Search results for "structures"
showing 10 items of 4815 documents
The effect of visual focus on spatio-temporal and kinematic parameters of treadmill running
2017
The characteristics of a treadmill and the environment where it is based could influence the user’s gaze and have an effect on their running kinematics and lower limb impacts. The aim of this study was to identify the effect of visual focus on spatio-temporal parameters and lower limb kinematics during treadmill running. Twenty six experienced runners ran at 3.33 m s−1 on a treadmill under two visual conditions, either looking ahead at a wall or looking down at the treadmill visual display. Spatio-temporal parameters, impact accelerations of the head and tibia, and knee and ankle kinematics were measured for the final 15 s of a 90 s bout of running under each condition. At the end of the te…
Vision evaluation in people with Down's syndrome.
1994
We tested the colour vision of 72 people with Down's syndrome using the Ishihara test and an anomaloscope. We found that 13 of the subjects, 6 males and 7 females, had defective colour vision according to Pickford's classification. In monocular vision 10 eyes were protan (five simple, three extreme and two deviant), one eye was simple deuteranomalous and the remaining eyes were normal: in binocular vision four of the subjects were protan (two simple and two deviant), two subjects were deutan (one simple and one deviant) and the rest were normal. Many of our subjects had lens opacities, strabismus, nystagmus, hypermetropia, high myopia and astigmatism, confirming literature reports. The cont…
Upper and lower face apraxia: role of the right hemisphere.
2000
The aim of this study was to evaluate face apraxia in left- and right-hemisphere-damaged patients both in the acute and chronic stage of their disease. Two newly devised tests that assess movements of the upper and lower face districts were employed. On the whole, the proportion of left-hemisphere-damaged patients showing face apraxia were 46 and 68% for upper and lower face, respectively. A substantial proportion of right-hemisphere-damaged patients also showed face apraxia, i.e. 44% upper face and 38% lower face. Concomitant variables such as general severity, locus of lesion, language or visuo-spatial impairments, presence of neglect, interval from stroke, peculiarity of clusters of item…
Inter-hemispheric remapping between arm proprioception and vision of the hand is disrupted by single pulse TMS on the left parietal cortex.
2013
International audience; Parietal cortical areas are involved in sensori-motor transformations for their respective contralateral hemifield/body. When arms of the subjects are crossed while their gaze is fixed straight ahead, vision of the hand is processed by the hemisphere ipsilateral to the arm position and proprioception of the arm by the contralateral hemisphere. It induces interhemispheric transfer and remapping. Our objective was to investigate whether a single pulse TMS applied to the left parietal cortical area would disturb interhemispheric remapping in a similar case, and would increase a simple reaction time (RT) with respect to a control single pulse TMS applied to the frontal c…
Behavioral and event-related potential distraction effects with regularly occurring auditory deviants
2007
When auditory stimulation contains infrequent task-irrelevant changes (deviants), behavioral responses to task-relevant aspects of the stimulation are prolonged. Event-related brain potentials (ERPs) show that deviants elicit mismatch negativity (MMN), P3a, and reorienting negativity (RON). Here, we examine whether distraction effects can also be elicited within fixed auditory sequences with deviant probabilities of 0.25, 0.33, and 0.5. Deviants varied either in pitch, loudness, or sound source location. In all conditions MMN and P3a were elicited, suggesting that an automatic detection of and an attentional allocation to the change occurred. With relative frequencies of 25% and 33%, devian…
Imaging the visual autokinetic illusion with fMRI
2005
During fixation of a stationary, dim light-emitting diode (LED) in complete darkness, a subtle, apparent motion is perceived which is called autokinesis. This autokinetic illusion increases with increasing fixation time. Eleven healthy subjects were examined by fMRI while fixating an LED in darkness for 35 s. BOLD signal changes of the first and the second half of the fixation period were compared. While the stimulus was the same for both periods, perception differed in that autokinesis was more pronounced in the second half. This second half of the period was associated with bilateral activations in the motion-sensitive middle occipito-temporal area known as MT/V5. Our finding suggests tha…
Response repetition vs. response change modulates behavioral and electrophysiological effects of distraction
2004
If stimulation occasionally contains distracting information, behavioral responses to task-relevant aspects of the stimulation are prolonged and more error prone. Additionally, event-related potentials (ERPs) acquired in an auditory distraction paradigm show that the distracting information elicits the components mismatch negativity (MMN), P3a and reorienting negativity (RON). Here, we assess to what extent sequential dependencies in the stimulation influence such indicators of distraction. Data of four experiments were reanalyzed for response repetition and response change trials separately. Behavioral performance on Deviants suggests markedly smaller distraction effects in change compared…
Effects of high doses of toluene on color vision.
1999
High exposure to toluene may cause optic neuropathy and retinopathy, both associated with dyschromatopsia. Another solvent, ethanol, is known to induce acute blue-yellow dyschromatopsia. This study investigated the acute effects of high doses of toluene on color vision. Eight male printshop workers were examined before and after cleaning printing containers with pure toluene. After cleaning, concentrations of toluene in blood were between 3.61 and 7.37 mg/l. Color vision was tested with the Farnsworth panel D-15 test, the Lanthony desaturated panel D-15 test, and the Standard Pseudoisochromatic Plates part 2. For control of possible acute effects, eight workers of a metal-working factory wi…
Correlations between central corneal thickness and general anthropometric characteristics and cardiovascular parameters in a large European cohort fr…
2014
PURPOSE The aim of this study was to evaluate the correlations between general anthropometric features and cardiovascular parameters and central corneal thickness (CCT) in an adult European cohort. METHODS Analysis was based on a Gutenberg Health Study cohort that included 5000 subjects (2540 male, 2460 female), aged 35 to 74 years at enrollment. The participants underwent a standardized protocol with a comprehensive questionnaire; ophthalmic examination (slit-lamp biomicroscopy; autorefractometry; noncontact tonometry; fundus photography; CCT measurements (optical pachymetry); visual field testing; and a thorough general examination focused on cardiovascular parameters, psychosomatic evalu…
Femtosecond laser–assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty
2013
PURPOSE: To assess the visual and refractive outcomes of femtosecond laser-assisted implanta- tion of Ferrara-type intrastromal corneal ring segments (ICRS) in post-penetrating keratoplasty (PKP) eyes. SETTING: Instituto OftalmolFernOviedo, Spain. DESIGN: Cohort study. METHODS: Patients with previous PKP had ICRS implantation after femtosecond laser tunnel creation. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation. The power vector method was used to analyze refractive errors preoperatively and postoperatively. RESULTS: This study enrolled 32 eyes of 30 patients. The mean UDVA (Snell…