Search results for "stat.ph"
showing 7 items of 7 documents
Novel anti-obesity drugs and plasma lipids
2014
Obesity is a health problem of global, epidemic proportions and a major risk factor for chronic diseases resulting in accelerated morbidity and mortality. Dyslipidemia with a predominance of small dense LDL, impaired functionality of HDL particles, and increased serum levels of remnant particles due to impaired clearance of triglyceriderich lipoproteins significantly heightens cardiovascular events in obese subjects. Pharmacotherapy in combination with lifestyle modification is the primary approach to reduce obesity-related cardiovascular risk. Although there are several potential anti-obesity drugs, orlistat is the only agent that remains available in the market. Lorcaserin and Qsymia ® , …
Status of the EDELWEISS experiment
1999
The Edelweiss Dark Matter Experiment is installed in the Modane Underground Laboratory since 1994. In 1997 the first detector of a 70 g heat and ionization Ge low-temperature detector built by the collaboration showed its discrimination capabilities. During the last two years the installation was upgraded, and a new generation of 70 g Ge detectors is operational. The detector environment is drastically controlled to avoid radioactive contamination. A test run with two new 70 g detectors shows a reduction by a factor of ten in the background level before 7-ray rejection which is now around 2 events/kg/keV/day. Three 320 g Ge cryogenic detectors have been constructed and are now being tested …
Investigation of the magnetic field fluctuation and implementation of a temperature and pressure stabilization at SHIPTRAP
2011
Abstract Penning traps have proven to be powerful tools for the determination of nuclear masses with high accuracy. A crucial parameter for precision mass measurements in Penning traps is the accurate determination of the magnetic-field strength. However, the magnetic field of a superconducting magnet is not constant in time, but changes due to intrinsic effects of the solenoid and external perturbations. These effects have been investigated for SHIPTRAP. Furthermore, a stabilization of the temperature in the magnet bore as well as of the pressure in the liquid-helium cryostat has been implemented. Thus, the magnetic-field related uncertainties have been reduced to 7(6)×10−11/h.
Apoptotic-like Leishmania exploit the host´s autophagy machinery to reduce T-cell-mediated parasite elimination
2015
Apoptosis is a well-defined cellular process in which a cell dies, characterized by cell shrinkage and DNA fragmentation. In parasites like Leishmania, the process of apoptosis-like cell death has been described. Moreover upon infection, the apoptotic-like population is essential for disease development, in part by silencing host phagocytes. Nevertheless, the exact mechanism of how apoptosis in unicellular organisms may support infectivity remains unclear. Therefore we investigated the fate of apoptotic-like Leishmania parasites in human host macrophages. Our data showed--in contrast to viable parasites--that apoptotic-like parasites enter an LC3(+), autophagy-like compartment. The compartm…
Removing krypton from xenon by cryogenic distillation to the ppq level
2017
The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β-emitter 85Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon natKr/Xe<200ppq (parts per quadrillion, 1ppq=10-15mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 · 10 5 with thermodynamic stability a…
Construction, assembly and tests of the ATLAS electromagnetic barrel calorimeter
2006
The construction and assembly of the two half barrels of the ATLAS central electromagnetic calorimeter and their insertion into the barrel cryostat are described. The results of the qualification tests of the calorimeter before installation in the LHC ATLAS pit are given.
The focal plane assembly for the Athena X-ray Integral Field Unit instrument
2016
This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…