Search results for "solut"
showing 10 items of 6365 documents
Portable remote photoplethysmography device for monitoring of blood volume changes with high temporal resolution
2016
The compact remote photoplethysmography device for monitoring of blood volume pulsations from human skin were developed. The prototype device comprises electronics board with twelve circullary oriented bright near-infrared LED illuminators, which are precisely controlled, high-speed video camera and battery charging circuit. Device was tested in laboratory and could be used for non-contact monitoring of human blood volume changes in palm.
Quantitative super-resolution localization microscopy of DNA in situ using Vybrant® DyeCycle™ Violet fluorescent probe.
2016
Single Molecule Localization Microscopy (SMLM) is a recently emerged optical imaging method that was shown to achieve a resolution in the order of tens of nanometers in intact cells. Novel high resolution imaging methods might be crucial for understanding of how the chromatin, a complex of DNA and proteins, is arranged in the eukaryotic cell nucleus. Such an approach utilizing switching of a fluorescent, DNA-binding dye Vybrant® DyeCycle™ Violet has been previously demonstrated by us (Żurek-Biesiada et al., 2015) [1]. Here we provide quantitative information on the influence of the chemical environment on the behavior of the dye, discuss the variability in the DNA-associated signal density,…
Imaging Bacterial Colonies and Phage-Bacterium Interaction at Sub-Nanometer Resolution Using Helium-Ion Microscopy
2017
Imaging of microbial interactions has so far been based on well‐established electron microscopy methods. This study presents a new way to study bacterial colonies and interactions between bacteria and their viruses, bacteriophages (phages), in situ on agar plates using helium ion microscopy (HIM). In biological imaging, HIM has advantages over traditional scanning electron microscopy with its sub‐nanometer resolution, increased surface sensitivity, and the possibility to image nonconductive samples. Furthermore, by controlling the He beam dose or by using heavier Ne ions, the HIM instrument provides the possibility to mill out material in the samples, allowing for subsurface imaging and in …
In vitro comparison of passive and continuous ultrasonic irrigation in curved root canals
2016
BACKGROUND The efficacy of endodontic irrigation procedures can be compromised by the complexity of the root canal system. Delivering irrigants to the apical third of curved canals presents a particular challenge to endodontists. This study compared the effects of two ultrasonic irrigation techniques on the penetration of sodium hypochlorite into the main canal and simulated lateral canals of curved roots in extracted teeth. MATERIAL AND METHODS Two sets of simulated lateral canals were created at 2, 4, and 6 mm from the working length in 60 single-rooted teeth (6 canals/tooth, n = 360 canals). The teeth were randomly divided into three experimental irrigation groups: group 1 (n = 20), posi…
Update of the therapeutic planning of irrigation and intracanal medication in root canal treatment. A literature review
2019
Background The success of endodontic treatment derives from the complete elimination of microorganisms capable of causing an intraradicular or extraradicular infection. To achieve a more effective eradication of these microorganisms, endodontic instrumentation must always be implemented with abundant irrigation, which has to achieve chemical, mechanical and biological effects. The irrigators most used today are NaOCl, CHX and EDTA, released into the ducts through different techniques such as syringe, manual agitation, positive or negative apical pressure, sonic or ultrasonic activation, PIPS and PDT. The objective of this review is to update the different irrigating solutions and intracanal…
Photocage-initiated time-resolved solution X-ray scattering investigation of protein dimerization
2018
Photocaging in combination with X-ray solution scattering allows for the time-resolved study of protein dynamics in solution. This method is versatile and allows for accurate triggering of protein function.
Reply to Comment on: 'Corneal confocal scanning laser microscopy in patients with dry eye disease treated with topical cyclosporine'
2017
Reply to Comment on: ‘Corneal confocal scanning laser microscopy in patients with dry eye disease treated with topical cyclosporine’
A critical evaluation of Amicon Ultra centrifugal filters for separating proteins, drugs and nanoparticles in biosamples
2015
Amicon(®) Ultra centrifugal filters were critically evaluated for various sample preparations, namely (a) proteome fractionation, (b) sample cleanup prior to liquid chromatography mass spectrometry (LC-MS) measurement of small molecules in cell lysate, and (c) separating drug-loaded nanoparticles and released drugs for accurate release profiling in biological samples. (a) Filters of supposedly differing molar mass (MM) selectivity (10, 30, 50 and 100K) were combined to attempt fractionation of samples of various complexity and concentration. However, the products had surprisingly similar MM retentate/filtrate profiles, and the filters were unsuited for proteome fractionation. (b) Centrifuga…
Negatively Charged Gangliosides Promote Membrane Association of Amphipathic Neurotransmitters
2018
Lipophilic neurotransmitters (NTs) such as dopamine are chemical messengers enabling neurotransmission by adhering onto the extracellular surface of the post-synaptic membrane in a synapse, followed by binding to their receptors. Previous studies have shown that the strength of the NT-membrane association is dependent on the lipid composition of the membrane. Negatively charged lipids such as phosphatidylserine, phosphatidylglycerol, and phosphatidic acid have been indicated to promote NT-membrane binding, however these anionic lipids reside almost exclusively in the intracellular leaflet of the post-synaptic membrane instead of the extracellular leaflet facing the synaptic cleft. Meanwhile…
Exome-wide somatic mutation characterization of small bowel adenocarcinoma
2018
Small bowel adenocarcinoma (SBA) is an aggressive disease with limited treatment options. Despite previous studies, its molecular genetic background has remained somewhat elusive. To comprehensively characterize the mutational landscape of this tumor type, and to identify possible targets of treatment, we conducted the first large exome sequencing study on a population-based set of SBA samples from all three small bowel segments. Archival tissue from 106 primary tumors with appropriate clinical information were available for exome sequencing from a patient series consisting of a majority of confirmed SBA cases diagnosed in Finland between the years 2003–2011. Paired-end exome sequencing was…