscience & nanotechnology01 natural sciencesBiochemistryChromatography Affinity0104 chemical sciencesAnalytical ChemistryHumansEnvironmental ChemistrySample preparationAdsorption0210 nano-technologySolid Phase MicroextractionSpectroscopyAnalytica Chimica Acta
researchProduct

An in-tube SPME device for the selective determination of chlorophyll a in aquatic systems.

2010

We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45m pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl–95% polydimethylsiloxane, 3m coating thickness) was used as the loop of the injection valve for preconcentrati…

Chlorophyll bDetection limitPheophytinChlorophyllQuality ControlChlorophyll aChromatographyExtraction (chemistry)Solid Phase ExtractionAnalytical chemistryPheophytinsSolid-phase microextractionAnalytical Chemistrychemistry.chemical_compoundchemistryLimit of DetectionChlorophyllSolventsSample preparationFiltrationWater Pollutants ChemicalTalanta
researchProduct

Utilization of long duration high-volume sampling coupled to SPME-GC-MS/MS for the assessment of airborne pesticides variability in an urban area (St…

2016

Atmospheric samples have been collected between 14 March and 12 September 2012 on a 2-week basis (15 days of sampling and exchange of traps each 7 days) in Strasbourg (east of France) for the analysis of 43 pesticides. Samples (particle and gas phases) were separately extracted using Accelerated Solvent Extraction (ASE) and pre-concentrated by Solid Phase Micro-Extraction (SPME) before analysis by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Four SPME consecutive injections at distinct temperatures were made in order to increase the sensitivity of detection for the all monitored pesticides. Currently used detected pesticides can be grouped in four classes; those used i…

Chromatography Gas010501 environmental sciences01 natural sciencesGas Chromatography-Mass Spectrometrychemistry.chemical_compoundTandem Mass SpectrometryAcetochlorCitiesPesticides0105 earth and related environmental sciencesFenpropimorphPesticide residueBromoxynilSolid Phase Extraction010401 analytical chemistryPesticide ResiduesSampling (statistics)General MedicinePesticidePollution0104 chemical scienceschemistryEnvironmental chemistryParticulate MatterFranceGas chromatographyGas chromatography–mass spectrometryAgrochemicalsEnvironmental MonitoringFood ScienceJournal of Environmental Science and Health, Part B
researchProduct

Determination of pyrethroid pesticide residues in fatty materials by solid-matrix dispersion partition, followed by mini-column size-exclusion chroma…

1999

The method studied uses a combination of a solid-matrix dispersion partition (SMDP) followed by high-performance size-exclusion chromatography on a minicolumn (HPmSEC) of 7.8 mm I.D. for the separation of pyrethroid (PYR) residues from fatty material. The solid-matrix dispersion extraction is carried out by absorbing a fat solution onto an Extrelut-3 cartridge (filled with a macroporous diatomaceous material) and extracting the PYR residues with acetonitrile. Up to 1 g of fatty material can be extracted with 15 ml acetonitrile. The small amount (mean +/- S.D. = 12.4 +/- 5.9 mg) of fatty material which is eluted into the acetonitrile is further removed by HPmSEC. PYR pesticide residues are c…

Chromatography GasChromatographyPesticide residueChemistryElutionOrganic ChemistrySize-exclusion chromatographyPesticide ResiduesTralomethrinGeneral MedicineReference StandardsBiochemistryAnalytical ChemistryFatsGel permeation chromatographychemistry.chemical_compoundColumn chromatographyPyrethrinsChromatography GelSolid phase extractionGas chromatographyChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Multi-residue determination of organic micro-pollutants in river sediment by stir-disc solid phase extraction based on oxidized buckypaper

2020

This paper describes a procedure for the isolation of 20 organic micro-pollutants among pesticides, drugs, recreational drugs, flame retardants from river sediments. After a solid-liquid extraction with a methanol:water (50:50, v/v) solution, the supernatant was diluted with water and cleaned up by stir-disc solid-phase extraction (SPE). The disc was made of buckypaper, a self-supporting entangled assembly of carbon nanotubes, which was used as a highly porous, two-sided, sorbent membrane. In the preliminary activation step, the membrane was oxidised for 2-hours with nitric acid to extend its extraction capability also to more polar compounds. All extracts were analysed by ultra-high-perfor…

Chromatography Gasdisc-SPESorbentIllicit drugsCarbon nanotubesBuckypaper010402 general chemistryMass spectrometry01 natural sciencesBiochemistrysample preparation disc-SPE organic micro-pollutantsAnalytical Chemistrychemistry.chemical_compoundRiversNitric acidSolid phase extractionOrganic ChemicalsPesticidesSolid phase extractionorganic micro-pollutantsChromatographysample preparationNanotubes CarbonChemistry010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsSedimentGeneral Medicine0104 chemical sciencesOrganic micro-pollutantsSpainSedimentMethanolOxidation-ReductionWater Pollutants Chemical
researchProduct

Evaluation by HPLC-UV of Polar Pesticides in Rice Fields

1999

ChromatographyChemical PhenomenaChemistry PhysicalHealth Toxicology and MutagenesisPesticide ResiduesOryzaGeneral MedicineHydrogen-Ion ConcentrationPesticideToxicologyPollutionHigh-performance liquid chromatographySurface-Active AgentsSpainEnvironmental sciencePaddy fieldPolarSpectrophotometry UltravioletTrace analysisSample preparationSolid phase extractionPesticidesChromatography High Pressure LiquidHalf-LifeBulletin of Environmental Contamination and Toxicology
researchProduct

Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

2016

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The fir…

ChromatographyChemistry010401 analytical chemistryClinical BiochemistryAnalytical chemistryAnalysis of organophosphate flame retardants in water by SPE and UHPLC–MS/MS using a trap column.solid phase extractionWater010501 environmental sciences01 natural sciencesTrap column0104 chemical sciencesOrganophosphate flame retardantsMedical Laboratory TechnologyWastewaterLC–MS/MSLiquid chromatography–mass spectrometryInterferencesLc ms msEnvironmental ScienceGas chromatographyUltra high pressureSolid phase extraction0105 earth and related environmental sciencesComputingMethodologies_COMPUTERGRAPHICSMethodsX
researchProduct

Flow Injection Fourier Transform Infrared Determination of Caffeine in Soft Drinks

1997

A fully automated procedure has been developed for FT-IR determination of caffeine in soft drinks. Samples are first degasified by filtration and then directly injected into a flow manifold and passed through a 100 mg C18 SPE cartridge, conditioned with methanol and water. After the cartridge has been cleaned with water, the caffeine is eluted with CHCl3 and stabilized with ethanol. The flow injection (FI) recording is obtained by measuring the absorbance at 1658 cm-1 with a baseline established at 1800 cm-1. Area values for the FI recording obtained between 0.4 and 1.4 min after sample injection are interpolated in the calibration graph of a series of aqueous standards of caffeine, which w…

ChromatographyChemistryCalibration curveElutionExtraction (chemistry)Analytical chemistryAnalytical Chemistrylaw.inventionAbsorbanceCartridgechemistry.chemical_compoundlawSolid phase extractionCaffeineFiltrationAnalytical Chemistry
researchProduct