Search results for "structures"
showing 10 items of 4815 documents
Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism
2015
Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…
Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up
2014
Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…
Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens
2011
PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Iris-fixated toric phakic intraocular lens for myopic astigmatism
2011
Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
MAGAM II – prospective observational multicentre poisons centres study on eye exposures caused by cleaning products
2019
Objective: Local effects on the eye following cleaning product exposures are frequently reported. According to EU chemicals legislation many cleaning products are labelled with Hazard Phrase 318 in...
Some physiological and psychological characteristics of myopic and non-myopic young men.
2009
As a part of a research project on the health and functional capacity of men at different ages a comparison of selected physiological and psychological characteristics of myopic and non-myopic 31–35 year-old men was made. The random sample studied consisted of 31 myopic and 100 non-myopic men. It was found that the body mass index and fat content were lower among the myopic than among the non-myopic. No significant differences were found in the elastic properties of skin, in blood pressure or in haematological assays studied between the groups. With respect to physical performance it was observed that the myopic had a higher aerobic capacity whereas there were no significant differences in …
Early age of onset, brain morphological changes and non-consistent motor asymmetry in schizophrenic patients.
1999
Previous data suggest abnormalities in the consistence of motor dominance in schizophrenia (e.g. mixed-handedness, poor correlation between hand, eye and foot preferences and an increase of hand-eye crossed dominance). The aim of this work is to examine the clinical significance of hand-eye and hand-foot crossed dominance in a sample of 61 right-handed schizophrenic patients. The application of multivariate analysis revealed that 23 right-handed and non-right-eyed patients (crossed hand-eye dominant group) had a significant earlier clinical onset and smaller brain size, global and frontal area, than 38 right-handed and right-eyed schizophrenics (consistent hand-eye dominance group). These f…
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …