Search results for "sources"
showing 10 items of 2554 documents
Broadband microwave emission spectrum associated with kinetic instabilities in minimum-B ECR plasmas
2017
Plasmas of electron cyclotron resonance ion sources (ECRISs) are prone to kinetic instabilities due to the resonant heating mechanism resulting in anisotropic electron velocity distribution. Frequently observed periodic oscillations of extracted ion beam current in the case of high plasma heating power and/or strong magnetic field have been proven to be caused by cyclotrontype instabilities leading to a notable reduction and temporal variation of highly charged ion production. Thus, investigations of such instabilities and techniques for their suppression have become important topics in ECRIS research. The microwave emission caused by the instabilities contains information on the electron e…
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
2017
A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…
Charge breeding at GANIL: Improvements, results, and comparison with the other facilities
2019
International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…
Hydrogen plasma induced photoelectron emission from low work function cesium covered metal surfaces
2017
Experimental results of hydrogen plasma induced photoelectron emission from cesium covered metal surfaces under ion source relevant conditions are reported. The transient photoelectron current during the Cs deposition process is measured from Mo, Al, Cu, Ta, Y, Ni, and stainless steel (SAE 304) surfaces. The photoelectron emission is 2–3.5 times higher at optimal Cs layer thickness in comparison to the clean substrate material. Emission from the thick layer of Cs is found to be 60%–80% lower than the emission from clean substrates. peerReviewed
Cyclotron instability in the afterglow mode of minimum-B ECRIS.
2016
It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…
Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities
2015
MonPS16; International audience; The long-term operation of high charge state electron cyclotron resonance ion sources fed withhigh microwave power has caused damage to the plasma chamber wall in several laboratories.Porosity, or a small hole, can be progressively created in the wall on a year time scale, which cancause a water leak from the cooling system into the plasma chamber vacuum. A burnout of theVENUS chamber is investigated. Information on the hole formation and on the necessary localhot electron power density is presented. Next, the hot electron flux to the wall is studied bymeans of simulations. First, the results of a simple model assuming that electrons are fullymagnetized and …
Estimating ion confinement times from beam current transients in conventional and charge breeder ECRIS
2019
International audience; Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms–60 ms with a clear dependence on the ion charge-to-mass ratio—higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used f…
Budyko’s Based Method for Annual Runoff Characterization across Different Climatic Areas: an Application to United States
2018
Runoff data knowledge is of fundamental importance for a wide range of hydrological, ecological, and socioeconomic applications. The reconstruction of annual runoff is a fundamental task for several activities related to water resources management, especially for ungauged basins. At catchment scales, the Budyko's framework provides an extremely useful and, in some cases, accurate estimation of the long-term partitioning of precipitation into evapotranspiration and runoff as a function of the prevailing climatic conditions. Recently the same long-term partitioning rules have been successfully used to describe water partitioning also at the annual scale and calculate the annual runoff distrib…
Using scintillometry to assess reference evapotranspiration methods and their impact on the water balance of olive groves
2016
Abstract Reference evapotranspiration (ET 0 ) is widely used for irrigation scheduling, to promote an efficient use of water resources for a sustainable agro-ecosystem productivity, as well as to manage water quality and to face other environmental concerns. As suggested by ASCE-EWRI and FAO, standard Penman–Monteith methods are generally applied for an accurate estimation of ET 0 from hourly to daily scale. In absence of detailed meteorological information several simplified equations, using a limited number of variables, have been proposed as alternative. In this paper, the performance of different reference evapotranspiration methods, at hourly (Penman–Monteith, Pristley–Taylor, Makkink …
A Search for Ultra-high-energy Neutrinos from TXS 0506+056 Using the Pierre Auger Observatory
2020
Results of a search for ultra-high-energy neutrinos with the Pierre Auger Observatory from the direction of the blazar TXS 0506+056 are presented. They were obtained as part of the follow-up that stemmed from the detection of high-energy neutrinos and gamma rays with IceCube, Fermi-LAT, MAGIC, and other detectors of electromagnetic radiation in several bands. The Pierre Auger Observatory is sensitive to neutrinos in the energy range from 100 PeV to 100 EeV and in the zenith-angle range from θ = 60° to θ = 95°, where the zenith angle is measured from the vertical direction. No neutrinos from the direction of TXS 0506+056 have been found. The results were analyzed in three periods: One of 6 m…